Loading...
HomeMy WebLinkAboutExhibit M - Data and Analysis RQ RDIA (Obsolete)Exhibit M: River Quadrant Residential Density Increase Area Amendments Data & Analysis Background Subject properties: 300, 312, 316, 320, 330, 350, 402 S MIAMI AV, and 18 SW 3 ST The properties are currently designated "Restricted Commercial" on the Future Land Use Map of the Miami Comprehensive Neighborhood Plan. This allows residential density up to 150 dwelling units per acre. The proposed change to the River Quadrant Residential Density Increase Area ("RQ RDIA") would incorporate these properties in their entirety into the RQ RDIA, increasing the allowed residential density to 500 dwelling units per acre. Existing Proposed History When the Residential Density Increase Areas were first incorporated into the Miami Comprehensive Neighborhood Plan in January 1991 with Ordinance 10832, a concurrent ordinance, Ordinance 10833, designated the subject properties as "Central Business District" (`CBD"). Thus, upon adoption, the boundaries dividing the two areas of increased density, the RDIA and the CBD designation were coterminous. In March 2000, Ordinance 11919 the properties were redesignated from "CBD" to "Restricted Commercial", reducing the density for the subject properties from 1,000 dwelling units per acre to 150 dwelling units per acre. Careful research of the ordinances did not provide any accompanying research or evidence providing support for subdividing these properties along the irregular boundaries. Nor was any support found for the dramatic drop in density —a stark drop for the urban core of the city. This map change seeks to redress the irregular boundary of the RQ RDIA boundary and the dramatic drop in density in a manner cohesive with the surrounding areas. RIVER QUADRANT RESIDENTIAL DENSITY INCREASE AREA EXPANSION CONCURRENCY TESTING CONCURRENCY MANAGEMENT ANALYSIS CITY OF MIAMI PLANNING IMPACT OF PROPOSED AMENDMENT TO FUTURE LAND USE MAP PROJECT DETAILS Project: Date: Applicant: Address: RIVER QUADRANT RDIA - 2022 EAR 8/9/2023 City of Miami 300, 312, 316, 320, 330, 350 & 402 S MIAMI AV Boundary Streets: North: South: SW 3 ST MIAMI RIVER Existing Future Land Use Designation: Residential Density: 0.9983 acres @ Assumed Population Proposed Future Land Use Designation: Residential Density 0.9983 acres @ Assumed Population with Increase East: West S MIAMI AV WATERS AV Restricted Commercial DU/acre 418 Persons 150 River Quadrant RDIA DU/acre 1402 Persons 500 149 DUs 499 DUs NEIGHBORHOOD INFORMATION Commission District Office WASD Sewer Pump Station Basin Moratorium? Drainage Subcatchment Basin Overtown Basin 0001-1 NO K-1 RELEVANT MCNP GOALS, OBJECTIVES, AND POLICIES Future Land Use Goal LU-1 Future Land Use Objective LU-1.1 Future Land Use Policy LU-1.1.1 Capital Improvements Goal CI-1.2 Capital Improvements Objective CI-1.2 Capital Improvements Policy 1.2.3, a-g Transportation Objective TR-1.6 Transportation Objective TR-1.5 CONCURRENCY ANALYSIS Increase in Population: 984 RECREATION AND OPEN SPACE MCNP Parks, Recreation, and Open Space Policy PR-1.1.4 requires a 10-minute (1/2-mile) barrier -free walk to a park entrance. Concurrency Test Result: LOS MET POTABLE WATER Level of Service standard: 92.05 GCPD Transmission potential with FLUM change 129,054 Policy PW-1.2.1 Excess capacity assumed to be 2% after change Concurrency Test Result: OK SANITARY SEWER TRANSMISSION Level of Service standard: 141 GPCD Policy SS-1.3.1 Excess capacity: See Note 1 below. Concurrency Test Result: WASD Permit Required STORM SEWER CAPACITY Exfiltration system before change On -site Exfiltration system after change On -site Concurrency Test Result: OK SOLID WASTE COLLECTION Solid