HomeMy WebLinkAboutTAB O - Site Utility StudyLOFTIKA
MAJOR USE SPECIAL PERMIT
SITE UTILITY STUDY
732, L.L.C.
7213 NW 12 Street
Miami, FL 33126
SRS Engineering, Inc.
14160 Palmetto Frontage Road
Suite 22
Miami Lakes, FL 33016
Tel: (305) 817-3393
SRS Engineering, Inc.
Site Utility Study
Introduction
14160 Palmetto Frontage Road, Suite
22 Miami Lakes, Florida 33016-1506
Tel: 30 5-817-3393
Fat: 305-817-339d.
www.srs.corp.coin
Loftika is a proposed mix -use retail/office/residential development to be located north of NW 7th
Street between NW 32nd Place and NW 33rd Avenue, on approximately one and one half acre, in
the City of Miami, Miami -Dade County, Florida (see Attachment "A" Site Location Map).
Currently, three one story residential units, and two other buildings exist on the site, all of which
are to be demolished as part of this project. The Loftika project includes a 13 story residential
tower and a parking garage. The development will consist of a total of 183 residential apartment
units, 14,871 SF office, 11,313 SF Retail and approximately 470 parking spaces. See Table 1,
below for further details of the proposed project.
Table 1:
Project Summary
Occupancy
Units
Floor Area (sfj
Residential
183
179,479
Office
14,871 sf
14,871
Retail
11,313 sf
11,313
Non -FAR
274,267 sf
274,267
Parking
470 spaces
-
Total
-
479,930
Engineering
EB-00007317
May 9, 2006
Page 2
I. Drainage
Existing Drainage
Presently, the site is developed with five one story buildings with associated asphalt parking
areas, and green areas. The existing drainage system will be demolished and a new stormwater
management system will be constructed to retain the runoff generated by the proposed
improvements, as required by code (see below).
Proposed Drainage System
The drainage system for the proposed development will consist of exfiltration trench to facilitate
on -site disposal of storm water runoff. The 5-year design storm water management system, in
accordance with Section D-4, "Water Control", of Part 2 of the Miami -Dade County Public
Works Manual.
Based on preliminary calculations, it is anticipated that six (6) catch basins connected to a total
of 75 linear feet of exfiltration trenches will provide sufficient capacity to dispose of the design
5-year 24-hour storm water runoff generated by the proposed development. Preliminary drainage
computations for the project areas are provided in Attachment "B" Preliminary Drainage
Calculations, which includes the basis for design.
The final drainage design for the project should be in conformance with the requirements of the
Miami -Dade County DERM Water Control Section. Florida Department of Environmental
Protection and other local, state and federal regulatory agencies having jurisdiction over the
proj ect.
II. Water Distribution System
The public water distribution system that would serve the project is owned and operated by the
Miami -Dade Water and Sewer Department (MDWASD). Existing water mains in the vicinity of
the project are shown below in Table 2.
Table 2:
Existing Water Mains
(Per MDWASD Water Atlas Sheet)
Locatio
Between
Tatei
am
NW 7th Street
NW 32nd Place and NW 33rd Avenue
12" D.I.
NW 32nd Place
East side of property
12" D.I. &
4" D.I.
NW 33rd Avenue
West side of property
8" D.I.
Miami -Dade Water and Sewer Department (MDWASD) criteria normally require developers to
SRS Engineering, Inc.
May 9, 2006
Page 3
construct a new 12-inch ductile iron (DI) water main along the frontage of the property.
Currently, a 12-inch water main fronts the property along the NW 7th Street and NW 32"d Place.
A final determination of the points of connection and requirements will not be provided by
MDWASD until a Water and Sewer Agreement is requested by the owner. Water service meters
will be installed by MDWASD forces at the owner's expense.
See Attachment "C" for a copy of the MDWASD water atlas sheet for the project area.
III. Sanitary Sewer Collection System
Table 3 depicts the sanitary sewer mains owned and operated by Miami -Dade Water and
Sewer Department (MDWASD), within the vicinity of the project.
