HomeMy WebLinkAboutConcurrency ReportProposal No 06-18
Date: 5/24/06
CONCURRENCY MANAGEMENT ANALYSIS
CITY OF MIAMI PLANNING DEPARTMENT
IMPACT OF PROPOSED AMENDMENT TO LAND USE MAP
WITHIN A TRANSPORTATION CORRIDOR
AMENDMENT INFORMATION
CONCURRENCY ANALYSIS
Applicant: Simon Ferro, Esq. on behalf of A+ Mini Storage Airport East, LLC
Address: 1851 Delaware Parkway
Boundary Streets: North: n/a East: n/a
South: n/a West: Delaware Parkway
Proposed Change: From: Single Family Residential
To: General Commercial
Existing Designation, Maximum Land Use Intensity
Residential 0.009 acres @ 9 DU/acre 0 DU's
Peak Hour Person -Trip Generation, Residential 0
Other sq.ft. @ FAR 0 sq.ft.
Peak Hour Person -Trip Generation, Other
Proposed Designation, Maximum Land Use Intensity
Residential 0.009 acres @ 150 DU/acre 1 DU's
Peak Hour Person -Trip Generation, Residential 1
Other sq.ft. @ FAR 0 sq.ft.
Peak Hour Person -Trip Generation, Other 0
Net Increment With Proposed Change:
Population 3
Dwelling Units 1
Peak Hour Person -Trips 1
Planning District Allapattah
County Wastewater Collection Zone 315
Drainage Subcatchment Basin J1
Solid Waste Collection Route 25
Transportation Corridor Name NW 20th Street
RECREATION AND OPEN SPACE
Population Increment, Residents 3
Space Requirement, acres 0.00
Excess Capacity Before Change 182.80
Excess Capacity After Change 182.80
Concurrency Checkoff OK
POTABLE WATER TRANSMISSION
Population Increment, Residents 3
Transmission Requirement, gpd 731
Excess Capacity Before Change >2% above demand
Excess Capacity After Change >2% above demand
Concurrency Checkoff OK
SANITARY SEWER TRANSMISSION
Population Increment, Residents 3
Transmission Requirement, gpd 603
Excess Capacity Before Change See Note 1.
Excess Capacity After Change See Note 1.
Concurrency Checkoff WASA Permit Required
STORM SEWER CAPACITY
Exfiltration System Before Change On -site
Exfiltration System After Change On -site
Concurrency Checkoff OK
SOLID WASTE COLLECTION
Population Increment, Residents 3
Solid Waste Generation, tons/year 4
Excess Capacity Before Change 800
Excess Capacity After Change 796
Concurrency Checkoff OK
RELEVANT MCNP GOALS, OBJECTIVES, AND POLICIES
Land Use Policy 1.1.1
CIE Policy 1.2.3
TRAFFIC CIRCULATION
Population Increment, Residents 3
Peak -Hour Person -Trip Generation 1
LOS Before Change B
LOS After Change B
Concurrency Checkoff OK
NOTES
1. Permit for sanitary sewer connection must be issued by
Metro -Dade Water and Sewer Authority Department (WASH),
Excess capacity, if an , is currentlynot known
Y
CM 1 IN mil van
ASSUMPTIONS AND COMMENTS
Population increment is assumed to be all new residents. Peak -period trip
generation is based on ITE Trip Generation, 5th Edition at 1.4 ppv average
occupancy for private passenger vehicles. Transportation Corridor capacities and
LOS are from Table PT-2(R1), Transportation Corridors report.
Potable water and wastewater transmission capacities are in accordance with
Metro -Dade County stated capacities and are assumed correct. Service
connections to water and sewer mains are assumed to be of adequate size; if not,
new connections are to be installed at owner's expense.
Recreation/Open Space acreage requirements are assumed with proposed
change made.