waste generation, 1.28 tons/resident/year 1,795 Excess capacity before change 800 Excess capacity after change (995) Concurrency Test Result: OK TRANSPORTATION Level of Service standards in Objectives TR-1.6 and TR-1.7 Concurrency Test Result: SEE NOTES NOTES Permit for sanitary sewer connection must be issued by Miami -Dade Water and Sewer Department (WASD). Excess capacity, if any, is currently not known Assumed population with increase is assumed to be all new residents as permitted by the proposed future land use designation's base density ascribed through the Interpretation of the 2020 Future Land Use Map and associated Correspondence Table. Additional density may potentially be attainable subject to the detailed provisions of applicable land development regulations. Transportation Concurrency is addressed in a separate memorandum provided by the Office of Capital Improvements. Parks, Recreation, and Open Space Level of Service Proposed River Quadrant Residential Density Increase Area Expansion 1ST ST SW 3RD ST 4TH ST 0 125 250 500 Feet Created by: City of Miami Planning Department Date created: August 17, 2023 N:\Planning\GIS\Concurrency Cm"! City Boundary River Quadrant RDIA Q Subject Parcels Parcels I1 City -Owned Park 0.25 Mile Walking Distance 0.25 to 0.5 Mile Walking Distance SE5THST NOTE: Only the Subject Parcels are subject to Parks LOS testing. The River Quadrant RDIA expansion area only captures the Subject Parcels. N W E S Concurrency Management System (CMS) Miami -Dade County Public Schools Miami -Dade County Public Schools Concurrency Management System Preliminary Concurrency Analysis MDCPS Application Number: PH0123080800397 Local Government (LG): Miami Date Application Received: 8/8/2023 11:55:59 AM LG Application Number: 2023 EAR Type of Application: Public Hearing Sub Type: Land Use Applicant's Name: River Quadrant RDIA Expansion Address/Location: 18 SW 3 ST Master Folio Number: 0101130501040 0101130501020, 0101130501010, 0101130501030, 0101130502010, Additional Folio Number(s): 0141370490010, 0141370490011, 0141370610001, PROPOSED # OF UNITS 350 SINGLE-FAMILY DETACHED UNITS: 0 SINGLE-FAMILY ATTACHED UNITS: 0 MULTIFAMILY UNITS: 350 — CONCURRENCY SERVICE AREA SCHOOLS Net Available Seats Seats 1 Capacity Required Taken LOciiiiiik Source Ty M 1361 FREDERICK DOUGLASS ELEMENTARY 0 14 0 NO Current CSA 1361 FREDERICK DOUGLASS ELEMENTARY 56 14 14 YES Current CSA Five Year Plan 6361 JOSE DE DIEGO MIDDLE 52 6 6 YES Current CSA 7791 BOOKER T WASHINGTON SENIOR -8 6 0 NO Current CSA 7791 BOOKER T WASHINGTON SENIOR 0 6 0 NO Current CSA Five Year Plan ADJACENT SERVICE AREA SCHOOLS 7301 MIAMI EDISON SENIOR 787 6 6 YES Adjacent CSA *An Im•act reduction of 32.58% included for charter and ma•net schools Schools of Choice . MDCPS has conducted a preliminary public school concurrency review of this application; please see results above. A final determination of public school concurrency and capacity reservation will be made at the time of approval of plat, site plan or functional equivalent. THIS ANALYSIS DOES NOT CONSTITUTE PUBLIC SCHOOL CONCURRENCY APPROVAL. 1450 NE 2 Avenue, Room 525, Miami, Florida 33132 / 305-995-7285 / concurrency@dadeschools.net CITY OF MIAMI, FLORIDA TRANSPORTATION CONCURRENCY MEMORANDUM Sue Trone, AICP Chief, Community Planning FROM: Collin Worth Transportation Project Manager DATE: FILE: SUBJECT: REFERENCES: ENCLOSURES: August 16, 2023 2022 EAR: River Quadrant RDIA Transportation Concurrency Analysis 2022 EAR: River Quadrant RDIA Based on existing and proposed FLR and density for the applications for the project located at 300/312/316/320/330/350/402 S Miami Avenue, the maximum potential impact as it relates to trip