Table 3:
Existing Sanitary Sewer Mains
(Per MDWASD Water Atlas Sheet)
.ocation
Sewer Mains)
NW 7th Street
NW 32nd Place and NW 33rd Avenue
10" Gravity Main
NW 32nd Place
East side of property
10" Gravity Main
NW 33rd Avenue
West side of property
10" Gravity Main
Similar to the water main, an agreement with Miami -Dade County Water and Sewer Department
(MDWASD) will be required for final determination of the points of connection. Public
improvement requirements will not be provided by MDWASD until a Water and Sewer
Agreement is requested by the owner. The proposed on -site sanitary sewer system for the
property can be connected to the either of the existing mains abutting the property; provided that
the line has capacity to handle the existing flows plus the additional flows contributed by the
proposed project. MDWASD may require upgrades to the sanitary sewer system, but this can
not be determined without a request for a water and sewer agreement. A copy of the MDWASD
Sewer Atlas sheet has been attached (See Attachment C).
The flows from the existing MDWASD gravity sanitary sewer mains abutting the property are
received by MDWASD Regional Pump Station #117, located within the center median on NW
35th Court and NW 11th Street. As of April 2006, this pump station is operating under capacity as
established by the USEPA, and is not under any type of moratorium (See Attachment "D" Pump
Station Monthly Information). At this time, it is not anticipated that any improvements to the
regional pumping and/or transmission systems will be required to connect the proposed project.
SRS Engineering, Inc.
May 9, 2006
Page 4
However, a final determination regarding the status of the existing transmission system and the
need for possible improvements will not be made until construction plans are submitted to the
Miami -Dade County DERM Wastewater Section and a Sanitary Sewage System Capacity
Certification Letter is issued.
The flows created by this project have been determined and are shown in Table 4.
Table 4:
Water & Sewer Flow Generation
Type of Occupancy
Total Average
Daily Flow (gpd)
Apartments
183 units
200 end/unit
36,600
Office
14,871 sf
10 d/100 sf
1,487
Retail
11,313 sf
5 gad/100 sf
566
Total Anticipated Flow
38,653 gpd
IV. Solid Waste Generation
Solid waste generated by this project will be collected in standard on -site containers for refuse
and recyclables. Regular pick-up service will be provided by private hauling companies and/or
by the City of Miami Solid Waste Department, who will transport the waste of Miami -Dade
County's or private disposal and recycling facilities. The volumes of solid waste projected to be
generated by the project are shown in Table 5.
Table 5:
Solid Waste Generation
Type of Occupancy
Quantity
tTsage Rate
Total Solid Waste
Generated
SRS Engineering, Inc.
Apartments
183 units
5 lbs/unit/day
0.46
May 9, 2006
Page 5
Office
14,871 sf
6 lbs/1000 sf/day
0.04
Retail
11,313 sf
6 lbs/1000 sf/day
0.03
Total Anticipated Solid Waste Generated
0.53
Sys
SRS Engineering, Inc.
Attachment A
Site Location Map
FORS
SRS Engineering, Inc.
1[1_ Ow 1 F.t Fi
,4
4.
z
e
' 4")
0
k.aCa
(pa -
Nw
-. r‘14 •Yeit t14:tt ii
.1-....
..,,c.10 rit ' Se 8thSt z
V
--, !l-
,,I, a f7.. ..... GI
i- t.:,r- ,,7 - , ,•,,,, 7.171 7.4 •—r. 7
i- 7,
...,
P
1,73 o Nw 36th St >
- —
— ,-;
a' Nw 24:th gt
i 7.717.tf R(*)
LILIG Rd
Nw 21ut
1
11,t, Nv 3:3rd no,
/43. ._
NNW)/2/.:LI51 1St. `21q, F L'41
Nw 25th St Nw 2.51h
Nw 22r., Li SI
Nw 21st St'
Alla pa tta h
1,irpatNEI'v4v1'.'t St Part /-'xPY
Nw
Nw 4711 St
1\1 VO 51:11
*9
Nw 29th St
Nw 26th St
23rd St
7 IQ.
Nw 1911 SI
4 74
a._
Nw 1 itti St "0 rge m zi I.
