HomeMy WebLinkAboutCRA-R-12-0053 07-30-2012 BackupPALM CONSTRUCTION AND DESIGN GROUP, INC.
CGC No. 1505387
CONSTRUCTION PROPOSAL: ELECTRICAL REPAIRS
TOWN PARK - VILLAGE 1
1680 NW 4th AVENUE
MIAMI, FLORIDA 33136
12491 S.W. 134th Court •Suite 20•Miami, FL 33186• ph: (786) 251-9289 fax: (305) 378-8995
PALM CONSTRUCTION AND DESIGN GROUP, INC.
CGC No. 1505387
Between the Owner: Town Park Village 1 / City of Miami CRA
1680 NW 4th Avenue
Miami, FL 33136
And the Contractor:
Palm Construction and Design Group, Inc.
12491 SW 134th Court #20
Miami, FL 33186
786-251-9289
For the Project located: 1680 NW 4th Avenue
Miami, FL 33136
12491 S.W. 134th Court •Suite 20•Miami, FL 33186• ph: (786) 251-9289 fax: (305) 378-8995
PALM CONSTRUCTION AND DESIGN GROUP, INC.
CGC No. 1505387
February 6, 2012
We are pleased to submit this proposal for construction services on the aforementioned referenced project
located in Miami, Florida.
Palm Construction and Design Group, Inc, will perform the work outlined below:
A. Smoke Alarm Repair
Install interconnected hard wired smoke alarms in all units of each bldg. (i.e. —147 units)
One (1) carbon monoxide alarm next to gas heater area, and the remainder will be regular
smoke alarms
No other smoke alarm work is included in this proposal
B. Electrical Room Repair
Repair electrical rooms for each of the 18 buildings (i.e. — replace all main disconnects, meter
cans, panel boxes, etc.)
Provide new grounding to all electrical meter rooms
Permit all electrical work
No other electrical work is included in this proposal
C. Fire Alarm Installation
Install new fire alarm system per latest fire code on three (3) existing buildings (i.e. —fire alarm
panels, strobe lights, pull stations, horns, etc.)
Prepare and permit engineering/architectural plans and specifications fully detailing the new
fire alarm system
No other fire alarm work is included in this proposal
D. Exclusions
Environmental services (i.e. — abatement, or remediation)
Irrigation or landscaping
Stucco or Painting
Security or police services
Permit fees
No other construction services not specified herein
12491 S.W. 134th Court •Suite 20•Miami, FL 33186• ph: (786) 251-9289 fax: (305) 378-8995
PALM CONSTRUCTION AND DESIGN GROUP, INC.
CGC No. 1505387
Notes:
1. Palm Construction and Design Group, Inc. will furnish all the labor and materials necessary to
complete the alterations and improvements described in herein.
2. Match existing textures and colors, and tiles as close as possible.
3. This proposal is based upon the observation of conditions. Conditions which could not be
known by a reasonable inspection, such as termite damage, hidden water damage, hidden code
violations, or other concealed conditions, may require extra labor or materials.
City of Miami CRA /Owner shall pay Palm Construction and Design Group, Inc. for the performance of
completed work, as authorized and outlined by this agreement. The contract sum is Three Hundred
Twenty Thousand Dollars, ($320.000.00).
Date: Signature:
City of Miami CRA/Owner
Date: 0g/06/20/2 Signature: aw,d Ney'i
cc: Mark Spanioli
File
Palm Construction and Design Group, Inc.
12491 S.W. 134`h Court •Suite 20•Miami, FL 33186• ph: (786) 251-9289 fax: (305) 378-8995
I3JI3urnsInc. dim
outlook International Electric
January 30, 2012
Town Park Village
1680 NW 4Avenue
Miami, FI 33136
Attn: Gladys Estrada
RE: Town Park Village, 1680 NW 4t Avenue
Multi -Family Housing
Electrical Renovation
Please find herewith our proposal in the amount of $326,486.00 to provide the Electrical Renovation
of the above project as below,
This price shall include the following:
• To replace all existing meter centers with new in each of the eighteen (18) buildings. The new
meter centers will need to be installed on the exterior of the building as the new ones will not
be able to fit under the stairs as currently installed.