generation was calculated. The proposed FLR and density have the potential to result in an increase of approximately 1,318 daily trips and 91 P.M. peak hour trips Based on this preliminary analysis, additional information is needed to help determine the impact of this application. At the time of redevelopment, a traffic study may be required. The traffic study should include traffic mitigation if significant impacts to operating levels of service are identified. DAILY TRIP GENERATION COMPARISON EXISTING DAILY TRIP GENERATION ITE TRIP GENERATION CHARACTERISTICS DIRECTIONAL DISTRIBUTION BASELINE TRIPS MULTIMODAL REDUCTION GROSS TRIPS INTERNAL CAPTURE EXTERNAL VEHICLE TRIPS PASS -BY CAPTURE NET NEW EXTERNAL TRIPS Land Use ITE Edition ITE Code Scale ITE Units Percent In Out Total Percent MR Trips In Out Total Percent IC Trips In Out Total Percent PB Trips In Out Total In Out G R O U P 1 1 Multifamily Housing (High -Rise) 11 222 149 du 50% 50% 469 468 937 0.0% 0 469 468 937 0.0% 0 469 468 937 0.0% 0 469 468 937 2 3 4 5 6 7 8 9 10 11 12 13 14 15 ITE Land Use Code Rate or Equa 'on Total: 469 468 937 0.0% 469 469 468 937 0.0% 469 469 468 937 0.0% 469 469 468 937 222 Y=3.76*(X)+377.04 PROPOSED DAILY TRIP GENERATION ITE TRIP GENERATION CHARACTERISTICS DIRECTIONAL DISTRIBUTION BASELINE TRIPS MULTIMODAL REDUCTION GROSS TRIPS INTERNAL CAPTURE EXTERNAL VEHICLE TRIPS PASS -BY CAPTURE NET NEW EXTERNAL TRIPS Land Use ITE Edition ITE Code Scale ITE Units Percent In Out Total Percent MR Trips In Out Total Percent IC Trips In Out Total Percent PB Trips In Out Total In Out G R O U P 2 1 Multifamily Housing (High -Rise) 11 222 499 du 50% 50/ 1,128 1,127 2,255 0.0% 0 1,128 1,127 2,255 0.0% 0 1,128 1,127 2,255 0.0% 0 1,128 1,127 2,255 2 3 4 5 6 7 8 9 10 11 12 13 14 15 ITE Land Use Code Rate or Equa on Total: 1,128 1,127 2,255 0.0% 0 1,128 1,127 2,255 0.0% 0 1,128 1,127 2,255 0.0% 0 1,128 1,127 2,255 222 Y=3.76*(X)+377.04 K:\FTL_TPTO\042258128-WO#28 In-house Support \Correspondence\FLUM\August 2023\TRIP GEN 11_Redevelopment 2023 EAR.xlsx: PRINT -DAILY 8/16/2023,10:38 AM IN OUT TOTAL NET NEW TRIPS 659 659 1,318 PM PEAK HOUR TRIP GENERATION COMPARISON EXISTING WEEKDAY PM PEAK HOUR TRIP GENERATION ITE TRIP GENERATION CHARACTERISTICS DIRECTIONAL DISTRIBUTION BASELINE TRIPS MULTIMODAL REDUCTION GROSS TRIPS INTERNAL CAPTURE EXTERNAL VEHICLE TRIPS PASS -BY CAPTURE NET NEW EXTERNAL TRIPS Land Use ITE Edition ITE Code Scale ITE Units Percent In Out Total Percent MR Trips In Out Total Percent IC Trips In Out Total Percent PB Trips In Out Total In Out G R O U P 1 1 Multifamily Housing (High -Rise) 11 222 149 du 56% 44% 35 27 62 0.0% 0 35 27 62 0.0% 0 35 27 62 0.0% 0 35 27 62 2 3 4 5 6 7 8 9 10 11 12 13 14 15 ITE Land Use Code Rate or Equa on Total: 35 27 62 0.0% 0 35 27 62 0.0% 0 35 27 62 0.0% 0 35 27 62 222 Y=0.26*(X)+23.12 PROPOSED WEEKDAY PM PEAK HOUR TRIP GENERATION ITE TRIP GENERATION CHARACTERISTICS DIRECTIONAL DISTRIBUTION BASELINE TRIPS MULTIMODAL REDUCTION GROSS TRIPS INTERNAL CAPTURE EXTERNAL VEHICLE TRIPS PASS -BY CAPTURE NET NEW EXTERNAL TRIPS Land Use ITE Edition ITE Code Scale ITE Units Percent In Out Total Percent MR Trips In Out Total Percent IC Trips In Out Total Percent PB Trips In Out Total In Out G R O U P 2 1 Multifamily Housing (High -Rise) 11 222 499 du 56% 44% 86 67 153 0.0% 0 86 67 153 0.0% 0 86 67 153 0.0% 0 86 67 153 2 3 4 5 6 7 8 9 10 11 12 13 14 15 ITE Land Use Code Rate or Equa on Total: 86 67 153 0.0% 0 86 67 153 0.0% 0 86 67 153 0.0% 0 86 67 153 222 Y=0.26*(X)+23.12 K:\FTL_TPTO\042258128-WO#28 In-house Support\Correspondence\FLUM\August 2023\TRIP GEN 11_Redevelopment 2023 EAR.xlsx: PRINT -PM PEAK HOUR 8/16/2023,10:38 AM IN OUT TOTAL NET NEW TRIPS 51 40 91