..., 0 _
N. ro
Nw lii.th St
Nv 15111 St ,
71
[ a.. Nw 1401 St
Nw 911, St
rw 7th St
Nw blh St
N•s,o AO I r'r
6i
Nw I Lit SI
ca
7:z
fr,
- a,
kittAllii A
72,ara 'fifilay
A ktat6oaAv4
NI.; 12th Tor
jtr,840- - - ' .
z
7
V- 7' Z ''• t,0
fl:
,..r. .`• C: 7'
—4 ,CA t 0
= x:.
cx
= X.' 0 • J r% ,,
SP
71 ch
:Nw 3rd SI
-IL ._1. — n L-
i,
-T t
.,.. ) ,...., 17
Nw 2nci St
%.i,
F agyer St --- ---i .-, at
— ..
7.'
20,4 Sid ft-A ' -- l
R
....... , :p.
-: ,;....
sw .51) st t
Sw 7th
5111
',41.11 St
s'y 1 i't
Nw 1Gt tor
Nw 7th St
Nw MI
Vtil Flag
61 (4' Sw 1St St
•_ Sw2r it]
()
St If
9'h St
S'w 21st Si
s 22nd St
..
Mica•IsKitr,
Silver Muff Estates
Btlaroot WaY ' d St
evilla it'Nu 24111 St The Pines
2.bith St
251AiTer '31
Shenandoah 7.P
"c• ''cV4
cov,-At
972 3
kr\
CO
c<ti:Y.
PIN
h._
SRS Engineering, Inc.
14160 Palmetto Frontage Road, Suite 22
Miami Lakes, Florida 33016
Tel: (305) 817-3393
Fax: (305) 817-3394
LOFTIKA
SITE LOCATION MAP
Attachment B
Preliminary Drainage Calculations
klalS
SRS Engineering, Inc.
IV
Serralta Rebull Serig, Inc.
ENGINEERING
1160 Palmetto Frontage Rd.
Miami Lakes, Florida 33016
Tel: (305) 817-3393
Fax: (305) 817-3394
CONSTRUCTION
PROJECT: LOFTIKA
PROJECT NO.: E-0617
FILE NO: E-0617 BAS 1
COMPUTED B`r E.N. DATE: 05/08/06
CHECKED BY: O.S. DATE:
DRAINAGE CALCULATIONS BASIN - 1
GIVEN:
TOTAL AREA
IMPERVIOUS AREA
PERVIOUS AREA
IMPERV. COEFFICIENT
PERVIOUS COEFFICIENT
RUNOFF COEFFICIENT (C)
DESIGN WATER TABLE (October)
FLOOD CRITERIA
INLET GRATE ELEVATION
TRENCH BOTTOM ELEV.
PVMNT SECTION DEPTH
SAFETY FACTOR
HYDRAULIC CONDUCTIVITY AVG. (K)
(SEE ATTACHED TESTS)
WIDTH bottom =
TRENCH SLOPE =1 VERT. TO
INVERT PIPE ELEVATION
DRAINAGE PIPE DIAMETER
CALCULATED
5.00
1.42
1.08
0.34
0.90
0.30
0.76
3.00
5.50
11.60
-3.40
1.50
2
5.00E-05
4.00
0.00
7.60
1.50
[YEARS]
[ACRES]
[ACRES]
[ACRES]
[CONST]
[CONST]
[CONST]
[FEET ABOVE NGVD]
[FEET ABOVE NGVD]
[FEET ABOVE NGVD, LOWEST]
[FEET, NGVD]
[FEET]
[CONST](a safety factor of 2 is built in to the formula)
[CFS/SF/FT OF HEAD] 01.3SUMED,
[FEET]
[HORZ.]
[FEET ABOVE NGVD, LOWEST]
[FEET]
H2 =
Du =
Ds
Wavg =
STORAGE AREA =
Saturated condition STORAGE VOLUME =
Q/LF = k((2 H2 Du)-(Du)^2+(2 H2 Ds))+.000139WDu ACTUAL Q/LF =
DESIGN Q/LF =
TOTAL TRENCH LENGTH (TRY?)=
TOTAL NUMBER OF INLETS =
2.3
1
LF
EA
MINIMUM TRENCH LENGTH PER INLET =
TOTAL STORAGE VOLUME (S) =
ACTUAL EXFILTRATION =
DESIGN EXFILTRATION =
8.6 FT
7.1 FT
6.4 FT
4 FT
15.08 SF
15.08 CU.FT./L.F.
0.013 CFS/L.F OF TRENCH
0.007 CFS/L.F OF TRENCH
(TRENCH PROVIDED = 25
LF.
