HomeMy WebLinkAboutNotice of Acceptance 2Overhead Door Corporation. ACCEPTANCE NO: 01-0529.06
APPROVED: AUG 2 3 2Qal
EXPIRES: AUG2 3 2006
NOTICE OF ACCEPTANCE: SPECIFIC CONDITIONS
1.0 SCOPE
1.1This approves a roll up door with maximum dimensions of as described in section 2 of this Notice of
Acceptance. It is designed to comply with the South Florida Building Code, 1994 edition for Miami -Dade
County (S.F.B.C.). For the locations where the pressure requirements, as determined by the S.F.B.C. chapter 23,
do not exceed the design pressure rating values indicated on the approved drawings.
2.0 PRODUCT DESCRIPTION:
2.1 The Overhead Steel Rolling Door and its components shall be built in strict compliance with the following
documents: Drawing No. D-308028, sheets 1 through 4 of 4, titled "Series 610/620 Rolling Service Door Dade
County", prepared by Overhead Door Corporation, with no dated and last revision on 07/25/01. The drawing
shall bear the Miami -Dade County Product Control approval stamp with the Notice of Acceptance number and
approval date by the Miami Dade Product Control Division. These documents shall hereinafter be referred to as
the approved drawings.
3.0 LIMITATION:
3.1 Units with dimensions equal to or smaller than those shown on the approved drawing shall qualify under this
Notice of Acceptance, as long as all components are exactly as described in this approval.
4.0 INSTALLATION:
4.1 The Roll -Up Door and its components shall be installed in strict compliance with the approved drawings.
4.2 The installation of this door does not require a hurricane protection system.
4.3.The door operating mechanism. (not included on this approval) shall be certified by Underwriters
Laboratories or other recognized agency.
5.0 LABELLING
5.1 Each door shall bear a permanent label with the manufacturer's name or logo, city, state and the following
statement "Miami Dade County Product Control Approved"
6.0 BUILDING PERMIT REQUIREMENTS.
6.1 Application for Building Permit shall be accompanied by copies atilt following:
6.1.1 This Notice of Acceptance including duplicate copies of the approved drawings, identified in section 2;
clearly marked to show the components selected for the proposed installation.
6.1.2 Any other document required by the Building Official or the S.F.B.C. in order to properly evaluate the
installation of this system.
Candido Font, PE, Sr. Product Control Examiner
Product Control Division
-2-
Overhead Door Corporation. ACCEPTANCE NO : 01-0529.06
APPROVED:.AUG 2 3 2001
EXPIRES : AUG 2 3 79°6
NOTICE OF ACCEPTANCE STANDARD CONDITIONS
1. Renewal of this Acceptance (approval) shall be considered after a renewal application has been filed and the
original submitted documents, including test -supporting data, engineering documents, are no older than eight (8)
years.
2. Any and all approved products shall be permanently labeled with the manufacturer's name, city, state and the
following statement: "Miami -Dade County Product Control Approved", or as specifically stated in the specific
conditions of this Acceptance.
3. Renewals of Acceptance will not be considered if:
a) There has been a change in the South Florida Building Code affecting the evaluation of this product and the
product is not in compliance with the code changes;
b) The product is no longer the same product (identical) as the one originally approved;
c) If the Acceptance holder has not complied with all the requirements of this acceptance, including the correct
installation of the product;
d) The engineer, who originally prepared, signed and sealed the required documentation initially submitted, is
no longer practicing the engineering professions.
4. Any revision or change in the materials, use, and/or manufacture of the product or process shall automatically be
cause for termination of this Acceptance, unless prior written approval has been requested (through the filing of
a revision application with appropriate fee) and granted by this office.
5. Any of the following shall also be grounds for removal of this Acceptance:
a) Unsatisfactory performance of this product or process;
b) Misuse of this Acceptance as an endorsement of any product, for sales, advertising or any other
purpose.
6. The Notice of Acceptance number preceded by the words Miami -Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the Notice of Acceptance is
displayed, then it shall be done in its entirety.
7. A copy of this Acceptance as well as approved drawings and other documents, where it applies, shall be
provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at
all times. The engineer need not reseal the copies.
8. Failure to comply with any section of this Acceptance shall be cause for termination and removal of Acceptance.
9. This Acceptance contains pages 1, 2, and this last page 3.
Candido Font, PE, Sr. Product Control Examiner
Product Control Division
END OF THIS ACCEPTANCE
-3-
Overhead Door Corporation. ACCEPTANCE NO: 01-0529.06
APPROVED: AUG 2 3 2001
EXPIRES: AUG 2 3 2006
NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED
A DRAWING:
1. Drawing No. D-308028, titled "Series 610/620 Rolling Service Door. Dade County", sheet 1 through 4
of 4, prepared by Overhead Door Corporation, without date but revised for last time on 07/25/01,
signed and sealed by L. G. Krupke, PE.
B TEST:
1. Test report on. Uniform Static Air Pressure per PA 202,Large Missile Impact Test per PA 201 and
Cyclic Wind Pressure Test per PA 203 of "Steel Roll Up Service Door" prepared by Architectural
Testing, Inc., report No. 01-38195.01, dated 05/08/01, signed and sealed by A. N. Reeves, PE.
C CALCULATIONS:
1. Calculations prepared by Overhead Door Corporation, sheets 4 of 4 of drawing D-308028, signed and
sealed by L. G. Krupke, PE. on 07/25/01.
D STATEMENTS:
1. Code Compliance and No Financial interest letter issued by Overhead Door Corporation, on 07/24/01,
signed and sealed by L. G. Krupke, PE.
2. Test Compliance letter issued by Architectural Testing, Inc., on 05/09/01, signed and sealed by A. N.
Reeves, PE.
E MATERIAL CERTIFICATION:
I. Test Report on Tensile Test per ASTM E-8, of "Coupons from PA201, PA202 and PA203 tests",
prepared by Architectural Testing, Inc., dated 05/08/01, signed and sealed by A. N. Reeves, PE.
Candido Font, PE, Sr. Product Control Examiner
Product Control Division
-El-