HomeMy WebLinkAboutSubmittal-City Manager-BackupSubmitted into the public record for item(s) lit. 11 on 7/22I2D-1, City Clerk 7/20/21 Occupant Loads The purpose of the occupant Toad is to reflect the maximum number of people anticipated to occupy building rooms or spaces at any given time and under all probable situations. • An occupant load is established for use in sizing the means of egress system and in determining thresholds at which additional provisions, such as mandatory sprinklers, become applicable. Calculating an Occupant Load Calculating an occupant Toad of a space consists of acquiring either the net or gross area of the space and dividing it by the occupant load factor listed below in Table 7.3.1.2 assigned to the use. If a space has multiple uses (i.e. kitchen and dining area), then each area shall be calculated using the appropriate occupant load factor assigned to that use in determining the occupant Toad. Occupant Load Certificate An Occupant Load Certificate is required in every room constituting an assembly occupancy and not having fixed seats. This is to assist in avoiding overcrowding. • The sign shall be posted in a conspicuous location near the main exit from the room. • An assembly occupancy is an occupancy used for a gathering of 50 or more persons for deliberation, worship, entertainment, eating, drinking, amusement, awaiting transportation, or similar uses. Establishments that exceed their occupancy load put the public in danger and can lead to delays or the inability of occupants to exit an establishment during an emergency. Crowd managers are required in assembly occupancies and must possess a current training certificate from an approved provider, which has been issued in the last two years. Training is required consisting of understanding crowd management techniques, evaluating projected levels of occupancy and the adequacy of means of ingress and egress, methods of evacuation and movement, procedures for reporting emergencies, understanding safety and security hazards that can endanger public assembly, etc. 12.7l3 Occcspaat Load Piestia _ 12.7L3.1 eery room constituting an assembly occupancy and not hates fixed seats shall hair the occupant led of the room posted in a conspicuous place near the maim exit from the room 12.71.31 Approved signs shall be 1111intRiBEC1 m a legible maanor by the owner or authorized agent 12.7JJJ Signs shall be durable and shall indicate the number of occupants petmimed for each room use_ 9389 Subm-ffaJ-&hMe'-ntyu-5&ku-p Submitted into the public record for item(s) 01.4 on `r 22 ML1, City Clerk 7/20/21 MEANS OF EGRESS 7.213.f= Water Pratectioa. Bwlctne elements shall be used to Mahn water exposure of =2.evater egn:pment 7.213.7t Power and Coatrol Wiring.. Elevator equnornent. devater cotramlicatens. elevator mach-ne room tooii and elevator controller .vain- shall be suppiiied by both normal and standby power Wirt for power and control shall be located and properly prorec ed to ensure a minimum 1 hour of operation in the event ale fire 7.213.S* Communications. Two-way comunrnrrinon s+stems shall be provided between elevator lobbies and 3 central connol point sad between elevator cars and a cenae! control pone. Commuincanons wring shall be protected to ensue a mtremWa ' hour of operation in the ei:enr of ere 7 213_9* Elevator Operation Elevators shall be provided with fire fighters' emergency opera:Ions in accordance with ASI4E A17.1.CS,A E44.. St jer} Cade for c`iat rtor: grid E:calaaor:. 7113_10 Manteasace_ Where an elevator lobby is served by only one eietator car, the elevator evacuation system still have a program of scheduled maintensosce during tares of budding shutdown or low building activity. Repairs shad: be performed w=haa 24 bass of breakdown 7_2.13_11 Earthquake Protection_ Elevators shalt have the capability of orderly shutdowns during earthquakes at Locations where such shutdowns are an option of ASME A17 I CS.A B44. 500 Code for E: errors and E.xer&ror:. 7_21312 Stooge_ Stgna*e shall comply with `. lc., 3 4. 13 Capecits of 3lman of Egress_ 7.31 Occappaat Load. 7.311 Suariear Capacity. 13111 The total capacity of the memos of egress for any story, btdcon!r, tier. or other occupied space shall be sufficient for the occupant load thereof. 