Loading...
HomeMy WebLinkAboutTab D - Site Utility StudyD. SITE UTILITY STUDY MIADOCS 838506 1 October 2005 5220 BISCAYNE BOULEVA MAJOR USE SPECIAL PE IT SITE UTILITY STUDY PREPARED FOR Societe de Prise de Partkpation Financiere, Inc. KHA Project No.: 042272004 Prepared by: KIMLEY-HORN AND ASSOCIATES, INC. 1691 Michigan Ave, Suite 400 )MIAMI BEAM FL 33139 vm 11,1 1111 11111111 Kimley-Horn and Associates, 111111111111111111111... 111111111111111111111111111111111111yilil1111111111111syyyyyyyypIl „HI 111111111111 IIIIIIIIIIIIIIIII111111111111111111111111111111111111111111111111111111111IIIIIIIIIIIIII111111111111111111111111))),m11111111111 11111111111111111111111111 11111111111111111111111111111 11111111111111111111111111111111111111„„„„„,n11 '11111111111111111111111 IIIIIIIII111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111 IIIII111111111111111111111111111111111111111111111111,11111111111111111111111111111111111111111 IIH-111111111III11111111111111111,„„„„„„„„„„„„, I"Iml I 11111111111111111111111111"H' 11111111111111111111111111111111111111111111110,11110101010101010101010101010101010101010101 1111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111 11111111111111111""" „„„„„„„„„„„ 111111111111111111111111111111111111! 111111111 1111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111 NIINIIIIIIII'll'1111111111111111111111111111111111111111111111111111111111111111iffn,h,ffffffffffffffffffffffffffffffffffn,1;11:1;;'11111111111111111111111111111i •'• ••• 1111111111111, 1111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111 111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111 11111111111111111111111111111111 1111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111 1111111111., „„„ 1111111111111111 mmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmm 1111111111 11111111 IIIIIIIIIIIiI111111111111 11111111111111111111111111111111111111111111111111111111111111111mhifihm111111111111111111111111111111111111111011 11111111111111111111111111111111111 m 111111111111111111111101111111111111111111111111,11,1 1111111111 h111111111111111111111 111111 111111 111111111 1111 1111 11 1111111111111111111 MMMMM111111111111111111111111111111 IIIIIIIIIIIIIIIIIIIIII11111111111111111111111111111 111111111111111111 1111111 1111111 1111111 11111111111111 111111111111111111111111111111111111111111111111111IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII 1111111111111111111111111111111 11111111111111111111111 1110m111111111, 1111111 Im1111111111111111111 111111111111111111111111111111111111111111111111111111111111111111111IIIIIIIIIIIIIIIII1111111111111111111111111111111111111111111111111111111111111111111111111111i 11111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111 1111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111 IIIIIIImmmmmm11111111111 ..............""""" ............, 1111111111111111111111111111111.1111111111111111111111111111111111111111111111111111111111iiiiiiiiiiiiiiiiiqhliiiiiiiiiithihyiiiiiiiiimiiiiimimylylylyhi 111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111. Site Utility Study Introduction 5220 Biscayne Boulevard is a proposed mixed -use development to be located on 1.85 +1- acres in the City of Miami, Miami -Dade County, Florida. It is located between NE 52nd Terrace and NE 52nd Street, along N. Federal Highway on the West and Biscayne Blvd on the East. (See Attachment "A" Maps). Currently, the site is occupied by a three story residential tower and an asphalt parking lot. All existing on -site facilities will be demolished as a part of this project. The proposed 5220 Biscayne Boulevard project will include an 11 story residential tower and a parking garage to serve the tower. A total