Loading...
HomeMy WebLinkAboutConcurrency ReportProposal No 06-14 Date: 5/23/06 CONCURRENCY MANAGEMENT ANALYSIS CITY OF MIAMI PLANNING DEPARTMENT IMPACT OF PROPOSED AMENDMENT TO LAND USE MAP WITHIN A TRANSPORTATION CORRIDOR AMENDMENT INFORMATION CONCURRENCY ANALYSIS • Applicant: A. Vicky Garcia -Toledo on behalf of Katia Traikos, Inc Address: 399 NE 82nd Terrace Boundary Streets: North: n/a East: n/a South: NE 82nd Terrace West: NE 4th Avenue Proposed Change: From: Single Family Residential To: Medium Density Multifamily Residential Existing Designation, Maximum Land Use Intensity Residential 2.59 acres @ 9 DU/acre 23 DU's Peak Hour Person -Trip Generation, Residential 33 Other sq.ft. @ FAR 0 sq.ft. Peak Hour Person -Trip Generation, Other Proposed Designation, Maximum Land Use Intensity Residential 2.59 acres @ 65 DU/acre 168 DU's Peak Hour Person -Trip Generation, Residential 137 Other sq.ft. @ FAR 0 sq.ft. Peak Hour Person -Trip Generation, Other 0 Net Increment With Proposed Change: Population 373 Dwelling Units 145 Peak Hour Person -Trips 104 Planning District Little Haiti County Wastewater Collection Zone 308 Drainage Subcatchment Basin C4 Solid Waste Collection Route 2 Transportation Corridor Name NE 2nd Avenue RECREATION AND OPEN SPACE Population Increment, Residents 373 Space Requirement, acres 0.48 Excess Capacity Before Change 182.80 Excess Capacity After Change 182.32 Concurrency Checkoff OK POTABLE WATER TRANSMISSION Population Increment, Residents 373 Transmission Requirement, gpd 83,497 Excess Capacity Before Change >2% above demand Excess Capacity After Change >2% above demand Concurrency Checkoff OK SANITARY SEWER TRANSMISSION Population Increment, Residents 373 Transmission Requirement, gpd 68,959 Excess Capacity Before Change See Note 1. Excess Capacity After Change See Note 1. Concurrency Checkoff WASA Permit Required STORM SEWER CAPACITY Exfiltration System Before Change On -site Exfiltration System After Change On -site Concurrency Checkoff OK SOLID WASTE COLLECTION Population Increment, Residents 373 Solid Waste Generation, tons/year 477 Excess Capacity Before Change 800 Excess Capacity After Change 323 Concurrency Checkoff OK RELEVANT MCNP GOALS, OBJECTIVES, AND POLICIES Land Use Policy 1.1.1 CIE Policy 1.2.3 TRAFFIC CIRCULATION Population Increment, Residents 373 Peak -Hour Person -Trip Generation 104 LOS Before Change B LOS After Change B Concurrency Checkoff OK NOTES 1. Permit for sanitary sewer connection must be issued by Metro -Dade Water and Sewer Authority Department (WASA). Excess capacity, if any, is currently not known rM 1 IN f13/1 t/9r1 ASSUMPTIONS AND COMMENTS Population increment is assumed to be all new residents. Peak -period trip generation is based on ITE Trip Generation, 5th Edition at 1.4 ppv average occupancy for private passenger vehicles. Transportation Corridor capacities and LOS are from Table PT-2(R1), Transportation Corridors report. Potable water and wastewater transmission capacities are in accordance with Metro -Dade County stated capacities and are assumed correct. Service connections to water and sewer mains are assumed to be of adequate size; if not, new connections are to be installed at owners expense. Recreation/Open Space acreage requirements are assumed with proposed change made.