7.1_11_1 For other than enthral.; means of egress. where more than toe mesas of egress is required. the means of eetess shall be of such wda and capacity that the loss of stay one means of egress leaves at•auable not less than 50 percemt of the required capacity 7.3.11' Occupant Load Factor_ The ocrupanr load an nay budding or portion thereof ;hall be not less than the number of persons determined oy dividing the floor area assigned to that lase by the occupant road factor for that use as speczned ma Table '.3.1 Figure 7.3 ; _ .3_, apt r:p.tre , Where both gross and net area 5gmes are grata for the same occupancy, calculations shalt be made by applying the gross area true to the grass area of the portion of the building devoted to the nine fca which the gross area 7g7re is specified mad by applying the net area 5.gure to the net area of the portion elite building denoted to the use for which the net area aeure is specified_ 73.13 Occapiat Load increases. 7.3.1J' _1 The occupant load ii airy budding or portion thereof shall be permitted to be increased from the occupant load established for the v*.en use in is orsiance with 3 1.'_ where ail other regarrenaeats of this Coda are also :stet, based on oath increased accupantload. Table 7.3.1.2 Occapata Load Factor Use A.sembly tise Coated, without 5: e: seamg Less catceoaated use Indian fixed seating Bench-ryPe wag Faced Eearpg r'I-a"1r'P macei :Zorn . stack areas reading maws Sw=g Nob. Swimming pool Esecrse rotors wt& equgsruxa Exert is roosts without eSst?ment Stages Lighticg and aces cataraieaiitnes, gridiron l"15mos and ;i:.n:tar thrinag wee Strong nr1; Restates Use (Winer duo below Ccmcenratec S:istness Ir se Alt anffic cannot tower obser anon Les�`s Da* -Care Ux Detredeta and C err: ec tioasl Edict aortal I -se C ESTOeL:i ncs..*torotors:. vocanoA1. looms Health C are Use 4ust neatmem deparunem Seeping departments Ambu atnnt's health use Industrial [ se General and high iniatvial Spectal•parpose incEntrtal Mercantile Use SAYS area do street. floe' Sales area on two or here street avers' Sales area or door below stilt Eon - person)' (m•per oa)' 7net 15 net 1 person III=. Use anther of fixed seats See 121':and 131'_ 100 100 50 net 50 €1wa1S tfa-e) 30 50 15 li net 100 net 11 50 1Cd 50 Hie 1.10 20 set 50 net 240 120 150 100 NA 30 0 3 lei 1 4 net 1 perwn a..5 :meat sett::. Use theater of Erred seats See12.L'' ar►i 13.I." 9.3 9.3 4.11 art 4.0(inferwbee) 21 4.6 1.4 1.4 Wt 93 nee 4.ti 43 +.5 3 1.9 net 4l1 net 93 3.7 21 Submitted into the public record for item(s) 171.'di on 71Z224221, City Clerk 101-76 LIFE SAFETY CODE 7/20/21 Tah1e 7.3.12 (iir:persear (caltpersoar Sales aria on floors above saran Roar: or portions o` floors used melt for Maces Foots ar portions of floor used only par sump. recaninv mad Jarppin-=. ,marl cot Cp211 to ztacer1l Mil hnidirte;' Re adeanal Use lost:s art dorssacces buildmp Baud and cr^e.:arge Storer ['se In storage occxparuies metriconle accnpaotis :a other dun storage and mercantile occupancies so 5.6 See'bumaess use. Set business me.. 30,3 d'.9 lrytS' r.1Caa3 apphcable'a use of space 206 ;Oral 200 500 NA. Not applicable. The occupant load i; the toasimuum probab:e a tar.` a of octhpazis present a aes pine. Sctt>r a_rz amprsec in uoss area viols rt_alu>•d -'nor." 'For the 7-or-pose of detei in z_ occupant ;oad la mertiri.0 a a.^.taactes Mute. Mt to er:cc in the rushed ground :evei streets oa: i5��ct sides. two or mare Emote dicKtly acressibie from Mori (cot uchair97 z~n s ar t r ular back smuts) man. each ;ark foot is permitted to be can:_: red a Ilea f_.aor. The occupant mad .rtor 15 one bog each -k f1 ' re; of pose floor area of saiti space. 'Fir the ptmpose of determining xrtpmr load in inert,: r£°e or-ipanmes with no street Boor, as tuned is ::' 1, hit gait access 'ten rs _ the street br stairs or escalators, the floor at the ;cant of entrance to the =manta (!ccusaray is considered the street floor 'Fa cry food court or odic assem'vi1• are anus :anted as the =2 That are rot included as a portion. of the goes; :easab:e area of the alai buil:hag. the occmanr 'cal calculated based on the occupant :awd'rcta for Scat use as sae ified is : i:':e - _ .: _. The rismuning mad area is not TNa3red ro be assigned an occupant load. 