HomeMy WebLinkAboutArticle II - Project DescriptionOPUS
MAJOR USE SPECIAL PERMIT
PROJECT DESCRIPTION
ARTICLE 11.
Project Description
A. Zoning Ordinance No. 11000
1. Section 1304.2.1 Application forms; supplementary
materials
2. Section 1702.2.1 General Report
3. Section 1702.2.2 Major Use Special Permit Concept Plan
4. Section 1702.2.3 Development Impact Study
•
•
•
•
MAJOR USE SPECIAL PERMIT
1. Section 1304.1.1 Application forms; supplementary materials
(a) Statements of ownership and control of the proposed
development of activity.
The Disclosure of Ownership and Ownership Affidavit are
provided in Article I.
(b) Statement describing in detail the character and intended use
of the development or activity.
The property is located at 1237 Biscayne Boulevard, Miami,
Florida, within Miami's SD-6 Central Commercial Residential
District. The intent of the project is to contribute to the pedestrian -
friendly Performing Arts Center and Museum (Bicentennial) Park
neighborhood set forth by the SD-6 zoning by providing
residential, retail/gallery, restaurant, office loft, fitness and
recreational amenities to the residents as well as the cultural
visitors, neighborhood workers and tourists.
Opus (the "Project") will be situated on the majority of a city block
south of the new Performing Arts Center and north of Museum
(Bicentennial) Park and I-395, with frontage along Biscayne
Boulevard, N.E. 13th Street and North Bayshore Drive. The
project's location on Biscayne Boulevard and adjacent to 1-395
makes the site a landmark location, visible from all four directions.
The elliptical tower and the podium, with its art feature wrapping
all four sides, will provide architecturally significant facades when
viewed from all directions. The site is located at the of the north-
west corner of Museum (Bicentennial) Park with unobstructed
views east and south to the bay, ocean and city. The restaurants,
retail/gallery and lobby will provide continuous commercial
frontage adjacent to the Performing Arts Center along Biscayne
Boulevard and N.E. 13th Street, with pedestrian access from two
sides of the building. The project incorporates a pedestrian -
friendly plaza facing the Performing Arts Center on Biscayne
Boulevard and N.E. 13th Street, which will be paved and
landscaped to tie in with the paving/landscaping plans for the
Performing Arts Center. The residential/office lobby will be
accessed from N.E. 13th Street and the residential elevator lobbies
can also be accessed from the parking garage levels.
: O➢MAIPC➢OCSLMIA M] .15545691 ]
Page I
•
Opus will comprise a 57 story building which will include 408
residential units on 43 levels and 17,160 square feet of
commercial use on three levels, along with 570 parking spaces on
twelve levels. The street level will consist of double height retail
space, the residential/office lobby, building service rooms, FPL
transformer vault and internal parking and loading areas. Level 2
will consist of the parking garage and garage circulation. Levels 3
through 6 will consist of two double -height office loft levels facing
Biscayne Boulevard and N.E. 13th Street and the parking garage.
Levels 7 through 12 will consist of storage and the parking garage.
Level 13 will be the amenity level with a landscaped deck and
open-air pool and residential units. Levels 14 through 56 will be a
variety of residential unit types including two -level loft units, single
level units and penthouse units. Level 57, the roof level, will
consist of building service areas.
The entrance to the parking garage will be through one two-lane
entry located from N.E. 13th Street. Adjacent to the lobby is a
driveway, which serves as a drop-off zone as well as accessing
the interior street level parking/loading area. Adjacent to the
parking garage ramp is an access drive to the loading bays so
that service vehicles circulate entirely within the street without
complicated maneuvering.
Drawings showing the architectural character and location of the
intended uses are included under Tab 6 of the Supporting
Documents.
(c) General location map, showing relation of the site or activity
for which special permit is sought to major streets, schools,
existing utilities, shopping areas, important physical features
in and adjoining the project or activity and the like .
The following exhibits are included with the Major Use Special
Permit Application:
(1) Aerial: Aerial photograph of the surrounding area
indicating the project site.