• To install new main Disconnect switches for each meter centers. Subject to FPL approval.
• To provide new grounding system for each building.
• To provide smoke and carbon monoxide detectors in each apartment.
• To provide Manual Fire Alarm Systems in Buildings 11,13 and 17.
• All necessary electrical installation needed to complete the project in a workman like manner,
• All labor and materials for the complete installation.
• Any deviation from the plan shall constitute an extra above the cost or contract price.
• This proposal shall become an exhibit to the contract.
• All work shall be done in accordance with the Florida Building Code and the National Electrical
Code.
4700I0iscarne C31vc1 Studte 501Miawa, N. 33137 (7fi"ice: 30-572-9It / fax:305-3/24555 Page 1
Please do not hesitate to call if there are any questions.
Yours truly,
Frank Telfort
• Page 2
Electrical +C rmtraeto,:s
Town Park Village PROPOSAL.
Aftn: Gladys 31-Jan-12
1680 NW 4th Ave. l#8G, 33136-1527
Miami, FL 33136-1527
Emu
Marvelous Electric, Inc, shall provide labor, material and related equipment for complete
installation of electrical work as outlined and described in this Agreement. All work shall
be in strict accordance with the below scope of work for Town Park Village.
At 1680 NW 4th Ave. #8G, Miami, FL 33136-1527
Provided Scope of Work Dated: Project Summary 1/11/12,
Duration: 120 Calender Days.
For the sum of: Three Hundred Forty Thousand Dollars and No Cents
$340,000.00
To be paid in progress payments as follows:
Monthly
Including:
Provide and Install Gear for 18 Electrical Room Repairs according to the provided scope of work.
Provide and Install 3 Fire Alarm Systems according to the provided scpoe of work.
Provide and Install 147 Smoke/Carbon Monoxide Detectors according to the provided scope of work.
Excluding:
Engineering is provided by Other.
All existing Feeders (Conduit & Wire) from FPL Transformer to the 18 Electrical Rooms,
Any alteration or deviation from the above specifications involving extra cost will be executed
only upon written approval from Project Manager, and will become anextra charge over and
above the proposal. All agreements are contingent upon strikes, accidents, or delays beyond
our control. Owners will carry fire, tornado and other necessary insurances.
Marvin Tilley 31-Jan-12
Marvin Tilley President Date
Note this proposal my be withdrawn by Marvelous Electric, Inc. if not accepted within 14 days.
The above prices, specifications and conditions are satisfactory and are hereby accepted.
You are authorized to do the work as specified. Payment will be made as outlined above.
Date of Acceptance: Signature:
PO Box 470576
Miami Florida, 33247
Office: 305-693-5804
Fax: 305-691-0204
www.marvelouselectric.com
FL -EC# 0003001
FLAMINGO ELECTRIC INC.
January 31, 2012
Town Park Village
1680 NW 4th Avenue
Miami, FI 33136
Attn: Gladys Estrada
Re: Town Park Village Multi Family Housing Renovations
We are pleased to be able to submit our proposal for the above project. Our proposal
provides for the following,
To Supply and Install.
1. New Main Disconnect Switches for each of the eighteen building as shown on
your site plan.
2, NEW Multi Meter Units under exterior stairs for the each building, with new
multi meter stack units. These will need to be installed on the exterior of the
stairs, replacing the existing units installed under the stairs.
3. The upgrading of the grounding system for each building
4. To install Smoke, Carbon Monoxide and combination Smoke/Carbon
Monoxide Detectors in each apartment within the complex.
5. Manual Fire alarm system for buildings 11, 13 and 17,
6. All material and labor requiredto provide a complete and working system
7. All work done in a workman like manner to the National Electric Code and
Florida Building Code
Total Cost: $348,860,00
20653 NE 7'" Court, Miami, FI 33179. Tel 305 905 8809, email termicserv@msn.com
If there are any questions please feel free to call
Sincerely,
Steve Francois
President
20653 NE 71h Court, Miami, FI 33179, Tel 305 905 8809, email termicserv@msn.com