of 177 residential apartment units, 10,500 S.F. of commercial space and approximately 312 parking spaces will be constructed for this development. A tabular breakdown of the project details is depicted in Table 1- "Project Summary" below. Table 1: Project Summary Occupancy Units F1 or Area (sf) Residential 177 164,705 Commercial - 10,500 Parking 312 spaces - Total - 175,205 5220 Biscayne Boulevard Site Utility Study Page 1 I. Drainage Relative to the aforementioned project, the following information shall be used during the storm water management design and site grading. Flood Criteria: The proposed project site grade elevations will be designed to meet flood criteria according to Federal State, Miami -Dade County and City of Miami standards as follows: 1. The subject property is located in PANEL 181 of COMMUNITY -PANEL NUMBER 12025C0181 J of the Flood Insurance Rate Map (FIRM). According to the National Flood Insurance Program, the project is in Zone X. As such the project area has been determined to be outside 500 years floodplain. 2. Miami -Dade County Flood Criteria elevation is estimated to be 5.0 ft. NGVD. This will be used to determine proposed minimum grade elevations. 3. The average October ground water table elevation is estimated to be 2.0 ft. NGVD. This elevation will be used to compute drainage well capacity and roadway base clearance. (Source: Dade County Department of Environmental Resource Management & Miami -Dade County Public Works Manual, Volume II - Design Standard Detail WC 2-2). Existing Drainage Based on site observations and other available information, there is a drainage system currently serving the existing building and asphalt parking lot. This existing drainage system will be demolished and a new stormwater management system will be constructed to retain the runoff generated by the proposed improvements, as required by code (see "Proposed Drainage System" below). 5220 Biscayne Boulevard Site Utility Study Proposed Drainage System The drainage system for the proposed development will consist of a combination of drainage wells and exfiltration trench, to facilitate on -site disposal of storm water runoff. , In accordance with Section D-4, "Water Control", of Part 2 of the Miami -Dade County Public Works Manual, the 5-year 24-hour design storm event will be used to design the new storm water management system. Based on preliminary calculations, it is anticipated that three (3) 24" drainage wells will provide sufficient capacity to dispose of the storm water runoff generated by the proposed development. Preliminary drainage computations for the project areas are provided in Attachment B "Preliminary Drainage Well Calculations", which includes the basis for design. The final drainage design for the project should be in conformance with the requirements of the Miami -Dade County DERM Water Control Section, Florida Department of Environmental Protection, and other local, state and federal regulatory agencies having jurisdiction over the project. II. Water Distribution System The water mains owned and operated by the Miami -Dade Water and Sewer Department (MDWASD) in the vicinity of the project are shown in the Table 2. 