Dear: Mr. Fenton,
Florida Power & Light Company
Enclosed is the easement form required by FPL to provide electric service to the above referenced facility, Please complete
the instrument according to the following instructions. DESCRIBE, EXECUTE and RECORD the easement and return a
recorded copy to me. This easement needs to be returned to FPL prior to energizing your proposed facility, Failure to do
so could delay the timely installation of your electric facilities.
Parcel I. D, #: Enter Parcel I. D. # in the upper left portion of the easement form,
Describe Easement:
Use the blank area in the middle of the form to describe the easement. If additional space is required, an Exhibit "A"
attached as a 2"d sheet to the instrument may be used, Metes & bounds may be used but a center line description is
most common. A pictorial view of the easement may also be attached as an Exhibit "A If Exhibit"A" type description is
used, the middle of the form needs to show"See Exhibit "A" ("Easement Area")". Easements are usually 10' in width for
underground and 20' in width for overhead with the FPL facilities installed along the centerline of the easement, FPL
recommends that the easement be described by a surveyor to ensure the description is accurate and correctly
describes the easement area,
Signing and Witnessing:
A. For Individuals: All persons shown on the deed must sign the easement, Enter date in space provided,
Sign on the indicated lines on the right side in the presence of two (2) separate witnesses, who sign on
the lines to the left, and a notary public who completes the acknowledgement forms as described below.
The notary public may be one of the witnesses and if so must sign at the left in the space provided.
B. For Businesses: Enter date in space provided. The President, or Vice -President sign on lines indicated
on the right, filling in their title below, in the presence of two (2) separate witnesses, who sign on the lines
to the left, and a notary public who completes the acknowledgement forms as described below. The
corporate seal must be affixed adjacent to the officer's signatures,
Acknowledgements:
The notary public should legibly fill in all blanks, including state and county of execution, names of
individuals or officers signing and their titles, state or county where empowered to act, expiration date of
commission, fill in the date, sign on line provided, and affix seal adjacent to the signature of the notary
public.
Record the Easement:
If there are any questions with regards to the easement, please call me prior to recording the easement.
Have the easement Recorded at the Miami Dade County Clerks Office, only the unaltered FPL standard
easement form (form 3722) will be accepted by FPL.
If you have any questions, please call me at 305-377-6108,
Sincerely,
Evelyn Abraham
Construction Services
A NEXTera ENERGY Company
Work Request No, 5877199 UNDERGROUND EASEMENT
Sec,_, Twp _ S, Rge E (BUSINESS
This Instrument Prepare By
Parcel I.D. Name:
('Maintained by County Appraiser) Co. Name:
Address:
The undersigned, in consideration of the payment of $1.00 and other good
and valuable consideration, the adequacy and receipt of which is hereby
acknowledged, grant and give to Florida Power & Light Company, its affiliates,
licensees, agents, successors, and assigns ("FPL"), a non-exclusive
easement forever for the construction, operation and maintenance of
underground electric utility facilities (including cables, conduits, appurtenant
equipment, and appurtenant above -ground equipment) to be installed from
time to time; with the right to reconstruct, improve, add to, enlarge, change the
voltage as well as the size of, and remove such facilities or any of them within
an easement described as follows:
see Exhibit A attached
Together with the right to permit any other person, firm, or corporation to attach or place wires to or within any facilities
hereunder and lay cable and conduit within the Easement Area and to operate the same for communications purposes; the
right of ingress and egress to the Easement Area at all times; the right to clear the land and keep it cleared of all trees,
undergrowth and other obstructions within the Easement Area; the right to trim and cut and keep trimmed and cut all dead,
weak, leaning or dangerous trees or limbs outside of the Easement Area, which might interfere with or fall upon the lines or
systems of communications or power transmission or distribution; and further grants, to the fullest extent the undersigned has
the power to grant, if at all, the rights hereinabove granted on the Easement Area, over, along, under and across the roads,
streets or highways adjoining or through said Easement Area.
IN WITNESS WHEREOF, the undersigned has signed and sealed this instrument on 20
Signed, sealed and delivered in the presence of_ Entity Name
mess gna ure) By:
Print Name:
(Witness) Print Name:
Print Address:
(Witness' ' ignature)
Print Name:
(Witness)
STATE OF
before me this _ day of
AND COUNTY OF
of
personally known to me or has produced
(.Type of Identification)
My Commission Expires:
. The foregoing instrument was acknowledged
20_, by _ the
who is
as identification, and who did (did not) take an oath.