(2) Area Context Map/Site Aerial: Map of the project area
indicating buildings that surround the site and their
functions.
(3)
:.ODM AIPCAOCSW11 AMlll 554569%1
Location Map: Map of the surrounding street system
indicating the project location.
Page z
•
•
•
(d) A site plan containing the title of the project and the names of
the project planner and developer, date, and north arrow and,
based on an exact survey of the property drawn to a scale of
sufficient size to show:
The general information requested is shown on the Context Plan
(AO.), Site Plan (AO. 3) and Ground Floor Plan (A1.1) provided
under Tab 6 of the Supporting Documents. The site plan includes
the following:
(1) Boundaries of the project, any existing streets,
buildings, watercourses, easements and section
lines;
The boundaries of the Project and the location of existing
streets and easements are shown on the Survey located
under Tab 5 of the Supporting Documents.
(2) Exact location of all buildings and structures;
There are currently no permanent buildings located on the
property, as shown on the Boundary Survey under Tab 5.
The location of the proposed building to be constructed is
shown on the Context Plan, Sheet A0.1, and the Ground
Floor Plan, Sheet A1.1, located under Tab 6 of the
Supporting Documents.
(3) Access and traffic flow and how vehicular traffic will
be separated from pedestrian and other types of
traffic;
Vehicular access for the Project will be from N.E. 13th
Street. A detailed analysis of the site access and traffic
flow is provided in the Traffic Impact Analysis located
under Tab 2 of the Supporting Documents.
The Project can be accessed by pedestrians from
Biscayne Boulevard and N.E. 6th Street. Vehicular curb
cuts have been avoided along Biscayne Boulevard to
provide maximum unobstructed pedestrian activity along
this major artery. The design of the building coordinates
with the corner plaza to create a pedestrian friendly urban
environment.
(4) Off-street parking and off-street loading areas;
::ODMA'.PCDOCS1M1AMA 155456911
Page 3
•
•
(5)
The parking structure will have 570 parking spaces which
will support the entire development. The off-street parking
facility is located within the parking garage, Levels 1
through 12, with internal vehicular circulation. The garage
is shown on Sheets A1.1 through A1.4, provided under
Tab 6 of the Supporting Documents.
The Zoning Ordinance requires four loading bays, each
12 ft. by 35 ft. The project is designed with a total of six
loading bays, two each 12 ft. by 35 ft. and four each 12 ft.
by 20 ft. The vertical clearance for all loading bays is a
minimum of 14 feet. Service areas are shown on the
Ground Level Plan, Sheet A1.1, under Tab..6 of the
Supporting Documents.
Recreational facilities locations;
Open plaza areas are provided on the ground level facing
onto Biscayne Boulevard and N.E. 13th Street and on
Level 13 above the parking garage podium for residential
use. These will serve as recreation areas for the
development and will have outdoor amenities including a
landscaped urban plaza and outdoor cafe for the public
along with a landscaped courtyard, pools and sun decks
for the residential users.
These facilities are shown on the architectural Plans A1.1
and Al. 5 and on the Landscape Plans L1 and L2 under
Tabof the Supporting Documents.
(6) Screens and buffers;
The plaza along Biscayne Boulevard and N.E. 13th Street
will be paved and landscaped to coordinate with City's
plan for the paving and landscaping along the length of
Biscayne Boulevard from Museum (Bicentennial) Park to
the Performing Arts Center. The lengths of the N.E. 13th
Street and North Bayshore Drive frontage will also have
shade trees as indicated on the Architectural and
Landscape Plans located under Tab 6 of the Supporting
Documents.
(7)
ODM_A.PCDQCS;MAIVII, 554569.;
The ground level building service areas and the parking
levels are screened from public view. The tower facade
design is designed to screen the rooftop building service
areas and equipment from view.
Refuse collections areas;
Page 4
•
•
Waste collection will be provided with a fully enclosed
containerized trash system located within the service area
in the building, which is not visible from the street. These
facilities are shown on the Ground Level Plan, Sheet
A1.1, located under Tab 6 of the Supporting Documents.