5220 Biscayne Boulevard Site Utility Study Page 3 Table 2: Existing Water Mains (Per MDWASD Water Atlas Sheet) Location Between Water Main(s) Biscayne Boulevard N.E. 53rd Street and N.E. 52nd Street 8" Federal Highway N.E. 53rd Street and N.E. 52nd Street 8" and 12" Per MDWASD Water Atlas, an existing 8-inch water main fronts the property along Federal Highway. A 12-inch water main extends along a small portion of the site on Federal Highway. There is also an 8-inch water main within the right-of-way of Biscayne Boulevard. In accordance with Miami -Dade Water and Sewer Department (MDWASD) criteria, the developer may be required to extend the existing 12-inch water main southerly along Federal Highway, so that it fronts the entire length of the Western boundaries of the property. A final determination of this and the required points of connection will not be provided by MDWASD until a Water and Sewer Agreement is requested by the owner and/or the Hydraulic Analysis undertaken by MDWASD is completed. Water service meters will be installed by MDWASD forces at owner's expense. A copy of the MDWASD water atlas sheet for the project area has been included in Attachment "C" for a III. Sanitary Sewer Collection System Table 3 depicts the sanitary sewer mains owned and operated by Miami -Dade Water and Sewer Department (MDWASD), within the vicinity of the project. 5220 Biscayne Boulevard Site Utility Study Page 4 Table 3: Existing Sanitary Sewer Mains (Per MDWASD Sewer Atlas Sheet) Location Between Sanitary Sewer Main(s) Federal Hi Highway g y N.E. 53rd Street and N.E. 52nd Street 36" Force Main 4$" & 8" Gravity line The proposed on -site sanitary sewer system for the property may be connected to either of the existing mains along Federal Highway; provided that the line has sufficient capacity to handle the additional flows contributed by the proposed project. MDWASD may also require upgrades to the sanitary sewer system. However, final determinations on these issues cannot be made until the necessary coordination has been completed with MDWASD. A letter of availability is recommended to verify the proposed sanitary sewer service connection points and requirements for this project. As is the case with the water service connections, public improvement requirements for sanitary sewer services will not be provided by MDWASD until a Water and Sewer Agreement is requested by the owner. The flows from sanitary sewer mains are received by MDWASD Regional Pump Station #2, which is located at 925 Biscayne Boulevard. Pump Station No. 2 is currently operating at an average yearly NAPOT of 2.89 hours/day, and is presently not under any type of moratorium (see attached pump station report). It is not anticipated that any improvements to the regional pumping and/or transmission systems will be required to connect the proposed project. However, a final determination regarding the status of the existing transmission system and the need for possible improvements will not be made until construction plans are submitted to the Miami -Dade County DERM Wastewater Section and a Sanitary Sewage System Capacity Certification Letter is issued. 5220 Biscayne Boulevard Site Utility Study Page 5 The additional flows created by this project have been determined and are shown in Table 4 below. Table 4: Water & Sewer Flow Generation IV. Solid Waste Generation Solid waste generated by this project will be collected in standard on -site containers for refuse and recyclables. Regular pick-up services will be provided either by private hauling companies and/or by the City of Miami Solid Waste Department, who will transport the waste to Miami -Dade County's or private disposal and recycling facilities. The volumes of solid waste projected to be generated by the project are shown in Table 5. Table 5: Solid Waste Generation Type of Occupancy Phase I Quantity Usage Rate Total Solid Waste Generated (Tons/Day) Apartment 177 units 5lbs/unit/day 0.44 Retail r 10,500 sf 6lbs/1000 sf/day 0.03 Total Anticipated Solid Waste Generated 0.47 5220 Biscayne Boulevard Site Utility Study Page 6 Attachment A Maps 5220 Biscayne Boulevard Site Utility Study A BROWARO 01,04 C104 ' C<C0.06, *4� z yt, . -- 044 IISS I +.