'The portions of tie mall that are considered a pkesman wry and not •teed as ass :eatable area are mot :gutted to be assessed a. occupant :cad based a Ts; is " , 1 L However toms of tress Sac a traL pedestrian wax are respired to be provided for an outman: load determined by dividing the gess leasabie zee of the tnaw: bsn;dirg ,mot me:udty; anchor cares) err dies appropriate lowest whore racibec oc_ rpm .r toad fat tall' tom i._,rre ' 3 1 ;a) or . 7 €'_;. Earl mdtstncAl tenant space is rego:red to Sage means of s=ass to the oat.ide or to rise 1raa.T based on oc..W>ant t i rr-,wed i+ mica the appropriate ocnipanz'mad Attu once Each ir.d virtu: aecfix ware is maimed to hive means of ogees mdepentle t of the mail. 'See A. - _ .._. 100 rya 20' 291 360 360 400 4,50 GrcaEirasa6Marms lf° 1t]Y31 FIGURE 73.12(a) him[ Banding Occupant Load Fartuu, (U.S. Customary Units). uq. a3MMrlari.Owen* rma MM MMrMMrwn BIM RI MO MMMMM MOM BIM MO MMMMMM me rRMEMI arM essaar a coon �� rrrcMMM 81021 sal pry ma reit ORM10 UM* e>ea (re° x 1001.. F'IGI.Titt 7:3.11(b) Man Building Occupant Load Factors (SI Units). 7.3.1) 2 The aMrlacity laamag Jurisdiction shah be permuted to revue au approved aisle, seating. or fixed equipment diagam to siabsmntiate my increase in occupant load and shalt be permuted to require that such a diagram be posted an as approved location. 7314 Exits Serving Bore than Orr Story. Where an east sett -es more than ace storyonly the occupant load of each sway considered individually droll be used in compurmg the required capacity oldie emir at that start, provided that the retlarred Gress capacity of the emit is not decreased in the direction of egress 73.1.5 Capacity from a Point of C owver1ence. Who =tams of eaess from a story aba,.e and a story below converse at an inrermednte story, the caparr-v of the mans of egress from the point of convergence shall be not less than the sum of the requaed capacity of the two means of egess. Submitted into the public record for item(s) DI 4 on 7'/22/Lo21, City Clerk 7/20/21 Process of Acquiring an Occupant Load Certificate Instructions regarding acquiring an Occupant Load Certificate are available on the City of Miami website. Customers will find these instructions by either entering key words, such as "occupant load" into the search bar or can also find this information when acquiring step-by-step instructions when seeking to apply for a certificate of use. The customer will be asked to submit basic information, such as business name, address, CU number, and contact information. Additional directions are included on the site pertaining to how to submit plans electronically and how to access ePlan. Once the plans are uploaded, the Fire Marshal's Office reviews the plans and visits the establishment to verify the plans are accurate. The Fire Marshal's Office then provides a signed Occupant Load Certificate communicating the maximum occupant load for the space, which the customer can download along with the approved plans on ProjectDox, Electronic Plans Review The Fire Prevention Bureau has migrated to issuing occupant Toad certificates using the same electronic plans review platform that is used in the City of Miami permitting process. This was implemented to be consistent with other city departments, allow for easy retrieval of past occupant load certificates and plans, and to provide an improved means for customers to submit plans at any time. • In the past, floor plans and drawings utilized in determining occupant loads were stored as hard copies, which consumed space and were difficult to locate. • Customers are provided with detailed instructions regarding the process in acquiring an occupant load certificate. These instructions are also located on the City of Miami website and. also accessible via search function. An example of the instructions presented on the City of Miami website are included at the end of this document. Current Actions to Assure Compliance with Occupant Loads and Occupant Load Certificates • A public service announcement is in the process of being developed, which communicates the requirement of an occupant load certificate, the importance of assuring maximum occupant loads are not exceeded, and instructions regarding how to acquire a new or revised occupant load certificate. • The Fire Prevention Bureau has been compiling past