Loading...
HomeMy WebLinkAboutSite Utility StudyFebruary 2005 Vista Biscayne MAJOR USE SPECIAL PERMIT SITE UTILITY STUDY PREPARED FOR Vista Biscayne, L.L.C. KHA Project No.: 042462000 Prepared by: KIMLEY-HORN AND ASSOCIATES, INC. 1691 Michigan Ave. Suite 400 MIAMI BEACH, FL 33139 Vista Biscayne Site Utility Study Page 1 • • Site Utility Study Introduction Vista Biscayne is a proposed residential development to be located at approximately 446- 452 NE 29th Street, on approximately on half acre, in the City of Miami, Miami -Dade County, Florida (see Attachment "A" Site Location Map). Currently, three one story residential units, and two other buildings exist on the site, all of which are to be demolished as part of this project. The Vista Biscayne project includes a 17 story residential tower and a parking garage. The development will consists of a total of 41 residential apartment units, and approximately 60 parking spaces. See Table 1, below for further details of the proposed project. Table 1: Project Summary Residential 41 124,173 Parking 60 spaces Total 124,173 Vista Biscayne Site Utility Study Page 2 • • • I. Drainage Existing Drainage Presently, the site is developed with three one story residential units, and two other buildings with a portion of a concrete patio and a driveway balancing the site. The existing drainage system will be demolished and a new stormwater management system will be constructed to retain the runoff generated by the proposed improvements, as required by code (see below). Proposed Drainage System The drainage system for the proposed development will consist of drainage wells and exfiltration trench, if possible, to facilitate on -site disposal of storm water runoff. The 5- year design storm event will be used to design the storm water management system, in accordance with Section D-4, "Water Control", of Part 2 of the Miami -Dade County Public Works Manual. - Based on preliminary calculations, it is anticipated that three (3) 24" drainage wells will provide sufficient capacity to dispose of the design 5-year 24-hour storm water runoff generated by the proposed development. Preliminary drainage computations for the project areas are provided in Attachment "B" Preliminary Drainage Well Calculations, which includes the basis for design. The final drainage design for the project should be in conformance with the requirements of the Miami -Dade County DERM Water Control Section, Florida Department of Environmental Protection, and other local, state and federal regulatory agencies having jurisdiction over the project. II. Water Distribution System The public water distribution system that would serve the project is owned and operated by the Miami -Dade Water and Sewer Department (MDWASD). Existing water mains in the vicinity of the project are shown below in the Table 3. Vista Biscayne Site Utility Study Page 3 • • • Table 3: Existing Water Mains (Per MDWASD Water Atlas Sheet) Loeatio Between Water::Main(s) NE 4tn Avenue NE 315` Street and NE 29th Street 12" D.I. NE 29th Street Along NE 29th St. east of NE 4th Avenue 12" D.T. Miami -Dade Water and Sewer Department (MDWASD) criteria normally require developers to construct a new 12-inch ductile iron (DI) water main along the frontage of the property. Currently, a 12-inch water main fronts the property along NE 29th Street. A final determination of the points of connection and requirements will not be provided by MDWASD until a Water and Sewer Agreement is requested by the owner. Water service meters will be installed by MDWASD forces at the owner's expense. See Attachment "C" for a copy of the MDWASD water