Notary Public, Signature
Print Name
EXHIBIT "A" —12 FEET WIDE EASEMENT
LEGAL DESCRIPTION OF AN EASEMENT TO BE GRANTED TO THE FLORIDA POWER
AND LIGHT COMPANY AND LYING IN BETWEEN TWO FP&L VAULTS DESIGNATED
"FPL VAULT (EAST)" AND "FPL VAULT (WEST)" AT ADDRESS 3501 RICKENBACKER
CAUSEWAY AND 3511 RICKENBACKER CAUSEWAY RESPECTIVELY AND LOCATED
AT THE MIAMI MARE\ESTADIUM PROJECT.
A STRIP OF LAND 12 -FEET IN WIDTH AND BEING A PORTION OF SECTIONS) 17
AND 18, TOWNSHIP 54 SOUTH, RANGE 42 EAST OF THE CITY OF MIAMI, MIAMI-
DADE COUNTY, FLORIDA. AND BEING MORE PARTICULARLY DESCRIBED AS
FOLLOWS:
COMMENCE AT THE SOUTHEAST CORNER OF SECTION 17, TOWNSHIP 54 SOUTH,
RANGE 42 EAST, MIAMI -DADS COUNTY, FLORIDA (A FOUND BRASS DISK. IN
CONCRETE MONUMENT INSIDE A 24" DIAMETER CONCRETE LINE HANDHOLE
STAMPED FLORIDA DEPARTMENT OF ENVIRONMENTAL PROTECTION CERTIFIED
CORNER RECORD NO. 70631 AND FILED MARCH 30, 2001), THIS POINT DESIGNATED
AS POINT OF COMMENCEMENT (P.O.C.); THENCE ON A N89°56'49"W BEARING
ALONG THE SOUTH LINE OF SAID SECTION 17 FOR A DISTANCE OF 2649.94 FEET TO
A POINT OF INTERSECTION WITH THE CENTERLINE OF "RICKENBACKER
CAUSEWAY" (A FOUND 1" DIAMETER IRON PIPE IN CONCRETE) AS RECORDED IN
O.R.B, 11434 AT PG. 234 OF THE PUBLIC RECORDS OF MIAMI -DADS COUNTY;
THENCE RUN N45022'07W AS BASIS OF BEARING ALONG THE CENTERLINE OF
SAID "RICKENBACKER CAUSEWAY" A DISTANCE OF 1284.62 FEET TO A POINT;
THENCE RUN ON A N44°37'53"E BEARING FOR A DISTANCE OF 200.00 FEET TO A
POINT (FOUND 1" DISC IN CONCRETE STAMPED CITY OF MIAMI BEING FOUND 0.13
FEET EAST AND 0.37' FEET SOUTH THEREOF) AND BEING THE SOUTHWESTERLY
CORNER OF MAST ACADEMY AS RECORDED IN O.R.B. 14528 AT PG. 664 OF THE
PUBLIC RECORDS OF MIAMI -DADS COUNTY; ALSO BEING A POINT ON THE
NORTHEASTERLY RIGHT-OF-WAY LINE OF SAID "RICKENBACKER. CAUSEWAY;"
ALSO BEING ON THE SOUTHWESTERLY LINE OF A TRACT OF LAND CONVEYED TO
THE CITY OF MIAMI FROM MIAMI-DADE COUNTY AS RECORDED IN O.R,B. 3609 AT
PG. 160 OF THE PUBLIC RECORDS OF MIAMI-DADE COUNTY, FLORIDA;
THENCE RUN ON A N44037'53"E BEARING FOR A DISTANCE OF 39.26 FEET ALONG
THE WESTERLY LINE OF SAID "MAST ACEDEMY" TO A POINT; THENCE RUN ON A
N45022'07"W BEARING FOR A DISTANCE OF 11.68 FEET TO A POINT ALSO BEING
THE SOUTHEAST CORNER OF THE "FPL VAULT (EAST)" STRUCTURE; THENCE RUN
ON A N45028'53"W BEDR-ZG FOR A DISTANCE OF 9.67 FEET TO THE POINT OF
BEGINNING (P.O.B.) OF SAID 12 -FEET WIDE EASEMENT; THENCE RUN S44°37'53"W
FOR A DISTANCE OF 3 9.3 8 FEET TO A POINT INTERSECTING THE NORTHEASTERLY
