Loading...
HomeMy WebLinkAboutExhibit 1Work Request No. 4282235 Sec._, Twp _ S, Rge E Parcel I.D. (Maintained by County Appraiser) Form 3722 (Stocked) Rev. 6/11 UNDERGROUND EASEMENT (BUSINESS) This Instrument Prepared By Name: Co. Name: Address: pg of The undersigned, in consideration of the payment of $1.00 and other good and valuable consideration, the adequacy and receipt of which is hereby acknowledged, grant and give to Florida Power & Light Company, its licensees, agents, successors, and assigns ("FPL"), a non-exclusive easement forever for the construction, operation and maintenance of underground electric utility facilities (including cables, conduits, appurtenant equipment, and appurtenant above ground equipment) to be installed from time to time; with the right to reconstruct, Improve, add to, enlarge, change the voltage, as well as, the size of and remove such facilities or any of them within an easement described as follows: See Exhibit "A" ("Easement Area") Together with the right to permit FPL to attach wires to any facilities hereunder and lay cable and conduit within the easement and to operate the same for FPL's communications purposes; the right of ingress and egress to the Easement Area at all times; the right to clear the land and keep It cleared of all trees, undergrowth and other obstructions within the Easement Area; to trim and cut and keep trimmed and cut all dead, weak, leaning or dangerous trees or limbs outside of the easement area which might interfere with or fall upon the lines or systems of communications or power transmission or distribution; and further grants, to the fullest extent the undersigned has the power to grant, if at all, the rights hereinabove granted on the Easement Area heretofore described, over, along, under and across the roads, streets or highways adjoining or through said Easement Area. IN WITNESS WHEREOF, the undersigned has signed and sealed this instrument on , 20___. Signed, sealed and delivered In the presence of: Print Name: (Witness' Signature) (witness) (WitnessSignature) Print Name: (Witness) Entity Name By: Print Name: Print Address: STATE OF AND COUNTY OF . The foregoing instrument was acknowledged before me this day of 20_, by , the of a ,who is personally known to me or has produced as Identification, and who did (did not) take an oath, (Type of Identification) My Commission Expires: Notary Public, Signature Print Name ZIELSCREPAPION 10' WIDE F.P.L. EASEMENT 6 E,C SCALE r'=300' LOCATION SKETCH SCALE 1"=300' IN SEC. 30, TWP 52S, RGE 40E MIAMI—DADE COUNTY, FL. SW 32ND AV SW 14TH ST 1 TT- I 1 I -H 1 I I 1 1 1 1 1 I I ill SW 15TH STD � I I ( Sr 16TH ST I I I I II' LEGAL DESCRIPTION: A STRIP OF LAND 10.00 FEET IN WIDTH, BEING A PORTION OF TRACT "A", "CORAL GATE PARK", ACCORDING TO THE PLAT THEREOF, AS RECORDED IN PLAT BOOK 64, PAGE 24, OF THE PUBLIC RECORDS OF MIAMI-DADE COUNTY, FLORIDA, MORE PARTICULARLY DESCRIBED AS FOLLOWS: COMMENCE AT THE NORTHWEST CORNER OF SAID TRACT "A"; THENCE NORTH 8927'33" EAST, ALONG THE NORTH LINE OF SAID TRACT "A", FOR 51.00 FEET, THENCE SOUTH 00'00'00" WEST, PARALLEL WITH THE WEST LINE OF SAID TRACT "A", FOR 27.10 FEET TO THE POINT OF BEGINNING OF THE HEREINAFTER DESCRIBED CENTERLINE OF A 10 FEET WIDE STRIP OF LAND, LYING 5.00 FEET ON EACH SIDE OF SAID CENTERLINE; THENCE CONTINUE SOUTH 00'00'00" WEST, FOR 163.86 FEET; THENCE NORTH 86'15'Ol " EAST, FOR 138.44 FEET; THENCE SOUTH 00'31'18" EAST, FOR 286.83 FEET TO THE POINT OF INTERSECTION