atlas sheet for the project area. III. Sanitary Sewer Collection System Table 4 depicts the sanitary sewer mains owned and operated by Miami -Dade Water and Sewer Department (MDWASD), within the vicinity of the project. Vista Biscayne Site Utility Study Page 4 • • • Table 4: Existing Sanitary Sewer Mains (Per MDWASD Sewer Atlas Sheet) NE 4th Avenue NE 29th St. & NE 31st St. 8" Gravity Main NE 29th Street Along NE 29th St. east of NE 4`h Ave. 8" Gravity Main Similar to the watermain, an agreement with M-Dade County Water and Sewer Department (MDWASD) will be required for final determination of the points of connection. Public improvement requirements will not be provided by MDWASD until a Water and Sewer Agreement is requested by the owner. The proposed on -site sanitary sewer system for the property can be connected to the either of the existing mains abutting the property; provided that the line has capacity to handle the existing flows plus the additional flows contributed by the proposed project. A letter of availability and further coordination with MDWASD is recommended to verify the proposed sanitary sewer service connection points and requirements for this project. MDWASD may require upgrades to the sanitary sewer system, but this can not be determined without a request for a water and sewer agreement. A copy of the MDWASD Sewer Atlas sheet has been attached (See Attachment C). The flows from the existing MDWASD sanitary sewage mains on NE 4th Avenue and NE 29th Street are received by MDWASD Regional Pump Station #2, located at 925 Biscayne Boulevard. As of November 2004, this pump station is operating under capacity as established by the USEPA, and is not under any type of moratorium (see Attachment "D" Pump Station Monthly Information). At this time, it is not anticipated that any improvements to the regional pumping and/or transmission systems will be required to connect the proposed project. However, a final determination regarding the status of the existing transmission system and the need for possible improvements will not be made Vista Biscayne Site Utility Study Page 5 • • until construction plans are submitted to the Miami -Dade County DERM Wastewater Section and a Sanitary Sewage System Capacity Certification Letter is issued. The flows created by this project have been determined and are shown in Table 5. Table 5: Water & Sewer Flow Generation Apartments 41 units 200 gpd per unit 8,200 Total Anticipated Flow 8,200 gpd IV. Solid Waste Generation Solid waste generated by this project will be collected in standard on -site containers for refuse and recyclables. Regular pick-up service will be provided either by private hauling companies and/or by the City of Miami Solid Waste Department, who will transport the waste to Miami -Dade County's or private disposal and recycling facilities. The volumes of solid waste projected to be generated by the project are shown in Table 6. Vista Biscayne Site Utility Study Table 6: Solid Waste Generation Type of Occupancy Apartments Phase 1 Quantity 41 units 5lbs/unit/day Total Solid Waste Generated (Tons/I)ay} 0.10 Total Anticipated Solid Waste Generated 0.10 Page 6 • Attachment A Site Location Map • • N frb. 34TH ST Q 100.00.32ND ST ea a iG y-Hcfn and , inc. 1691 Michigan Avenue Suite 400 Miami Beach, Florida 33139 Phone: 305-673-2025 fax 305-673-4882 VISTA BISCAYNE SITE LOCATION MAP iROWARU !7 /64 Air, 4 Aft 1051 t JECt 4Bc1+ 'kb j,.EGENtY 2 tEsrimar�� NTER4'AL 1.0 •FCXIT, indicates #} MEAN SEA LEVEL. Kimsey -Horn and Associates, Jim 1691 Michigan Ave Suite 400 Miami Beach, Florida 33139 Phone: 305-673-2025 Fax: 305-673-4882 