—it,. • U 2...... — (ESTIMATED) NOTES i. CONTOUR INTERVAL 1.0 FOOT. (Except at in4ica ed) 2. t14T1JM is MEAN SEA LEVEL vim Kimley-Horn and Associates, } 1111e 1691 Michigan Ave Suite 400 Miami Beach, Florida 33139 Phone: 305-673-2025 Fax: 305-673--4882 5220 BISCAYNE BOULEVARD AVERAGE OCTOBER GROUND WATER LEVEL 1960-75 Kimley-Horn and Associates, Inc. 1691 Michigan Avenue Suite 400 Miami Beach, Florida 33139 Phone: 305-673-2025 Fax: 305-673-4882 5220 BICAYNE BOULEVARD CITY OF MIAMI, FLORIDA FLOOD CRITERIA MAP NE 59TH ST N z E 58TH TE 58TH ST NE 57TH ST Q w z Q NE 56TH ST 0 NE 55TH TE 0 z NE 55TH ST ST \ E 5 4TH ST 4 TH ST zi NE 56TH ST NE 55TH TE w z. NE 50TH TE LAKE RD BUTTONWOOD LA Kimley-Horn and Associates, Inc. 1691 Michigan Avenue Suite 400 Miami Beach, Florida 33139 Phone: 305-673-2025 Fax: 305-673-4882 5220 BISCAYNE BOULEVARD FLOOD CRITERIA MAP 4NTI- APPROXIMATE SCALE 500 0 500 FEET NATIONAL FLOOD INSURANCE PROGRAM FIRM FLOOD INSURANCE RATE MAP DADE COUNTY, FLORIDA AND INCORPORATED AREAS PANEL IBI OE 625 1: {SEE unv wDE.1, FOR PANELS NOT r'641.4TED) CONTAINS: io COIMPITY taBEA PANEL SIAfiII rre.=m. •a svii• �I Yrkja.=•'?' Ci 3} MAP NUMBER 12025C0181 ,1 MAP 13EISED MARCH 2, 1994 �;;!j Fellers] Fmergenct Mnnegrwrnf Agency This is an oficial copy of a portion of the above referenced flood map. It was extracted using F-MIT On -Line. This map does not reflect changes or amendments which may have been made subaoquent to the dale on the title dock. Far the Latest product information about National Flood Insurance Program flood maps check the FEW Flood Map Store et www.mSC.fema.gov Attachment B Preliminary Drainage Well Calculations 5220 Biscayne Boulevard Site Utility Study 5220 BISCAYNE BOULEVARD City of Miami, Florida DRAINAGE CALCULATIONS: DRAINAGE WELLS (MASS DIAGRAM — DERM CRITERIA) 1. Site Data: A. Average October Water Table Elevation B. County Flood Criteria Elevation = C. F.I.R.M. or FEMA Base Flood Elevation = D. Average Crown Road Elevation E. Average Existing Onsite Grade Elevation = F. Proposed drainage inlet grate elevation = 2.00 NGVD 5.00 NGVD (County Flood Criteria Map, see Appendix A) WA Zone X (Map No. 12025C0181 J, see Appendix A) 12.85 NGVD 1260 NGVD 1250 NGVD 2. Total Contributing Drainage Area (A): 2.16 Acres A. Impervious Areas: a) Asphalt and concrete pavement = b) Roof areas + 1/3 NE building corner = 0.80 Acres 1.31 Acres Total Impervious Area (Al) = 2.11 Acres (98%) B. Pervious areas: a) Green Areas = 005'; Acres (2%) 3. Weighted Runoff Coefficient (C): Runoff Coefficient Impervious (C1) Runoff Coefficient Pervious (C2) _ C= [(Al xC1)+(A2xC2)]IA; C= C x A = Total Contributing Area; C x A= 0.90. 0.30 0.89 1.91 Acres 4. Time required to generate one inch of runoff (per DERM Water Control Section D-4) Rainfall Intensity (I) = 308.5 / [(48.6 x F4111) + t (0.5895 + F73)] Frequency (F) = years - Frequency Curve Q = CIA, V = Qt; V() in.} = Qt(1 in.). t(1 in.) = Time to generate 1 inch of runoff V(1 in.) = CIAt(1 in.) 1" x A = CIAt(1 in.) Salving for t(, in.), t{1 in.) = 1" / (IC) Time to Generate one inch of run-off t(in) = 11.24 Min. Time to reach the inlet (tc.) = 10.00 Min. Total Time required to generate 1 in of runoff: — 21.24 Min. VISTA BiSCAYNE DRAINAGE WELLS_ A1tschmenl B.xls BASIN 5. Cumulative Runoff (Inflow Mass Diagram) Time CXA (acres) 1 (inches) Q (CFS) Accumulated Storm .Runoff (CF) (IMin.) (Sec.) 8 480 1.915 6.405 12.26 5,886 10 600 1.915 6.166 11.81 7,084 15 900 1.915 5.641 10.80 9,721 21.24 1274 1.915 5.099 9.76 12,443 30 1800 1.915 4.493 8.60 15,485 40 2400 1.915 3.956 7.57 18,180 50 3000 1.915 3.534. 