WITH THE NORTH LINE OF THE SOUTH 5 FEET OF SAID TRACT "A", SAID POINT ALSO BEING THE POINT OF TERMINATION OF THE CENTERLINE OF SAID 10.00 FEET STRIP OF LAND, SAID POINT LIES 144.23 FEET WEST OF THE WEST LINE OF SAID TRACT "A", AS MEASURED ALONG THE NORTH LINE OF SOUTH 5 FEET OF SAID TRACT "A". THE SIDELINES OF THE AFOREMENTIONED STRIP OF LAND SHALL BE LENGTHEN OF SHORTENED AS NECESSARY TO FORM A CLOSED FIGURE AND TO INTERSECT THE NORTH LINE OF SAID SOUTH 5 FEET OF SAID TRACT "A". SURVEYOR'S NOTES: - This site lies in Section 9, Township 54 South, Range 41 East, Miami, Miami -Dade County, Florida. - Tract dimensions shown hereon are based on: i) Sketch of Survey prepared by Campanile & Associates, Inc., Project 14674, Drowino # 4674, bearing o lost revision dote of 04-12-2010. - Bearings shown hereon are based on on assumed meridian and are relerencec' to the west line of Tract "A'; "CORAL GATE PARK" according to the Plot thereof recorded in Plot Book 64, Page 24, of the Public Records of Miami-Dode County Florida, having a Bearing of NO0'00 "00 "E. - The location of hereon described easement was derived from the location of the edge of pavement of proposed parking lot, the location of the proposed transformer, and on instructions provided by client, per Site Plan by ASTOR/NO Architecture Engineering Interior Design / Build, Job / F009473.00, Sheet A0002, bearing a last revision dote of 02-16-10. - Documen' is not complete without all 2 pages. THIS IS NOT BOUNDARY SURVEY NOT VALID WITHOUT THE SIGNATURE AND ORIGINAL. RAISED SEAL OF A FLORIDA LICENSED SURVEYOR, AND MAPPER. BISCAYNE ENGINEERING COMPANY, INC. 529 WEST FLAGLER STREET MIAMI, . FL. 33130 (305) 324-7671 STATE OF FLORIDA DEPARTMENT OF BUSINESS AND PROFESSIONAL REGULATION LB-0000129 ANDREW D. CONNER, PSM, FOR THE FIRM, :ICE PRESIDENT PROFESSIONAL SURVEYOR AND MAPPER NO. 5995 STATE OF FLORIDA Drawing No, :212.2-SS-23 E \SURITY/PROJECIS\79000's179196 LP.L. \OWJ\79196.dwg 1/6/2012 1:J008 PoI ES7 PROJECT: 10' VVIF.P_L_ �ASEF/IESNIi SURVEY DATE: REVISION DATE: N/A 01-06-12 CLIENT NAME: CITY OF MIAMI CAPITAL I. BEC ORDER # 03-80582 DRAWN BY W.H. SHEET 1 OF 2 A BISCAYNE ENGINEERING COMPANY, INC. TEL (305) 324-7671, FAX (305) 324-1700 WWW. BISCAYNEENGINEERING. COM /898 529 WEST FLAGLER ST, MIAMI FL 33130 10' WIDE F.P.L. EASEMENT (3.E.c SCALE >'=49.0' SYMBOLS AND ABBREVIATIONS: P.O.C. - POINT OF COMMENCEMENT P.O.E. - POINT OF BEGINNING P.O. T. - POINT OF TERMINATION P.8 - PLAT BOOK PG. - PAGE SEC. - SECTION TW° - TOWNSHIP F.P.L. - FLORIDA POWER AND LIGHT - CENTER LINE le - MONUMENT LINE P.O.C. NW. CORNER OF N8927'33"E TRACT "A" _ 51.00' - . 3 uJ mo 0 z. o 0 E0 .‹ wz m 60' 20' 35' o-or. oN 0 O 0 In EAST LINE OF TRACT "A" P.0.8. NORTH LINE OF TRACT "A" F.P.L. EASEMENT o-- 10' F.P.L. EASEMENT 138.44' N8615'01 "E TRACT "A" "COPAL GATE PARK" P.B. 64, PG. 24 NORTH LINE OF THE SOUTH 5' OF TRACT "A" 1n in o 4 \-SOUTH LINE OF TRACT "A" N 4 4 4 10' F.P.L. EASEMENT WEST LINE OF 7RACT "A" P.O.T. F.P.L. EASEMENT N89 28'42"E 144.23' _ N5) O N M — Document is not complete without al/ 2 pages. Drawing No.:212.2-SS-23 F.• \SURY£Y\PROJECTS\79000's79196 EP.L. \79I96.dwg I/6/2012 1:30:08 PM ES7 PROJECT: 1 O' VVIEDEE F_P_L_ EASt=1\/1 SURVEY DATE: N/A CLIENT NAME: CITY OF MIAMI CAPITAL DRAWN BY W.H. REVISION DATE: 01-06-12 BEC ORDER # 03-80582 SHEET 20F2 BISCAYNE ENGINEERING COMPANY, INC. TEL (305) 324-7671, FAX (305) 324-1700 r u 1898 529 WEST FLAGLER ST, MIAMI FL 33130 WWW. BISCAYNEENGINEERING. COM