hard copy occupant load certificates along with all occupant Toads submitted via electronic plans review. Additionally, fire inspectors are visiting assembly occupancies to verify that occupant load certificates are posted, as well as taking photos of them for our records. The goal is to have all maximum occupant loads that are communicated on occupant load certificates easily accessible. Submitted into the public record for item(s) Di. 4- on 7/224202-1 , City Clerk 7/20/21 • Establishments who have lost their occupant load certificate(s) are provided instructions regarding how to acquire a new occupant load certificate. For those occupancies not working to acquire an occupant Toad certificate in a timely manner, a conservative temporary occupant Toad certificate will be provided, • Fire inspectors are visiting assembly establishments during the day and night to ensure maximum occupant loads are being adhered to and will be taking appropriate action when needed. Certificates of Use: Active Assemblies with occupant loads over 200 (Restaurants over 3,000 sqft, all Taverns, all Nightclubs). Additional Found Total Inside 42 12 54 Inside/Outside 10 4 14 Get an Occupant Load Certificate Do you own a place of assembly (restaurant, bar, club, etc.) that hosts more than 5 people in one room, and need an Occupant/Occupancy Load Certificate? If you are opening a new business, renovating a business, changing a business name, and/or applying for a Certif cate of Use, you will not pass your fire inspection without this certificate if applicable. Occupant loads are required for all interior assembly areas and enclosed exterior assembly areas. NOTE If you have been operating without an Occupancy Load Certificate, you will receive a violation and need to complete this process. Once you complete this process, your violation will be removed. Every room constituting an assembly occupancy. and not having fixed seats shall have the occupant Icad of the room postec in a conspicuous place near The main exit from. (Florida Fire Prevention Code 1.20.1.5.10.4). View the Florida Fire Prevention Code LgIviaer 6} for a definition of what constitutes an assembly cccupancy. 68 Contact Us Phone 305-415-1544 Email fph@miamigov.com Location Miami Submitted into the public record for item(s) DI 4- on 7/22/2b21, City Clerk STEPS Collect Documents n order to apply for your Occupant Load Certificate, you will need: • A floor plan/life safety plan CAD drawing to mandatory 1/4" scale (if possible) showing seating and table/bar arrangements witli appropriate travel paths and width measurements for the following: • Between seating. • isle width clearances. • Business name and address must be documented on the plan. • Ail assembly occupancies require gross and net measurements to include measurements and square footage of each room. • All areas must be labeled indicating their use on the floor plan. • Designer/Architect to include all occupant load calculations on the plans. • Door measurements, stairs, and corridor widths shall be included on the plan. • Door measurements, stairs, and corridor widths shall be included on the plan. • Plans are to show all occupant load calculations for the different areas. • Indicate on the plan any life safety equipment, i.e. fire sprinklers, fire alarm, etc. • Panic hardware must be indicated on exit doors with loads of 1J0 or more occupants. • Fire occupant loads must be included for all interior spaces and enclosed exterior spaces. • All assembly occupancies shall provide proof of crowd manager training per NFPA 101:12.7.6. Apply for Certificate Occupant Load Applicatioi 7/20/21 Submitted into the public record for item(s) 191.4 on 7f22, 2f , City Clerk 7/20/21 Upload Documents You will receive an email from ePlan/ ProjectDox to proceed with uploading drawings into ProjectDox. You will need to create an account. If you need help, we have directions for submitting documents and drawings. About ePlan. How to Submit Plans (Drawings) & Documents Electronically Access ePlan/Proiec Await Inspection After your documents have been reviewed, we will reach out to schedule an inspection. Download Certificate After the inspection is complete (assuming you passed), your certificate will be added to your ProjectDox folder and available for download.