HomeMy WebLinkAboutArticle II - Project Description•
•
•
SMA
MAJOR USE SPECIAL PERMIT
PROJECT DESCRIPTION
ARTICLE H.
Project Description
A. Zoning Ordinance No. 11000
1. Section 1304.2.1 Application forms; supplementary
materials
2. Section 1702.2.1 General Report
3. Section 1702.2.2 Major Use Special Permit Concept Plan
4. Section 1702.2.3 Development Impact Study
•
•
SMA CONDOMINIUM
MAJOR USE SPECIAL PERMIT
1. Section 1304.1.1 Application forms; supplementary materials
(a) Statements of ownership and control of the proposed development of
activity.
The Disclosure of Ownership and Ownership Affidavit are provided in Article
1.
(b) Statement describing in detail the character and intended use of the
development or activity.
"SMA" will be two residential towers, Tower I: 52 story and Tower II: 56
story with a total of 832 units, 74 office condo, and 1274 parking spaces. The
project is located on South Miami Ave. between Southwest 14th Street &
Southwest 14th Terrace, Miami, Florida. The development consists of a parcel
with a net lot area of 121,259 square feet (2.784 acres). The gross lot area is
164,643 square feet (3.78 acres). The property fronts Southwest 14th Terrace on
the South, Southwest 14th Street on the North, Southwest 1st Avenue on the
West and South Miami Avenue on the East. The zoning designation for the
property is SD-7.
The proposed building will contain 832 residential units, 74 office condos and
1274 parking spaces. The building provides a continuous liner of residential
units along both Southwest 14th Terrace and South Miami Avenue for the entire
12 levels height of the garage. There will be one underground parking level
with 250 parking spaces. The 13th level will contain active amenities such as a
pool, pool bathrooms, planters, gardens and lounge.
The 2 main entrances to the project are off Southwest 1st Avenue for Tower I
and South Miami Avenue for Tower II. The residential entrance to the parking
garage will be off Southwest 14th Terrace, the commercial entrance to the
parking garage will be off Southwest 14th Street and there will be a service
entrance to an internal service court where the required loading spaces are
located off Southwest 1st Avenue. Building residents and guests will be able to
choose between valet parking or self parking.
The ground floor will contain the lobby, service court, office lobby and retail.
The 2nd through 12th floor will contain studios, loft units, office condo, and
parking with some storage designated areas. The ground, second, third and
fourth contain an atrium space that connects to the parking garage. The second,
third and fourth level contain residential amenities to include a gym, spa,
business center and media room. The 13th level will contain (7) residential
units on Tower I and (6) residential units on Tower II, pool, spa, pool deck,
pool bathrooms, planters, gardens, and lounge. The 14th through 52nd levels in
Tower I and 14th through 56th level in Tower II will have all residential units.
•
•
•
The Architects while designing the buildings considered the scale and massing
of the evolving neighborhood placing both towers to maximize viewing
corridors and strategically anchoring both prominent corners of the site.
The Architects provided a plaza fronting South Miami Avenue and a pedestrian
connection through the block in order to break up the scale of this large city
block. The tops of the towers give the project a signature and unique design
for the Brickell Area. The garage which is exposed along Southwest 1s`
Avenue and Southwest 14th Street has been articulated with raised stucco bands
that are painted and scored creating an artistic pattern that enhances the garage
facade. Much consideration was given to the placement of Tower II and the
program facing Southwest 14"' Street due to the existing People Mover so that
the design would comply with the requirements of the Miami Dade Transit
Authority.
(c) General location map, showing relation of the site or activity for which
special permit is sought to major streets, schools, existing utilities,
shopping areas, important physical features in and adjoining the project or
activity and the like.
The following exhibits are included with the Major Use Special Permit
Application:
(1) Aerial: Aerial photograph of the surrounding area indicating the
project site.
(2) Area Context Map/Site Aerial: Map of the project area indicating
buildings and their functions that surround the site including projects
under construction in the area.
(3)
Location Map: Map of the surrounding street system indicating the
project location.
(d) A site plan containing the title of the project and the names of the project
planner and developer, date, and north arrow and, based on an exact
survey of the property drawn to a scale of sufficient size to show:
The general information requested is shown on the Level 1-Ground Floor plan,
provided under Tab 6 of the Supporting Documents. The site plan includes the
following:
(1) Boundaries of the project, any existing streets, buildings,
watercourses, easements and section lines;
The boundaries of the project and the location of existing
streets and easements are shown on the Survey located
under Tab 5 of the Supporting Documents.
(2) Exact location of all buildings and structures;
•
•
•
(3)
The exact location of all existing buildings located on the property is
shown on the Boundary Survey under Tab 5. The location of the
building to be constructed is shown on the Level 1-Ground Floor
Plan, located under Tab 6 of the Supporting Documents.