VISTA BISCAYNE AVERAGE OCTOBER GROUND WATER LEVEL 1960-75 Kimley-Horn and mates, Inc. 1691 Michigan Avenue Suite 400 Miami Beach, Florida 33139 Phone: 305-673-2025 Fax: 305-673-4882 VISTA BISCAYNE FLOOD CRITERIA MAP Kimley-Ham and Associates, Inc. :27===.40."4.4Xt:: 1691 Michigan Ave Suite 400 Miami Beach, Florida 33139 Phone: 305-673-2025 Fax: 305-673-4882 VISTA BISCAYNE F.LM. FLOOD INSURANCE RATE MAP • Attachment B Preliminary Drainage Well Calculations 0 • • • VISTA BISCAYNE City of Miami, Florida DRAINAGE CALCULATIONS: DRAINAGE WELLS (MASS DIAGRAM- DERM CRITERIA) 1. Site Data: A. Average October Water Table Elevation = 2.00 NGVD B. County Flood Criteria Elevation = 5.00 NGVD (County Flood Criteria Map, see Appendix A) C. F.I.R.M. or FEMA Base Flood Elevation = 900 ; Zone AE (Map No. 12025C01831, see Appendix A) D. Average Crown Road Elevation = 5 69 ' NGVD E. Average Existing Onsite Grade Elevation = 6.08 .: NGVD F. Proposed drainage inlet grate elevation = 6 (.` NGVD 2. Total Contributing Drainage Area (A): A. Impervious Areas: a) Asphalt and concrete pavement = b) Roof areas + 1/3 NE building corner = Total Impervious Area (Al) = 0.50 Acres .02 Acres 40: Acres 0.42 Acres (84%) B. Pervious areas: a) Green Areas = .08 Acres (16%) 3. Weighted Runoff Coefficient (C): Runoff Coefficient Impervious (C1) = 0 90: Runoff Coefficient Pervious (C2) = 0 30 C=[(A1 xC1)+(A2xC2)]IA; C= 0.80 C x A = Total Contributing Area; C x A = 0.40 Acres 4. Time required to generate one inch of runoff (per DERM Water Control Section D-4) Rainfall Intensity (I) = 308.51 [(48.6 x F-°'11) + t (0.5895 + F- 3)] Frequency (F) _ 5 years - Frequency Curve Q = CIA, V = Qt; V(i ii) = Qt(1 in.)' t(1 in) = Time to generate 1 inch of runoff Vo in.) = C1At(l in.) 1" x A = CIAt(l in) ; Solving for to in>, to � = 1" / (IC) Time to Generate one inch of run-off t(in) = 12.71 Min. Time to reach the inlet (tc.)10 00 `. Min. Total Time required to generate 1 in of runoff: = 22.71 Min. VISTA BISCAYNE DRAINAGE WELLS_Atlachment B_xis BASIN • • • 5. Cumulative Runoff (Inflow Mass Diagram) Time CxA (acres) 1 (inches) .. Q (CFS)' Accumulated Storm Runoff _ (CF) . . . (Min.) : (Sec.) 8 480 0.402 6.405 2.57 1,236 10 600 0.402 6.166 2.48 1,487 15 900 0.402 5.641 2.27 2,041 22.71 1363 0.402 4.986 2.00 2,732 30 1800 0.402 4.493 1.81 3,251 40 2400 0.402 3.956 1.59 3,817 50 3000 0.402 3.534 1.42 4,262 60 3600 0.402 3.193 1.28 4,622 90 5400 0.402 2.477 1.00 5,377 120 7200 0.402 2.023 0.81 5,855 180 10800 0.402 1.480 0.60 6,427 6. Drainage Well Design Discharge Rate: Based on well discharge rate of: 335 GPM/ft. Head DW-1 Lowest Inlet Rim Elev. (NGVD) ;. 6.00 ict.:Water Table elev. (NGVD) 2.00 Headlass'clue' to Higher SG; of Salt. Water: (ft.) 2.20 :Head Acting: on Well (f) 1.80 i.ell Discharge Rate (CFS) 1.34 Well Sim re Dimensions'. Width (ft Length (ft.) 120 Well Structure; Storage Volume (CF) 151.2 DW-1 6.00 2.00 2.20 1.80 1.34 l_0 151.2 DW-1 6.00 2.00 2.20 1.80 1.34 .:.12.0 151.2 Well Discharge Rate (CFS) 7. Detention Time: 4.03 Total Storage (CF) The drainage well structure must be designed to detain runoff for a minimum of 90 seconds prior to discharge. Qd = Design Runoff Rate (CFS) Vd = Detention Volume (CF) = Q x 90 sec. = Vdi = Detention Volume Per Well (CF) = W = Width of Well Structure (ft.) = L = Length of Well Structure (ft.) 2.00 CFS 180.40 CF 60.13 CF 7.0 ft. 12.0 ft. 453.60 Hm , is the minimum depth required from the top of well casing to the floor of the well box to achieve 90 second detention time: ll (ft.) = Vdi / (W x L) = 0.80 ft. Top of Well Casing Elev. = 4.00 Elevation at Floor of Well Box (NGVD) = Top of