HomeMy WebLinkAboutMap & Tables- PAB_09.17.08-4th-Streei
NAP Center
• Government
Buildings
Performing
Arts Center /i „
-
American
Airlines
Arena
MAP 1
LOCATION MAP
Miami World
Center Site
Miami Dade
College
0 1 00 2 00 40
0
- -
TABLE 1
PARKINGANDLOADING
This table describes the standards for Parking and Loading. Standards shall include the following:
PARKING STANDARDS
ANGLE OF
PARKING
ACCESS AISLE WIDTH
ONE WAY
TRAFFIC
SINGLE LOADED
ONE WAY
TRAFFIC
DOUBLE LOADED
TWO WAY
TRAFFIC
DOUBLE LOADED
90
60
45
Parallel
23ft.
12.8ft.
10.8 ft.
10 ft.
23ft.
11.8ft.
9.5 ft.
10 ft.
23ft.
19.3 ft.
18.5 ft.
20 ft.
Standard Stall Dimension: 8.5 ft. x 18 ft. minimum
" Driveways shall have a minimum of 10 feet of paved width for a one-way
drive and 20 feet for a two-way drive for parking area providing 10 or more stalls
" Pedestrian entrances shall be at least 3 feet from stall, driveway or access aisle
Allowable slopes, paving and drainage as per Florida Building Code
Off-street parking facilities shall have a minimum vertical clearance of 7 feet,
Where such a facilitiy is to be used by trucks or loading uses, the minimum
clearance shall be 15 feet.
" Ingress vehicular control devices shall be located so as to provide a minimum
driveway of 20 feet in length between the build -to line and dispenser.
" For landscaping requirements of parking lots, refer to Miami -Dade County
Landscape Ordinance.
LOADING BERTH STANDARDS
RESIDENTIAL'
From 25,000 sf to 500,000 sf
Berth Size
420 sf
240 sf
Loading Berths
1 per first 100 units
1 per each additional 100
units or fraction of 100
Greater than 500,000 sf
Berth Size
680 sf
240 sf
Loading Berths
1 per first 100 units
1 per each additional 100
units or fraction of 100
LODGING
From 25,000 sf to 500,000 sf
Berth Size Loading Berths
420 sf 1 per first 300 Rooms
240 sf 1 per 100 Rooms
Greater than 500,000 sf
Berth Size Loading Berths
660 sf 1 per 300 Rooms
240 sf 1 per 100 Rooms
OFFICE
COMMERCIAL
INDUSTRIAL**
From 25,000 sf to 500,000 sf
Berth Size
420sf
420 sf
420sf
420 sf
Loading Berths
1st
2nd
3rd
4th
Area
25Ksf-50Ksf
50K sf - 100K sf
100Ksf-250Ksf
250K sf - 500K sf
Greater than 500,000 sf
Berth Size
660 sf
Loading Berths
1/
Area
500K sf
NOTES
Berth Types
Residential*: 240 sf = 12 ft x 20 ft.
Commercial: 420 sf = 12 ft x 35 ft.
Industrial**: 660sf= 12ftx55ft.
All Berth Types: 15 ft. height clearance
' Residential Loading berths shall be setback
a distance equal to their length.
"' 1 Industrial berth may be substituted by 2
Commercial berths.
TABLE 2
CIVIC SPACE
This table describes the standards for Civic Space. Civic Spaces shall be at ground level, landscaped
and/or paved. Civic Spaces shall be open to the public. Civic Spaces may be publicly or privately
owned.
Square: An open space available for unstructured recreation and civic purposes.
A square is spatially defined by building frontages with streets on at least one
frontage. Its landscape shall consist of pavement, lawns, and trees. Squares
shall be located at the intersection of important thoroughfares. The minimum
size shall be 1/8 acre.
Plaza: An open space available for civic purposes and programmed activities. A
plaza shall be spatially defined by building frontages and may include street
frontages. Its landscape shall consist primarily of pavement and trees. Plazas
shall be located at the intersection of important streets. The minimum size shall
be 1/8 acre.
Courtyard / Garden: An open space spatially defined by buildings and street
walls, and visually accessible on one side to the street.
Playground: An open space designed and equipped for the recreation of children.
A playground shall be fenced and may include open shelter. Playgrounds shall be
interspersed within residential areas and may be placed within a block.
Playgrounds may be included within parks and greens. There shall be no
minimum or maximum size.
Pedestrian Passage: An open space connecting other public space, that is
restricted to pedestrian use and limited vehicular access, of a minimum width of
20 feet. Building walls enfronting a Pedestrian Passage shall have frequent doors
and windows. A Pedestrian Passage may be roofed.
J
TABLE 3 - PAGE 1
BUILDING DISPOSITION
This table describes the standards for Building Disposition. Standards shall include the following:
Building Disposition
Lot Occupation
a. Lot Area
5,000 s.f. min.
b. Lot Width
100 ft. min.
c. Lot Coverage
80% max.
- 1-8 stories
See Regulating Plan
- Above 8th story
18,000 sq. ft. max. floor plate for Residential &
Lodging
30,000 sq. ft. max. floor plate for mixed use,
Office & Commercial & Residential/Office
d. Floor Area Ratio (FAR)
4.32
e. Frontage along build to line
70% min.
f. Open Space Requirements
10% of gross lot area min.
g. Density
300 du/acre max.
Building Setback
a. Building Frontage
See Regulating Plan
c. Side
0 ft. min.; 30 ft. min. above 8th story
d. Rear
0 ft. min.
Building Height
a. Min. Height
2 stories
b. Max. Height
Unlimited
TABLE 3 - PAGE 2
BUILDING DISPOSITION
This table describes the standards for Building Disposition. Standards shall include the following:
BUILDING PLACEMENT
N.T.S.
PARKING PLACEMENT
N.T.S.
FRONTAGE
SIDE SETBACK
FOR Ta'NER
1
101 SLOB SETBACK
I tST LAYER END LAYER L
BUILD -TO LINE
ILL DIMENSION PER REGULATING PLAN
—BACK OF CURB LINE (BCLH
9RDLAYER
FRONTAGE
1ST LAYER
r
2SY LINER
BLO(I. IAN.
2PDLAYER
40 MIN FROM CONKER ~
MIN SIDE SETBACK
BACK CrCURB
LtE xi)
5
f BUILD TO LINE
-5- - -SETBACK
Ti6
LOT LINE
\-SAPS OF CURB
UNE {FM
1110 LAYER
2AliCHITECTIPAL
SCREENING LAYER
PARING IS ALLOWED TO
EXTEND INTO THE 2111,
LAYER IN AREA$ N:TEO
IN THE REGLI AT1NG
PLAN
0' YIN SIDE SETBACK
LOT UNE
BUILD -TO LINE
—BACK OF CURB LINE (BCLH