Access and traffic flow and how vehicular traffic will be
separated from pedestrian and other types of traffic;
Vehicular access for the residential portion of the project is from
Southwest 14th Terrace. Vehicular access for the office condo and
retail portion of the project is from Southwest 14th Street. Access to
the parking garage is located at the lobby. The service drive for the
project, as well as the loading areas are located off of Southwest 1st
Avenue.
A detailed analysis of the site access and traffic flow is provided in
the Traffic Impact Analysis located under Tab 2 of the Supporting
Documents.
(4) Offstreet parking and offstreet loading areas;
(5)
The offstreet parking facility will include 1 underground parking level
as well as 11 parking levels above the ground floor structure with a
total of 1274 parking spaces. The garage is shown on the
underground parking level plan and the Second thru Twelfth floor
parking level plan, provided under Tab 6 of the Supporting
Documents.
The Zoning Ordinance requires five (5) loading bays. There will be
four (4) loading bay 12 ft. x 35 ft. and one (1) loading bay 12 ft. x 55
ft. . The clearance for all loading bays is 15 feet. Service areas are
shown on the Level 1-Ground Floor Plan, under Tab 6 of the
Supporting Documents.
Recreational facilities locations;
The parking roof- level 13th, will serve as a recreation deck for the
development and will include indoor and outdoor amenities. It will
include indoor recreational facilities such as lounge, and pool
bathrooms. Exterior facilities will include a swimming pool with a
pool deck, spa, benches, cabanas, ottomans, gardens and planters.
These facilities are shown on the Level 13-Pool Deck located under
Tab 6 of the Supporting Documents.
(6) Screens and buffers;
Landscaped areas are indicated on the Landscape Plans — Ground
Floor and Landscape Plan — Pool Deck located under Tab 6 of the
Supporting Documents.
•
(e)
•
(f)
(g)
•
(7) Refuse collections areas;
Waste collection will be provided by a containerized compactor
system located within the service area. These facilities are shown on
the Level 1-Ground Floor PIan, located under Tab 6 of the Supporting
Documents.
(8) Access to utilities and points of utilities hookups.
Access and connections to site utilities are discussed in the Site
Utility Study located under Tab 3 of the Supporting Documents.
Tabulations of total gross acreage in the project and the percentages
thereof proposed to be devoted to:
(1) The various permitted uses:
Total Residential and Non -Residential
(SD-7) Sq. Ft. = 121,259 S.F. (Net area)
(2) Ground coverage by structures:
Building Footprint — 91,803 S.F.
Ground coverage by the structures is 75.7% of the total gross lot area.
Tabulation showing the following:
(I)
The derivation of numbers of offstreet parking and offstreet
loading spaces shown in (d) above;
The total number of offstreet parking spaces required is 1,016 spaces and the
total number of spaces provided is 1,274 spaces. Derivation of the number of
offstreet parking is shown under the Project Fact Sheet, within the Project
Summary, located under Tab 6.
(2) Total project density in dwelling units per acre.
As per SD-7 the maximum project density is 500 units per acre. The
designated site is 2.784 acres (net area), which allows for the
construction of 1,392 units. This project will provide 832 units.
If common facilities (such as recreation areas of structures, private streets,
common open space, etc.) are to be provided for the development,
statements as to how such common facilities are to be provided and
permanently maintained.
•
•
•
(h)
(►j
All common facilities to be provided will include the swimming pool, spa, club
room, gym, business center, media room and pool bathrooms. The common
areas will be maintained by the Owner and ultimately by the condominium
associations.
Storm drainage and sanitary sewerage plans.
Storm drainage, water distribution, waste water and solid waste generation
provisions are discussed in the Site Utility Study located under Tab 3 of the
Supporting Documents.
Architectural definitions for buildings in the development; exact number
of dwelling units, sizes, and types, together with typical floor plans of each
type.
Detailed information and breakdown of square footage of all uses are found
under Unit Areas calculations, included under Tab 6 of the Supporting
Documents. Typical floor plans for residential units are shown on the Typical
Residential Floor Plans Level 2-52 on Tower I and Levels 2-56 on Tower IL
All drawings are located under Tab 6 of the Supporting Documents.
(j) Plans for signs, if any.
The project will obtain signage approval at a later date.
(k) Landscaping plan, including types, sizes and locations of vegetation and
decorative shrubbery, and showing provisions for irrigation and future
maintenance.
(1)
(m)
The landscape plans showing vegetation are found on Landscape Plan -Ground
floor, and Landscape Plan — Pool Deck. All landscape plans are located under
Tab 6 of the Supporting Documents.
Plans for recreation facilities, if any, including location and general
description of buildings for such use.
