HomeMy WebLinkAboutCC Exhibit EMIAMI 21
AS ADOPTED - MAY 2010
EXHIBIT E
ARTICLE 4. TABLE 5 BUILDING FUNCTION: PARKING AND LOADING
SHARED PARKING STANDARDS
SHARING FACTOR
Function
RESIDENTIAL
LODGING
OFFICE
COMMERCIAL
with
Function
RESIDENTIAL
LODGING
OFFICE
COMMERCIAL
The shared Parking Standards Table provides the method for calculating shared parking for buildings
with more than one Use type. It refers to the parking requirements that appear in Table 4.
The parking required for any two Functions on a Lot is calculated by dividing the number of spaces
required by the lesser of the two uses by the appropriate factor from this Table and adding the result to
the greater use parking requirement.
For instance: for a building with a Residential Use requiring 100 spaces and a Commercial Use requir-
ing 20 spaces, the 20 spaces divided by the sharing factor of 1.2 would reduce the total requirement to
100 plus T617 spaces. For uses not indicated in this chart on a mixed use lot a sharing factor of 1.1
shall be allowed. Additional sharing is allowed by Warrant.
OFF-STREET PARKING STANDARDS
ANGLE OF
PARKING
ACCESS AISLE WIDTH
ONE WAY
TRAFFIC
SINGLE LOADED
ONE WAY
TRAFFIC
DOUBLE LOADED
TWO WAY
TRAFFIC
DOUBLE LOADED
90
23ft
23ft
23 ft
60
12.8ft
11.8ft
19.3ft
45
10.8ft
9.5ft
18.5ft
Parallel
10 ft
10 ft
20 ft
Standard stall: 8.5 ft x 18 ft minimum
• Driveways shall have a minimum of 10 feet of paved width of a one-way drive and 20 feet for a two-way
drive for parking area providing 10 or more stalls.
• Pedestrian entrances shall be at least 3 feet from stall, driveway or access aisle.
• Allowable slopes, paving, and drainage as per Florida Building Code.
• Off-street Parking facilities shall have a minimum vertical clearance of 7 feet. Where such a facility is
to be used by trucks or loading Uses, the minimum clearance shall be 12 feet Residential and 15 feet
Commercial and Industrial.
• Ingress vehicular control devices shall be located so as to provide a minimum driveway of 20 feet in
length between the Base Building Line and dispenser.
• For landscaping requirements of parking lots, refer to Article 9 and the City of Miami Off-street Parking
Guides and Standards.
LOADING BERTH STANDARDS
T5, T6, CS, CI -HD & CI
DISTRICT
NOTES
RESIDENTIAL*
From 25,000 sf to 500,000 sf
Berth Size Loading Berths
420 sf 1 per first 100 units
240 200 sf 1 per each additional 100 units or
fraction of 100.
Greater than 500,000 sf
Berth Size Loading Berths
660 sf 1 per first 100 units
249 200 sf 1 per each additional 100 units or
fraction of 100.
Berth Types
Residential*: 249 200 sf = 10 ft x 20 ft x 12 ft
Commercial': 420 sf = 12 ft x 35 ft x 15 ft
Industrial***: 660 sf= 12 ft x 55 ft x 15 ft
* Residential loading berths shall be set back
a distance equal to their length.
** 1 Commercial berth may be substituted by
2 Residential berths
*** 1 Industrial berth may be substituted by 2
Commercial berths.
A required Industrial or Commercial loading
LODGING
From 25,000 sf to 500,000 sf
Berth Size Loading Berths
420 sf 1 per 300 rooms
240 200 sf 1 per 100 rooms
Greater than 500,000 sf
Berth Size Loading Berths
660 sf 1 per 300 rooms
249 200 sf 1 per 100 rooms
From 25,000 sf to 500,000 sf
Berth Size Loading Berths
420 sf 1 per 300 rooms
2444200 sf 1 per 100 rooms
Greater than 500,000 sf
Berth Size Loading Berths
660 sf 1 per 300 rooms
249 200 sf 1 per 100 rooms
berth may be substituted by a Commercial
or Residential loading berth, by Waiver, if
the size, character, and operation of the
Use is found to not require the dimensions
specified and the required loading berth
dimension could not otherwise be provided
according to the regulations of this Code.
OFFICE
COMMERCIAL**
INDUSTRIAL***
From 25,000 sf to 500,000 sf
Berth Size Loading Berths
420sf 1st
420sf 2nd
420 sf 3rd
420sf 4th
Greater than 500,000 sf
Berth Size Loading Berths
660 sf 1 /
Area
25Ksf-50Ksf
50Ksf-100Ksf
100K sf -250K sf
250Ksf-500Ksf
Area
500K sf
From 25,000 sf to 500,000 sf
Berth Size Loading Berths
420sf 1st
420sf 2nd
420 sf 3rd
420sf 4th
Greater than 500,000 sf
Berth Size Loading Berths
660 sf 1 /
Area
25Ksf-50Ksf
50Ksf-100Ksf
100K sf - 250K sf
250Ksf-500Ksf
Area
500K sf
IV.20