25 LF
346.92 CU.FT.
0.30 CFS
0.15 CFS
DESIGN CURVES FOR A 5-YR FREQUENCY STORM
(MIAMI)
DRAINAGE CALCULATIONS BASIN -
TIME
[MIN]
(t)
INTENSITY
[IN/HR]
(i)
INFLOW
[CFS]
(Q=CIA)
INFLOW
CUMULATIVE
[CU. FT.]
(Q=CIA)
STORAGE
[CU. FT.]
(S)
ADJUSTED
INFLOW
[CU. FT.]
(Q-S)
ACTUAL
EXFILTRA.
[CU. FT.]
OVERFLOW
[CU. FT.]
(Ponding)
0
0.5
5
10
15
20
25
30
40
50
60
90
120
150
180
0.00
6.80
6.70
6.20
5.55
5.20
4.70
4.40
3.80
3.50
3.25
2.55
2.20
1.80
1.60
0.00
7.30
7.19
6.65
5.96
5.58
5.04
4.72
4.08
3.76
3.49
2.74
2.36
1.93
1.72
0
219
2157
3992
5360
6696
7565
8499
9787
11268
12555
14777
16998
17384
18543
347
347
347
347
347
347
347
347
347
347
347
347
347
347
347
-347
-128
1810
3645
5013
6349
7218
8152
9440
10921
12208
14430
16651
17037
18196
0 0
4 0
45 1765
90 3555
135 4878
180 6169
225 6994
270 7882
360 9080
450 10471
540 11669
810 13620
1079 15572
1349 15688
1619 16577
INFLOW (CU.FT.)
20000
18000
16000
14000
12000
10000
8000
6000
4000
2000
0
DESIGN CURVES (5-YR FREQ.)
50
100
TIME (MIN.)
150
-fr-INFLOW CUMULATIVE (CU.FT.) -0-- ADJUSTED INFLOW (CU.FT.)
-0-ACTUAL EXFILTRATION (CU.FT.) -0-OVERFLOW (CU.FT.)
200
vir
4�
et
VW
Serralta Rebull Serig, Inc.
4160 Palmetto Frontage Rd.
Miami Lakes, Florida 33016
Tel: (305) 817-3393
Fax: (305) 817-3394
ENGINEERING CONSTRUCTION
PROJECT: LOFTIKA
PROJECT NO.: E-0617
FILE NO: E-0617 BA; 1
COMPUTED BY: E.N. DATE:
CHECKED BY: O.S. DATE:
05/08/06
0
DRAINAGE CALCULATIONS FOR WATER QUALITY
"C" Factor for Impervious Areas
"C" Factor for Pervious Areas
Acres of Impervious Areas
Acres of Pervious Areas
Length (LF) of French Drain provided
Seepage Capacity in CFS/LF
Available Storage per LF
Weighted Coefficient of Runoff
Total Drainage area in acres (AC)
Volume of 1.93 Inch of Runoff in CF
Storm Frequency in years
Initial Time of Concentration in MIN.
Time to Generate 1.93 Inch of Runoff
Time to Generate & Flow 1.93 Inch of Runoff
0.90 [CONST]
0.3 [CONST]
1.08 [ACRES]
0.34 [ACRES]
25 [FEET]
0.00652 [CFS/L.F OF TRENCH]
15.08 CU.FT./L.F.
0.76 [CONST]
1.42 [ACRES]
9,941 [CU.FT.]
5 [YEARS]
[MIN.]
38 [MIN.]
43 [MIN.]