Well Casing Elev. - = 3.20 • • • 8. Excess storm water runoff excluding well structure storage: Time Well Discharge Rate (CFS) Accumulated Well Discharge Volume (CF} Accumulated Stony' Runoff (CF) • Total Overflow . Volume (CF) Min.) (Sec.) : 8 480 4.03 1,935 1,236 -699 10 600 4.03 2,418 1,487 -931 15 900 4.03 3,628 2,041 -1,587 22.71 1,362.82 4.03 5,493 2,732 -2,762 30 1800 4.03 7,255 3,251 -4,004 40 2400 4.03 9,674 3,817 -5,857 50 3000 4.03 12,092 4,262 -7,830 60 3600 4.03 14,511 4,622 -9,889 90 5400 4.03 21,766 5,377 -16,389 120 7200 4.03 29,021 5,855 -23,166 180 10800 4.03 43,532 6,427 -37,105 9. Excess storm water runoff including well structure storage: lTir.) (Sec.);: Accumulated Storrii. Runoff (CF) Storage in ell Structure (CF) Accumulated Well Discharge Volume (C Total Overflow Volume (CF). 8 10 15 22.71 30 40 50 60 90 120 180 480 600 900 1,362.82 1800 2400 3000 3600 5400 7200 10800 1,236 1,487 2,041 2,732 3,251 3,817 4,262 4,622 5,377 5,855 6,427 454 454 454 454 454 454 454 454 454 454 454 1,935 2,418 3,628 5,493 7,255 9,674 12,092 14,511 21,766 29,021 43,532 -1,152.48 -1,384.72 -2,040.29 -3,215.15 -4,457.67 -6,310.23 -8,283,57 - 10,342,75 - 16,842.71 -23,619.53 -37,558.20 Safety Factor 1 2.01% Safety Factor 2.41% • Attachment C Existing Utility Records • • 60 251 _ 261-7 - 1813 252 .4c 1622 1 tiE 32. ST 239 Z39 237, -I . 230 = 235 75311 521- 0 18 6 8311- 7,20 220 if 371 0 170 177 14€ 31 6/1 i0 2:31 2020 16-00 ' 'oft ilkfti 200, 123/ -; Er A' a i 22'...01 1,51051 521 ,g33 234 = 2-1-0%.15492- Tei-PROJECI 172 Ill r ir I 70 1 ) , , 10 14 <744 1 ' • , „,, , 9 NE 26 ST , 2308 100. ; 1.04 .10.4' -i; • 'C 0' -4-Cie OVEN 1533 1669 LOCATLON 212 210 211 199 1691 Michigan Avenue Suite 400 Miami, Florida 33143 IGmlotHorn and Associab3s, Inc. Phone: 305-662.6445 Fax 305-662.6492 VISTA BISCAYNE MDWASD SEWER ATLAS SHEET • 12..-ri IGniey-Hom and Associates, kr. 1691 Michigan Avenue Suite 400 Miami, Florida 33143 Phone: 305-662.6445 Fox: 305-662.6492 VISTA BISCAYNE MDWASD WATER ATLAS SHEET • Attachment D Pump Station Monthly Information • • 12/26/2004 11/23/2004 10/25/2004 09/24/2004 08/25/2004 07/27/2004 06/25/2004 GOLD/M GOLD/D GOLD/ T • • Pump Station Monthly Information <P1Nn ReviE Station..30 -0002 Atlas Pg..E13 Moratorium.. MIANI DADE WATER & SEWER DEPARTMENT 0 Addr. .. 925 BISCAYNE BLVD Moratorium effective since / / Sec -Township -Range..., 31-53-42 Genr. ET clock.Y Te1m.Y #pumps 5 Puznp Type.A Stn C1ass.M Speea.R Hrspwr.-+- Res flow(g-pd) Plans.. 1,779,363 Plats.. 0 Extens. 0 Proj Napot 4.32 hrs 3.08 hrs 3.08 hrs % Cap 43.20 30.80 30.80 Yearly NAPOT (hrs) 3.( Stn Gross Capacity(gpd).. Station Reduction Factor Stn Net Cap Certif(gpd)., Stn Net Capacity(gpd).... 34,560,0( Indicated Flows (gpd) 4,435,2( 57,600,0( 0.E Date Mo.NAPOT Avg Daily Flows Rgd # Coicuuents Fig Pmp 2.80 11.21 0.00 Y 5 3.09 12.34 0.00 Y 5 3.28 13.10 0.00 Y 5 3.14 12.5E 0.00 Y 5 3.38 13.50 0.00 Y 5 2.82 11.28 0.00 Y S 2.79 11.16 0.00 Y 5 Signature..LEAI.G Sign, Date..03/17/2003 13:52:24.01 Station I<m>proveznent GOLD/S <S>tation Inform. GOI,DfU <D>pstream. Stat <n>ownstream Station GOL13/P <P>ump Infoiivat: Sewer Cer<t>jfication 'd • l 6 '0 INVSt :Ol SOH 'l 'Ed • • ent. *2005020209563996*C,ABALP * This is not an official doc M Stet Station Station Current Delta Project R Type Owner Number ET (Hrs) ET (Hrs) ET (HI: Proposed Number of gallons (gpd): 8200 ******4e*********************** Downstream Stations *'************************hi OK A5RM+ 30 0002 4.32 0.01 4. AC 30 CD 1001.61 0.00 1001. AC 30 RS 1001.55 0.00 1001, IN 30 RS95APR 1001.34 0.00 1001. IN 30 RS94MAR 1001.44 0.00 1001. .d G6'O WvS1:Ol SOH `Z _SJ3