The 13th Level will contain a swimming pool, spa, a recreation deck,
Bathrooms,
The 211d, 3`d and fourth floor will contain the gym, gym bathrooms, business
center, and media room. The recreational facilities for the building are shown
located on the Level 13 - Pool Deck Floor plan and Levels 2, 3, and 4 Floor
plan..
Such additional data, maps, plans, or statements as may be required for
the particular use or activity involved.
•
•
•
(n)
The details of the spaces and calculations used to compute the Floor Area Ratio
(FAR) are shown on the Project Data Sheet, provided under Tab 6 of the
Supporting Documents.
Such additional data as the applicant may believe is pertinent to the proper
consideration of the site and development plan.
Elevations depicting the architectural character of the building on the Buildings
Elevations North, East, and South & West Elevations. All elevations are
located under Tab 6 of the Supporting Documents.
2. Section 1702.2.1 General Report.
(1)
Property ownership and beneficial interest within the boundaries of the
area proposed for Major Use Special Permit.
Statement of Ownership and beneficial interest within the boundaries of the
area proposed for Major Use Special Permit are provided in Article I.
(2) The nature of the unified interest or control.
The nature of unified interest or control is indicated in Article I.
(3) Survey of the proposed area showing property lines and ownership.
A copy of the Surveys is included under Tab 5 of the Supporting Documents.
(4) Map of existing features, including streets, alleys, easements, utilities lines,
existing land use, general topography, and physical features.
The existing site features and utility lines are shown on the Boundary Survey of
the property located under Tab 5. The site features and the utilities are also
described in the Site Utility Study, located under Tab 3 of the Supporting
Documents.
(5)
Materials to demonstrate the relationship of the elements listed in (4)
preceding to surrounding area characteristics.
The drawings submitted with this Application are located under Tab 6 of the
Supporting Documents.
(6) Existing zoning and adopted comprehensive plan designations for the area
on and around the lands proposed for Major Use Special Permit.
The existing zoning designation for the property pursuant to City of Miami
Ordinance No. 11,000, as amended and Plat Book B, at Page 14 of the Public
Records of Miami -Dade County, Florida. (which is located in Article 1),
indicates the existing and surrounding zoning. The zoning designations for the
property are SD-7(Central Brickell Rapid Transit Commercial Residential
District). The Comprehensive Plan Future Land Use designation for the
•
•
•
property is Restricted Commercial. The zoning and the comprehensive plan
designations are consistent with one another.
3. Section 1702.2.2 Major Use Special Permit Concept Plan.
a. Relationships of the concept plan to surrounding existing and proposed
future uses, activities, systems, and facilities (transportation, recreation,
view corridors, pedestrian systems, service systems and similar uses.
Article II contains a written narrative of this project outlining proposed uses,
activities and architectural character. This narrative also contains descriptions
of the project's relationship to traffic, pedestrian movements, and transportation
access. Building elevations, sections and perspectives showing the proposed
materials, vertical profile and height, and orientation to streets are included in
the drawings submitted with this Application. The list of drawings submitted is
found under Tab 6 of the Supporting Documents.
b. Existing zoning and adopted comprehensive plan principles and
designations.
The project conforms with the SD-7 zoning district designation for the
property. The comprehensive plan future land use designation conforms with
the land use designation currently in effect for the property.
4. Section 1702.2.3 Developmental Impact Study.
(a) A traffic analysis shall be submitted for an area within approximately I14
mile of the site, or an area including the major intersections to be impacted
by the site, whichever is larger.
The Traffic Impact Analysis is included under Tab 2 of the Supporting
Documents.
(b)
(0)
Economic impact data shall be provided, including estimates for
construction costs, construction employment, and permanent employment
and shall demonstrate that the proposed development is favorable to the
economy, public services, environment and housing supply of the City.
The Economic Impact Study is included under Tab 4 of the Supporting
Documents.
A housing impact assessment.
Over the last several years prices of urban housing have increased
dramatically; despite the recent slow down in the economy.
Subsequently, a substantial amount of people within metropolitan areas
has begun to return to the city to live. This has created a shortage of
multi -family housing along with an upward surge of housing prices.
Contrarily, the cost of construction has not kept pace with these
increases, which has made it economically affordable to construct new
•
•
•
buildings for sale. This pattern remains the same in South Florida where
there continues to be an increased demand for housing, particularly in
Miami -Dade County.
(d) A description of proposed energy conservation measures shall be provided,
including only those measures that are proposed in addition to the
minimum requirements in State Energy Code.
Architecturally, the building envelope will be comprised of insulated walls and
roof Tinted glass will be used throughout the building. Electrically, all
exterior and landscape lighting will be controlled by means of time clocks and
photocell switches. Energy saving lamps, ballasts and fixtures are being
considered at cores and public spaces.
(e). Historic Buildings
There are no historic structures located on the property.
(1). Environmental Zone
The property is located within an environmental preservation district.