(8) Access to utilities and points of utilities hookups;
Access and connections to site utilities are discussed in
the Site Utility Study located under Tab 3 of the
Supporting Documents.
(e) Tabulations of total gross acreage in the project and the
percentages thereof proposed to be devoted to:
(1) The various permitted uses;
Gross area: 114,332 square feet = 2.62 acres
Max. developable area: 960,388 square feet
Total proposed area: 467,160 square feet = 48.6% of max.
Residential area: 450,000 square feet = 46.9% of max.
Retail/Restaurant area: 17,160 square feet = 1.8% of max.
Open space required: 45,000 square feet
Open space provided: 45,825 square feet (street level plaza,
open-air amenity deck and enclosed
amenities)
(2) Ground coverage by structures
Ground coverage by the structure is 95.4% of the total gross lot
Area (109,082 square foot building footprint and 114,332 square
foot gross lot area).
(f)
Tabulation showing the following:
(1) The derivation of numbers of off-street parking and
off-street loading spaces shown in (d) above.
The total number of off-street parking spaces required is 430
spaces and the total number of spaces provided will be 570. Of
those totals, the residential uses require 408 spaces and 548
spaces are provided; the non-residential uses require 22 spaces
and 22 spaces are provided. Derivation of the number of off-
street parking is shown on the Site Data and Development
Program located under Tab'6.
(2) Total project density in dwelling units per acre.
:ODMAJCDOCS MIAMI1155456911
Page S
•
•
•
(g)
The Project is providing 408 dwelling units as per the maximum
density of 500 units per acre set forth in the SD-6 Zoning
Ordinance for the Project.
If common facilities (such as recreation areas of structures,
private streets, common open space, etc.) are to be provided
for the development, statements as to how such common
facilities are to be provided and permanently maintained.
All common facilities provided will be maintained initially by the
Owner. Common facilities of the residential tower will be
maintained by a condominium association.
(h) Storm drainage and sanitary sewerage plans.
Storm drainage, water distribution, waste water and solid waste
generation provisions are discussed in the Site Utility Study
located under Tab of the Supporting Documents.
(i) Architectural definitions for buildings in the development;
exact number of dwelling units, sizes, and types, together
with typical floor plans of each type.
The residential tower consists of a total of 488 units, which include
1-Bedrooms, 2-Bedrooms, 1-Bedroom Lofts, 2-Bedroom Lofts and
penthouse units. Typical floor plans for the residential levels are
shown on the Architectural Floor Plans A1.6 through A1.9. All
drawings are located under Tab 6 of the Supporting Documents.
(j) Plans for signs, if any.
Signage for the Project will submitted under separate application.
(k) Landscaping plan, including types, sizes and locations of
vegetation and decorative shrubbery, and showing
provisions for irrigation and future maintenance.
The landscape plans showing vegetation are found on the
Landscape Plans, Sheets L1 and L2. All landscape plans are
located under Tab 6 of the Supporting Documents.
(1) Plans for recreation facilities, if any, including location and
general description of buildings for such use.
Level 13, above the parking garage podium, will provide the
residents with a large area for a recreational room, fitness center
as well as an open-air pool and landscaped sun deck. The raised
ODMA :PCDOCSIMIAMIA I5545591I
Page 6
•
•
•
(m)
cafe terrace and open plaza at street level provide additional
recreational and social gathering opportunities. Plans for these
recreational levels are found on Sheets A1.1 and A1.5.
Such additional data, maps, plans, or statements as may be
required for the particular use or activity involved.
The drawings submitted with this application, which detail the
statistics, floor plans, elevations, sections and renderings for the
Project are provided under Tab 6 of the Supporting Documents.
(n) Such additional data as the applicant may believe is pertinent
to the proper consideration of the site and development plan.
Sections and elevations depicting the architectural character of
the building are shown on the Building Elevations (Sheets A2.1
through A2.4), Sections (Sheets A3.1 and A5.1) and renderings
(Sheets A4.1 and A4.2). All elevations, sections and renderings
are located under Tab 6 of the Supporting Documents.