5
Note : 1.93 inch of runoff = 2.5 times the percentage of area impervious
ray
BROWARD
Project Site
w
J
N
z
0
U_
W'
O
0
Z '_
J •
H
3`:
fvi
0
z -
EVERGLADES
NATIONAL
PARK
COUNTY
METROPOLITAN
DADE COUNTY
PUBLIC WORKS
DEPARTMENT
.. r r Rovto
6 /24:77
REVISED
GENERAL DETAIL
BASE MAP
OF DADE COUNTY
-
JUSE WITH OVERLAYS 18t 2)
_. .tea-
7.3
SHEET .LOF I
A►�
d�-
SLY
SRS Engineering, Inc.
14160 Palmetto Frontage Road, Suite 22
Miami Lakes, Florida 33016
Tel: (305) 817-3393
Fax: (305) 817-3394
LOFTIKA
Location Map
/1- BROW-ARD
T
er /
f
�
I '
/ /
(SJ
fe
COUNTY 117 S7/ —
RANGES EAST G115• •, •f
�f.I •C •C(•I
/ G•4ae
/ r
6
5, 4
54
44.
Project Site
Oct. Ground Water
Elev. = 3.0
502
G 25,
G 565 •
;6
• •
SCALE IN MILES
5 6 i
y
Lr
• 6 970
•Y
•
0
:Jr
s" - NOTES
I- CONTOUR INTERVAL 1.0 FOOT
(Except as indicated)
�° ' •� 2. DATUM IS MEAN SEA LEVEL.
o
�
•
•
• t •
LEGEND:
__2_--
(ESTIMATED)
NOTE' PREPARED FROM USGS.
SURVEY DATA
METROPOLITAN
DADE COUNTY
PUBLIC WORKS
DEPARTMENT
A.FFROVEC
4/. 72
REVISED
2f"a. 1S
4/1w/'77
DESIGN STANDARDS
AVERAGE OCTOBER
GROUND WATER LEVEL
1960 —75
W.C.
2-.2
S EET I OF
SRS Engineering, Inc.
14160 Palmetto Frontage Road, Suite 22
Miami Lakes, Florida 33016
Tel: (305) 817-3393
Fax: (305) 817-3394
LOFTIKA
Average October Ground Water Level
I
S c e 10 15 20 30 60
IOO YR.FREQ. ^� MAXIMUM RAINFALL RECORDED AT MIAMI 1
- INCHES
0 YR_FREp. 9 i TIME AMOUNT pER HR. DATE
25 YR. FR p. ■��I, I 5 MIN. .83 .96 (7/13/57)
IS I.B9 7.56 (10/II/47)
-p Y. FR ' III\�. 30 3.02 6.04 (9/3/59) - -
B';��I'l11'1i Illy.
�111' ', ,,(` 60 1HR. 4.60 4.60' (4/25/79)
5 YH.FREO. 'j ����11' �"It ��11 2 HRS. (4/25/79)
®•',�11�1'�'�_ ii.i '�\I� 3 (4/25/79)
3�IR FRE•. ��1\r- i
�,1 1 I\, \1 \ (4/24,25/79)
1 YR. FREp. 6',I !I��� ,1``I� I''��� 1� , 1 z
�i .11•
30/25)-. ..
Ititili01100,4M6
' , 17.26 (5/31,6/IZ/30)
19 28� - (5/29,6/2/30)
' �1i • 31.8 I (5/27, 6/25/0)' iils1k1i11►►1 24
IIIIIIiiiI;ibioIIIIIiffluI
lkilippNook
-i'l$kl'Illl'‘I'k
#1111
175 1111-00S
o m Z
0 o J 1.5 11 '`I ,1 ��,��
C � J
q11
I I
- -
i I
'Ik'\
1
mAo 1,it�,Iii►►►►.
0.7,ll11"'lll®i®'1®,lll"' , 1U(thi1ilt-
11 Ili 1 IM1 Y `kI Y..
10 15 20 30 40 60 2 - 3 - 4 - 5 6 - T 8 -/O /2
lc = MINUTES HOURS
NOTES
CURVES REVISED TO 1/74, TABLE REVISED TO 3/81
SOURCE:
OAVtD__YARNELL,. D..B.S.MIT.H,.R...K. LINSLEY, G. E. McCURDY, U. S. CORPS OF ENGINEERS
U.S. WEATHER BUREAU, A. G. MATHEWS (FLA. CONS. DEPT.), AND OTHERS.