6.77 20,300 60 3600 1.915 3.193 6.11 22,011 90 5400 I.915 2.477 4.74 25,609 120 7200 1.915 2.023 3.87 27,888 180 10800 1.915 1.480 2.83 30,612 6. Drainage Well Design Discharge Rate: Based on well discharge rate of: 400 GPM/ft. Head Well No. Lowest Inlet Rim Elev. (NGVD) Oct. Water Table elev. (NGVD) :: Headloss due to Higher SG of Salt Water (ft.) : Head Acting on Well (ft.):; Well Discharge Rate (CFS) Well Structure Dimensions Well Structure Storage Volume (CF) Width (ft) Length (ft.) DW-1 12.50 2.00 2.20 8.30 7.40 7.0 12" ;: 697.2 DW-2 12.50 2.00 s 2.20 8.30 7.40 '. 7.0 12.0 697.2 DW-3 12.50 2.00 2.20 8.30 7.40 7.0 12,0 697.2 Well Discharge Rate (CFS) 7. Detention Time: 22.19 Total Storage (CF) The drainage well structure must be designed to detain runoff for a minimum of 90 seconds prior to discharge. Qd = Design Runoff Rate (CFS) Vd = Detention Volume (CF) = Qd x 90 sec. Val = Detention Volume Per Weil (CF) = W = Width of Well Structure (ft.) = L = Length of Well Structure (ft.) = 9.76 CFS 878.65 CF 292.88 CF 7.0 ft. 12.0 ft. 2091.60 H,,,;„ is the minimum depth required from the top of well casing to the floor of the well box to achieve 90 second detention time: Hmin. (ft.) = Vdi / (W x L) = 3.50 ft. Top of Well Casing Elev. = 10.50 Elevation at Floor of Well Box (NOVD) = Top of Well Casing Elev. - Hm;n. = 7.00 8. Excess storm water runoff excluding well structure storage: Time Well Discharge Rate (CTS) Accumulated Well Discharge Volume (CF) Accumulated Storm Runoff (CF) Total Overflow Volume (CF) (Min.) (Sec.) 8 480 22.19 10,652 5,886 -4,766 10 600 22.19 13,316 7,084 -6,232 15 900 22.19 19,973 9,721 -10,253 21.24 1,274.49 22.19 28,284 12,443 -15,842 30 1800 22.19 39,947 15,485 -24,462 40 2400 22.19 53,262 18,180 -35,082 50 3000 22.19 66,578 20,300 -46,278 60 3600 22.19 79,893 22,011 -57,882 90 5400 22.19 119,840 25,609 -94,231 120 7200 22.19 159,786 27,888 -131,898 180 10800 22.19 239,679 30,612 -209,067 9. Excess storm water runoff including well structure storage: Time S Accumulated : Storm Runoff: (CF) Storage in Well Structure (CF) Accumulated Well Discharge Volume (CF') Total Overflow Volume (CF) (fin.) : (Sec.): 8 480 5,886 2,092 10,652 -6,857.88 10 600 7,084 2,092 13,316 -8,323.44 15 900 9,721 2,092 19,973 -12,344.29 21.24 1,274.49 12,443 2,092 28,284 -17,933.24 30 1800 15,485 2,092 39,947 -26,553.32 40 2400 18,180 2,092 53,262 -37,173.68 50 3000 20,300 2,092 66,578 -48,369.26 60 3600 22,011 2.092 79,893 -59,973.66 90 5400 25,609 2,092 119,840 -96,322.54 120 7200 27,888 2,092 159,786 -133,989.97 180 10800 30,612 2,092 239,679 -211,158.63 Safety Factor Safety Factor 2.27% 2.73% Attachment C Existing Utility Records 5220 Biscayne Boulevard Site Utility Study 1691 Michigan Avenue ❑=❑ Suite 400 Miami, Florida 33143 Kimley-Flom and Associates, Inc. Phone: 305-662,6445 Fax: 305-662.6492 '5220 BISCAYNE BOULEVARD MDWASD SEWER ATLAS SHEET El II Fl Kimley-Hom and Associates, Inc. 1691 Michigan Avenue Suite 400 Micrni, Florida 33143 Phone: 305-662.6445 Fax: 305-662.6492 5220 BISCAYNE BOULEVARD MDWASD WATER ATLAS SHEET E-11 Attachment D Pump Station Monthly Information 5220 Biscayne Boulevard Site Utility Study In ',Alta.P4,thIv Pup 5ta5on.: 30-8012 Alas Poso6 111113 Moffekuitw MV‘1411 DADE WATER 5 EWER DE PARTMENr Seclion-TonvothinTieripr [571.: • gy, • ig ci.s,eFah. Tollow•aby V Fil Nimbi. of Pump.: 5 [YsarlyNAPOT NO: 2.89 Rol llow(gpdk 2.325213 PIA Nepot 4.5 his 45 1484aloonaon of foci so= 11:,,I,,870,1681,! .....F•matriwoomiv ET dock SineroosCapacily(gpel 57,600.4618 Ration Floductice Facto .6 5tnNo4CapCodif[gpte SloNot Capsoky[supd) 34.550.000 lotino1o4Floors(spd) 4.16100 7/28/20105 1215 12.59 ;Y ;5 8800611 :OW*7 527/2805 290 :11.59 Y 5 „.„ 9RODS5 400 " 3/1/21,15,.. ! 292 !11.67 Y '5 • 81509511 Data: Mo.NAPOT Avenel* Fidg Fig I Pimp: Comments: lkfrrn.aV °Am