(o) Lighting Concept Narrative
The lighting scheme will reinforce and accent architectural features
as well as signature elements to create visual interest, enhancing
the dynamic quality of each elevation as seen from the street and
surrounding buildings. In addition, the podium elevations will
incorporate an art feature wall that wraps around all four sides,
providing an artistic contribution to the neighborhood as well as
screening the garage levels.
2. Section 1702.2.1 General Report.
(a) Property ownership and beneficial interest within the
boundaries of the area proposed for Major Use Special
Permit.
Statement of Ownership and beneficial interest within the
boundaries of the area proposed for Major Use Special Permit are
provided in Article I.
(b) The nature of the unified interest or control.
The nature of unified interest or control is indicated in Article; I.
(c) Survey of the proposed area showing property lines and
ownership.
::ODMATC DO CS1MI A M{1155456911
Page 7
•
•
•
A copy of the Surveys are included under Tab 5 of the Supporting
Documents.
(d) Map of existing features, including streets, alleys, easements,
utilities lines, existing land use, general topography, and
physical features.
The existing site features and utility lines are shown on the
Boundary Survey of the property located under Tab 5. The site
features and the utilities are also described in the Site Utility
Study, located under Tab'3 of the Supporting Documents.
(e) Materials to demonstrate the relationship of the elements
listed in (4) preceding to surrounding area characteristics.
(f)
The Drawings Submitted with this Application are located under
Tab 6 of the Supporting Documents.
Existing zoning and adopted comprehensive plan
designations for the area on and around the lands proposed
for Major Use Special Permit.
The existing zoning designation for the property is identified on
Page 36 of the Zoning Atlas Map which is located in Article I,
indicates the existing and surrounding zoning. The zoning
designation for the property is SD-6 Central Commercial
Residential District. The comprehensive plan future land use
designation for the property is Office and Restricted Commercial.
The zoning and the comprehensive plan designation are
consistent with one another.
3. Section 1702.2.2 Major Use Special Permit Concept Plan.
(a) Relationships of the concept plan to surrounding existing
and proposed future uses, activities, systems, and facilities
(transportation, recreation, view corridors, pedestrian
systems, service systems and similar uses.
Section 1(b) contains a written narrative of the Project outlining
proposed uses, activities and architectural character. This
narrative also contains descriptions of the project's relationship to
traffic, pedestrian movements, and transportation access.
Building elevations, sections and perspectives showing the
proposed materials, vertical profile and height, and orientation to
streets are included in the drawings submitted with this
Application. The list of drawings submitted is found under Tab 6
of the Supporting Documents.
ODMA PCDOCSIMIAi 5545691I
Page s
•
(b) Existing zoning and adopted comprehensive plan principles
and designations.
This project conforms to the SD-6 zoning district designations for
this property. The comprehensive plan future land use
designation conforms with the land use designation currently in
effect for this property.
4. Section 1702.2.3 Developmental Impact Study.
(a) A traffic analysis shall be submitted for an area including the
major intersections to be significantly impacted by the site
and other intersections and/ or corridors specified by the City
or the City's consultant.
The Traffic Impact Analysis is included under Tab 2 of the
Supporting Documents.
(b) Economic impact data shall be provided, including estimates
for construction costs, construction employment, and
permanent employment and shall demonstrate that the
proposed development is favorable to the economy, public
services, environment and housing supply of the City.
The Economic Impact Study is included under Tab'; `4 of the
Supporting Documents.
(d) A description of proposed energy conservation measures
shall be provided, including only those measures that are
proposed in addition to the minimum requirements in State
Energy Code.
Architecturally, the building envelope will be comprised of glass,
concrete and the roof. Tinted reflective glass will be used
throughout the building. Electrically, all exterior and landscape
lighting will be controlled by means of time clocks and photocell
switches. Energy saving lamps, ballasts and fixtures are being
considered at cores and public spaces.
(e) Historic Buildings
There are no existing historic structures located on the property.
(f) Environmental Zone
The Property is not located within an environmental preservation
district.
oonna,ICDocs 1AM1115545 911
Page 9
•
•
:ODMA',PCDOCS\MIAMI\ 554569/1
Page to