Loading...
HomeMy WebLinkAboutExhibit 1ATTACHMENT 1 A TractofLand in Section 39, Township 54 South, Range 41 East, Dade County, Florida, more particular described as follows: Begin at the Southeast Corner of Lot 1, in Block 28, as shown in the Plat of 'HOLLEMAN PARK", as recorded in .Plat Book 8, Page 23, of the Public Records of Dade County, Florida; thence run S37 00'00"E along the Southeasterly extension of the Southeasterly line of said Lot 1 for 53.20 feet to the Point of Beginning of the parcel of land hereinafter described; thence continue S37 00'00"E, along the previously :described lire for 97.00 feet to a Point of Intersection of the Southeasterly Right of Way of l7th Road .with the Northwesterly Right of Way line of Southwest 2nd Avenue; thence run S53 03'00" W along said Northwesterly Right of Way tine of Southwest 2nd Avenue for 100.00 feet to a Paint on said Right of Way line; thence N37 00'00"W for 97.00 feet to a Point; thence N53 03'00"E for 100.00 feet to the Point of Beginning (Cthi th 4Etixmi Juiy 15, 2011 1700 l3rickell Condo, LLC 1701 SW 2 Avenue Miami, FL 33129 Re: Vanegas Subdivision — NewTentative Plat #1777 Located on. the North Side of S.W. 2nd Avenue Westof S.W. 17th Road Ladies and Gentlemen: EXHIBIT 'A" JOHNNY MARTIfsIEZ,;P.E„ City ringer The City Of Miami Plat and .Street Committee, at its meeting of July 7, 2011, approved the abOVe tentative plat subject to the following revisions being made to the tentative plat additional information being provided and/or variances being granted. Please be advised that the processing of your tentative plat cannot proceed unfit these conditions have been satisfied: Ir in the Location Sketch: a) Provide .a larger sletch and more legible. b) Provide a Sectional/Fractional breakdown. c) include Vie most current subdivisions abutting the proposed plat. d) Provide the zoning designations of all properties abutting the propOsed plat 2. in item #4 of thetentative plat application, provide a more complete legal description. 3. Provide Exhibt "A" referenced in the Warranty Deed. 4. Provide a 25 foot comer radius dedication of right of way on the southeast corner of the site, Including curve data. Also, provide the square footage of the external area of the comer radius and:state that the comer radius is to be dedicated aSfight of way. 5. Adjust the square footage of proposed Tract "Ato reflect the dedication of right of way. S. Delete one of the two surveyors notes stating that the sketch is a 'boundary survey" (notes #5 and #14 7, Specify that the Nliarni-Dade County flood criteria is in feet and •specify the source and datum. 13. A letter from Comc.ast is required to determine if any adjustments to their facilities Or easements • are required. G. Verify with .Miami -Dade County that the proposed plat name is acceptable., 10. All encroachments across proposed tracts andfor Jot lines trivet be removed prior to final plat submittal. 11.. An opinion of tititt,, in the'City Of Miami opinion of title form, must be provided at the time ofthe final plat submittal. 12. Csitterit backup documentation will be required for ali who execute the final plat..A resolution for authority to execute documents and a Certificatf., of Good standing from the Secretary of State are required if.applitabte 13_ TentafiVeplatapplication must be made with Miarni-bade County afar receiving approval from the City of Miami Plat and Street Committee. 14. Be advised that an incomplete final plat packageWill not be accepted by the Catty of Miami. It is the OWner'S responsibility to work With his Surveyor and his attorney to assure that everything is in order before submitting the final plat package 1.5. Be advised that if all the requirettienta for scheduling the final plat for City Commission action are not in order, the final plat iviii not be scheduled fora City Commission meeting. 18. •tri the development information, clarify end expand upon the proposed development intent 17 Show the existing underground Utilities:in the abutting roadways. 18. An Opinion of Tits is required for the remnant property located north of the proposed plat 19 Te the proposed plat to the nearest fractional comer and provide a certified comer record of such comer. 20. Provide a tie along the Monument Line and Centerline Of SW. 17th Road and S.W. 2 Avenue, DEPARTMENT OF PUPLICWORKS 444 SW. .?rid Avenue/ Miami, Florida 33130 / (3057476-1200 fFax: (365/ 41B-128 Mailing Address: P.O. Box 330708 Miami, FL 33233-070B 21. Show all fire hydrants within 300 feet of the proposed plat. 22 Create a tree table. Indicate that there are no trees and in the tree descriptions indicate not applicable.' 23. In the development information, also include the square footage being provided for the proposed tract 24. In the development information, correct the number of units that are allowed under the Miami 21 Zoning Code. 25. In the main sketch, extend the west lot line of the proposed tract northward to intersect Lot 1, Block 28 (east property line of Carrillo Subdivision). 26. Provide elevations in the right of way along the back of sidewalk, front of sidewalk edge of pavement and centerline on 25 foot intervals. 27. Specify if the parkways are paved or sodded. 28. Label the tract as `PROPOSED TRACT A. 29. Show the Plat Book and Page of the property located north of the 'not subdivided" parcel (Brickell West View, P.B. 165,Pg.88). 30. Begin the surveyor's certification with "I", not "We.° In addition to the above requirements, you should be aware of the following: 1. State and local laws require the installation of various physical improvements in the public rights -of -way when property is platted. These subdivision improvements include paving, drainage, landscaping, sidewalks, etc. In some cases this could represent a substantial investment on your part. OPTION: The submission of an electronic copy of the tentative plat, in an AutoCAD version, to the City of Miami Public Works Development and Roadway Plans Section will EXPEDITE the preparation and enhance the ACCURACY of the subdivision improvement estimate letter required for the final plat approval. 2. The alteration, relocation or installation of utilities such as storm and sanitary sewers, electric, telephone, water, etc., caused by this plat will be at the property owner's expense. Also, utility easements may be required on the property being platted. 3. A building permit will not be issued on the property being platted until the final plat is recorded or as authorized by City of Miami Code Section 55-10(h). Also, the Certificate of Occupancy for any building construction will be issued only after ail the required subdivision improvements have been completed. 4. Approval for fire flow requirements must be obtained from the Fire -Rescue Department prior to the issuance of a building permit. 5. Additional items must be provided to the City of Miami Department of Public Works before the final prat is submitted to the City Commission for approval. You will be notified in writing as to what these items are after the amount of the bond has been determined for the necessary subdivision improvements. 6. Tentative plat approval is only valid for one (1) year and six (6) months from the date of the Plat and Street Committee meeting at which time it was approved. If you have any questions concerning these requirements, please refer to the attached sheet for the appropriate person to contact. Sincerely, Bribe Ihekwaba, Ph. D, P.E. Director of Public Works NEl LJi-licdt �rq�t r Enclosure: Contact Sheet c: Manuel G. Vera & Associates, Inc, 13960 S.W. 47th Street Miami, FL 33175 Plat and Street Committee Members Surveys Development and Roadway Plans Central '741.111.• Re -Plats Primary Zoning r 500 Foot Buffer M21 ZONE 11 11 T1 Natural Zone T30 Sub -Urban Zone T3R Sub -Urban Zone T40 General Urban Zone T6-8-0 Urban Core Zone T6-12-0 Urban Core Zone T6-24-0 Urban Core Zone 0 Date. June 14, 2012 120 240 400 Feet