RIGHT-OF-WAY LINE OF "RICKENBACKER CAUSEWAY; THENCE RUN ON A
N45022'07W BEARING FOR A DISTANCE OF 1836.23 FEET ALONG THE NORTHEAST-
ERLY RIGHT-OF-WAY LINE OF SAID "RICKENBACKER CAUSEWAY TO A POINT;
THENCE RUN N4403753"E FOR A DISTANCE OF 42..33 FEET TO A POINT;
THENCE RUN S45022:'07"E FOR A DISTANCE OF 12.00 FEET TO A POINT;
THENCE RUN S44037'53"W FOR A DISTANCE OF 30.33 FEET TO A POINT;
DATE: 08/31./2015 Page 1 of 3
THENCE RUN S45°22'07"E FOR A DISTANCE OF 1812.23 FEET TO A POINT;
THENCE RUN N44037'53"E FOR A DISTANCE OF 27.43 FEET TO A POINT;
THENCE RUN S45028'53"E FOR A DISTANCE OF 12.00 FEET TO THE POINT OF
BEGINNING (P.O.B.) BINDING AN AREA CONTAINING 0.5217 ACRES MORE OR LESS
AND BEING WITHIN A TRACT OF LAND ALSO KNOWN AS THE "MIAMI MARINE
STADIUM" SITE AND OWNED BY THE CITY OF MIAMI ON VIRGINIA KEY AND
BEING LEASED BY THE CITY OF MIAMI TO MARINE STADIUM ENTERPREISES INC
WITH FOLIO NO. 01-4217-000-0110.
THE CENTERLINE OF THE ABOVE DESCRIBED AREA IS APPROXIMATELY
COINCIDENT WITH THE CENTERLINE OF AN FP&L DUCT BANK AND AS SHOWN IN
THE ATTACHED SKETCH (SHEET 3 OF 3; EXHIBIT "A").
THIS LEGAL DESCRIPTION IS PREPARED BY MPG TECHNICAL GROUP CORP.
MICHAEL CAROZZA, PROFESSIONAL LAND SURVEYOR & MAPPER LICENSE NO.
6955, STATE OF FLORIDA, DATED 08/31/2015, FOR THE MIAMI MARINE STADIUM
PROJECT, CITY OF MIAMI, MIAMI-DADE COUNTY, FLORIDA.
i
MICHAEL CAROZZA, P.L.S. #6955
MPG Technical Group, Corp.
908 SW 141 Avenue
Miami, Florida 33184
Ph. (305) 559-9043, Fax. (305) 559-8914
DATE; 08/31/2015 Page 2 of 3
N
�J
\� SC.a1E: N.T.S,
MIAMI-DADECOUNTY
A\! SEC. 17-18-54-42
y 6
1100+ >1
t' '171
STORY e
C.B.S.
�,�/pap �fi� ��T �� ��4,��,•
cTO/ e4 o ff?
041 �i y
r8� , AOS
j C Y
4
c o
sb'J
4D POINT OF COMMENCEMENT
09 s E CORNER
SECTION 17+1442 —
1
Z.
DISC IN CONC,
AI
?•"a���L MONENT INSIDE 24'0 CONCRETE
LINED HAND HD' E
(FLORIDA GEPA.F?rtilEM pF EM7R0*JfiEPilAL
��So {O✓N �^� PROTECTION CEgTIFIEDCnR)t�P,
'�%�a2, .� e RECOfiDNo.7D791
• y p) 004F FILED AI.4PCH:sD, 2881)
2649,94'(O.R.B, 114:x#, PG.234)
N89°56'49"W 2649.84'(R) j
N89`56'44"W 2650.32'(C) 17 ) 16
"—S OUTH LNEOF 2 21
SECTION 17.7 MINS HIP 64 SMITH,
RANGE42 EAST )
3
EXHIBIT "A"
SKETCH TO ACCOMPANY A
LEGAL DESCRIPTION
MPG TECHNICAL GROUP CORP,
CERTIFICATE OF AUTN. # LB -6932
BY.' MICHAEL CAR022A DATE 908 SW 141St Avenue,
PROFESSIONAL SURVEYOR AND ALIAPPER MbM, Florida 33184
STA TEOFFLORIDA, LS -6965 Ph, (305)559-9043 Fax. (305)559-8914
MrVALO U.NLESS SIGrJEDANOSEIIM') SIZE FSCM NO. DWG NO. rl
A NIA NIA
FIELDDATE; AVGUST3.1st,2015 SCALE N.T.S SHEEN 3OF3