Loading...
HomeMy WebLinkAboutPZAB Exhibit EMIAMI 21 AS ADOPTED - MAY 2010 EXHIBIT E ARTICLE 4. TABLE 5 BUILDING FUNCTION: PARKING AND LOADING SHARED PARKING STANDARDS SHARING FACTOR Function RESIDENTIAL LODGING OFFICE COMMERCIAL with Function RESIDENTIAL LODGING OFFICE COMMERCIAL The shared Parking Standards Table provides the method for calculating shared parking for buildings with more than one Use type. It refers to the parking requirements that appear in Table 4. The parking required for any two Functions on a Lot is calculated by dividing the number of spaces required by the lesser of the two uses by the appropriate factor from this Table and adding the result to the greater use parking requirement. For instance: for a building with a Residential Use requiring 100 spaces and a Commercial Use requir- ing 20 spaces, the 20 spaces divided by the sharing factor of 1.2 would reduce the total requirement to 100 plus +617 spaces. For uses not indicated in this chart on a mixed use lot a sharing factor of 1.1 shall be allowed. Additional sharing is allowed by Warrant. OFF-STREET PARKING STANDARDS ANGLE OF PARKING ACCESS AISLE WIDTH ONE WAY TRAFFIC SINGLE LOADED ONE WAY TRAFFIC DOUBLE LOADED TWO WAY TRAFFIC DOUBLE LOADED 90 23ft 23ft 23 ft 60 12.8ft 11.8ft 19.3ft 45 10.8ft 9.5ft 18.5ft Parallel 10 ft 10 ft 20 ft Standard stall: 8.5 ft x 18 ft minimum • Driveways shall have a minimum of 10 feet of paved width of a one-way drive and 20 feet for a two-way drive for parking area providing 10 or more stalls. • Pedestrian entrances shall be at least 3 feet from stall, driveway or access aisle. • Allowable slopes, paving, and drainage as per Florida Building Code. • Off-street Parking facilities shall have a minimum vertical clearance of 7 feet. Where such a facility is to be used by trucks or loading Uses, the minimum clearance shall be 12 feet Residential and 15 feet Commercial and Industrial. • Ingress vehicular control devices shall be located so as to provide a minimum driveway of 20 feet in length between the Base Building Line and dispenser. • For landseaping requirements of parking lots, refer to Article 9 and the City of Miami Off-street Parking Guides and Standards. LOADING BERTH STANDARDS T5, T6, CS, CI -HD & CI DISTRICT NOTES RESIDENTIAL* From 25,000 sf to 500,000 sf Berth Types Residential*: 249 200 sf = 10 ft x 20 ft x 12 ft Commercial': 420 sf = 12 ft x 35 ft x 15 ft Industrial***: 660 sf= 12 ft x 55 ft x 15 ft * Residential loading berths shall be set back a distance equal to their length. ** 1 Commercial berth may be substituted by 2 Residential berths *** 1 Industrial berth may be substituted by 2 Commercial berths. Berth Size Loading Berths 420 sf 1 per first 100 units 240 sf 1 per each additional 100 units or fraction of 100. Greater than 500,000 sf Berth Size Loading Berths 660 sf 1 per first 100 units 240 sf 1 per each additional 100 units or fraction of 100. LODGING From 25,000 sf to 500,000 sf From 25,000 sf to 500,000 sf Berth Size Loading Berths 420 sf 1 per 300 rooms 240 sf 1 per 100 rooms Berth Size Loading Berths 420 sf 1 per 300 rooms 240 sf 1 per 100 rooms Greater than 500,000 sf Greater than 500,000 sf Berth Size Loading Berths 660 sf 1 per 300 rooms 240 sf 1 per 100 rooms Berth Size Loading Berths 660 sf 1 per 300 rooms 240 sf 1 per 100 rooms OFFICE COMMERCIAL** INDUSTRIAL*** From 25,000 sf to 500,000 sf From 25,000 sf to 500,000 sf Berth Size Loading Berths Area 420sf 1st 25Ksf-50Ksf 420sf 2nd 50Ksf-100Ksf 420 sf 3rd 100K sf -250K sf 420sf 4th 250Ksf-500Ksf Berth Size Loading Berths Area 420sf 1st 25Ksf-50Ksf 420sf 2nd 50Ksf-100Ksf 420 sf 3rd 100K sf - 250K sf 420sf 4th 250Ksf-500Ksf Greater than 500,000 sf Greater than 500,000 sf Berth Size Loading Berths Area 660 sf 1 / 500K sf Berth Size Loading Berths Area 660 sf 1 / 500K sf IV.20