Wir
SRS Engineering, Inc.
14160 Palmetto Frontage Road, Suite 22
Miami Lakes, Florida 33016
Tel: (305) 817-3393
Fax: (305) 817-3394
LOFTIKA
Rainfall Intensities - Miami
rs 20 = rr rs
LEAN
• V U
GARDENS
• ))
C.N.
. MEOL Y -
7 r•..uc. • • ! • r
N/A /
IIPRI • SSl
30
), .3
Project Site
Elev. 5.5
r ra
JD/NNER KO'
»n.n
\]— 5.5
RTH NIAp/
30
Y/ SNORES
53 -42;
F/SNER
SIANO.
.11
N,RD
))
5NRF5/O
SRS Engineering, Inc.
14160 Palmetto Frontage Road, Suite 22
Miami Lakes, Florida 33016
Tel: (305) 817-3393
Fax: (305) 817-3394
LOFTI KA
Miami -Dade Flood Criteria Map
Attachment C
Existing Utility Records
6IZS
SRS Engineering, Inc.
284
18":
1211
125
s
1281
- r
4887\
Project Site
SEWER (J-13)
28
144
177
/112
11J •
4087
28
6B6
505
26
VW
SRS Engineering, Inc.
14160 Palmetto Frontage Road, Suite 22
Miami Lakes, Florida 33016
Tel: (305) 817-3393
Fax: (305) 817-3394
LOFTIKA
MDWASD SEWER ATLAS SHEET
a
CO
0
270
7408 1
�70 f
12"
4•"
( 7408
4n
3
a
(sty)
VJESTER
nit,. S
l7270
NN
12"
7408
8)
7186
Project Site
WATER (J-13)
NWST
U
(2237 '\I
i
7186
r
7853
NW 5 ST
SRS Engineering, Inc.
14160 Palmetto Frontage Road, Suite 22
Miami Lakes, Florida 33016
Tel: (305) 817-3393
Fax: (305) 817-3394
LOFTIKA
MDWASD WATER ATLAS SHEET
Attachment D
Pump Station Monthly Information
6.11S
SRS Engineering, Inc.
APR. 20.2006 2:58PM Pump Station Monthly InformatLon
Station..30 -0117 .Atlas pg..1713
MIAMX DADE WATER & SEWER DEPARTMENT
Addr..1090 NW 33 CT
Sec -Town .p-Range 33-53-41
Ge r.0 ET clock.1 Te1m.Y #Pumps. 2
Pump Type.B Stn Ciass.L Speed.2 nr'spwr.a.
Res flow(gpd) Proj Napot % Cap
PZan.. 35,979 6.76 hrs 68.00
Date
02/13/2006
01/12/2006
12/09/2005
11/08/2005
10/10/2005
09/09/2005
08/10/2005
Mo . NAPOT Avg Daily
5.69
5.79
5.76
5.84
7.77
6.11
5.69
5.79
5.76
5.84
7.77
6.11
.92 5.92
Regard
Reading
Y
Y
Y
Signature..VEtA E
4.D/M Station i<m provement GOLD/S
GMD/D <D>ournstream Station
LD/G Codes & Cata<g>aries COLD/'.P
Na 360 {P.: man Review.>
Moratorium —OK
. 4,4
Moratorium effective since
Yearly NAPOT (hrs )
Stn Gross Uapacity(gpd) .
Station Reduction ?actor
Stn Net Cap Certi f (gpd) , .
Str2 Net. Capacity (gpd) ... .
Indicated Flaws(gpd)
6.56
4,896,000
1.00
0
4,096,100
1,342,320
Number
of pumps
2
2
2
2
2
Sign Date..03/03/1995 14:18:2D.f4
cS>tation Inform. GOLD/U <U>pstream Station
GOLD/P <P>'oxnp Information
Sewor Cer<t>ification
Continents
11)-, 41"-C)0-.3
Cfr( 2,0 TOG
A►�
SRS Engineering, Inc.
14160 Palmetto Frontage Road, Suite 22
Miami Lakes, Florida 33016
Tel: (305) 817-3393
Fax: (305) 817-3394
LOFTIKA
SEWER PUMP STATION
INFORMATION