Loading...
HomeMy WebLinkAboutII Project DescriptionPARAMOUNT PARK MAJOR USE SPECIAL PERMIT PROJECT DESCRIPTION ARTICLE II. Project Description A. Zoning Ordinance No. 11000 1. Section 1304.2.1 Application forms; supplementary materials 2. Section 1702.2.1 General Report 3. Section 1702.2.2 Major Use Special Permit Concept Plan 4. Section 1702.2.3 Development Impact Study • • • • • MAJOR USE SPECIAL PERMIT 1 Section 1304.1.1 Application forms; supplementary materials (a) Statements of ownership and control of the proposed development of activity. The Disclosure of Ownership and Ownership Affidavit are provided in Article I. (b) Statement describing in detail the character and intended use of the development or activity. The property is located on the block bounded by Biscayne Boulevard to the east, NE 7th Street to the south, NE 2nd Avenue to the west and NE 8th Street to the north. The property is currently zoned SD-6. The intent of the project is to contribute to the pedestrian environment of Biscayne Boulevard by enhancing the urban character of the neighborhood with the proposed massing distribution and by providing residential, retail, restaurant, fitness and recreational amenities to the future residents as well as the neighborhood residents, tourists and commercial visitors. Paramount Park (the "Project") at 700 Biscayne Boulevard will comprise a high-rise Residential Tower with a total of 467 residential condominium units and 120 hotel -condominium units lining the east, north and south sides of the Parking Garage. The Parking Garage is located on 10 levels with a total of 818 parking spaces. In addition to the residential and hotel units the project will also comprise of a total of 12,947 square feet of street level restaurant and commercial use along Biscayne Boulevard, NE 7th Street, NE 2nd Avenue and NE 8th Street. The program is distributed by level as follows: • Levels 1 and 2: Two-story residential lobby, a separate two- story hotel -condominium lobby facing Biscayne Boulevard, building service rooms on two levels, FPL transformer vault, access up to the Parking Garage and enclosed loading areas. • Levels 3 to 12: 120 Hotel -condominium units line the parking garage levels. (There is no Level 13 for marketing reasons.) • Level 14: Residential amenities for the condominium residents including a party room, lounge, cafe, fitness center, recreational pool, lap pool, spa and landscaped deck. C:IBocuments and Settings\avinnj\Local Settings.Temparary Internet Ft es1OLK34ML SPdac-022405.DOC Page t • • • • Levels 15 to 17: Immediately above the Amenity Level, the three volumes of the tower extend up with voids between them. These levels have six units each level served by a total of six semi -private passenger elevators and one service elevator. (Two additional elevator cores run express through these levels.) • Levels 18 to 61: The typical residential floor plates will have ten units each level served by at total of eight semi -private passenger elevators and one service elevator. • Levels 62 to 65: The three volumes extend above the typical floors with the "connector" units and will consist of six units each level served by six semi -private passenger elevators and one service elevator. • Levels 66 to 68: The center tower extends higher than the two flanking towers and will consist of two penthouse residential units each level served by one service elevator. • The roof level will consist of building service areas. The Project will be situated on the entire city block with frontage along Biscayne Boulevard, NE 7th Street, NE 2nd Avenue and NE 8th Street. The location of the site across the street from Biscayne Bay and the American Airlines Arena will provide maximum views east to the bay and west to the city and sunset views. Its downtown location across from the arena and between the Performing Arts Center a few blocks to the north and Bayside to the south provides open pedestrian access, which the Project augments by providing a landscaped stepped terrace to a restaurant, cafe and retail facing Biscayne Boulevard, NE 7th Street, NE 2nd Avenue and NE 8th Street. The residential lobby will be accessed from a formal entry drive off of NE 7th Street, as well as a pedestrian access from Biscayne Boulevard. The residential elevator lobbies can also be accessed from the parking garage levels. The off-street loading area is accessed from N.E. 8th Street and is fully enclosed within the building envelope. The Project provides for commercial frontage along Biscayne Boulevard, NE 7th Street, NE 2nd Avenue and NE 8th Street that complements the pedestrian activity of the neighboring Biscayne Boulevard buildings. Drawings showing the architectural character and location of the intended uses are included under Tab 6 of the Supporting Documents. C:lDocuments and SetlingslavinojlLoca! SettingslTenvporary Internet Piles lOLK341119t1SPdee-022405. DOC Page 2 0 (c) • • General location map, showing relation of the site or activity for which special permit is sought to major streets, schools, existing utilities, shopping areas, important physical features in and adjoining the project or activity and the like . The following exhibits are included with the Major Use Special Permit Application: (1) Aerial: Aerial photograph of the surrounding area indicating the project site is provided on AO.00. (2) Area Context Map/Site Aerial: Map of the project area indicating buildings that surround the site and their functions is provided on AO.00. Location Map: Map of the surrounding street system indicating the project location is provided on A1.00. (d) A site plan containing the title of the project and the names of the project planner and developer, date, and north arrow and, based on an exact survey of the property drawn to a scale of sufficient size to show: (3) The general information requested is shown on the Context Plans (A0.00), Site Plan (A1.00) and Ground Floor Plan (A1.01) provided under Tab 6 of the Supporting Documents. The site plan includes the following: (1) Boundaries of the project, any existing streets, buildings, watercourses, easements and section lines; The boundaries of the Project and the location of existing streets and easements are shown on A1.00 and the Survey located under Tab 5 of the Supporting Documents. Views of the existing site conditions and neighboring streets are shown on A0.02 and A0.03 located under Tab 6 of the Supporting Documents. (2) Exact location of all buildings and structures; The exact location of the existing buildings located on the property are shown on the Boundary Survey under Tab 5. The location of the building to be constructed is shown on the Location Plan Sheet A1.00 and the Ground Floor Plan Sheet A1.01 located under Tab 6 of the Supporting CADOeuments and Setdngslavinoj\Local Settings\ Temporary Internet FileslOLK34i,Y[l1SPdoa622415DOC Page 3 • • • (3) Documents. The location of the building within the overall neighborhood is shown on the Aerial Context Plan A0.00. Access and traffic flow and how vehicular traffic will be separated from pedestrian and other types of traffic; Vehicular access for the Project will be from N.E. 7th Street to the entry drop-off, N.E. 2nd Avenue to the Parking Garage ramp and N.E. 8th Street to the off-street loading area. Commercial parking is on Level 3 (the first parking garage level), while the upper levels are residential parking. A detailed analysis of the site access and traffic flow is provided in the Traffic Impact Analysis located under Tab 2 of the Supporting Documents. The Project will be accessed by pedestrians from Biscayne Boulevard (commercial, hotel and residential), N.E. 7th Street (residential and commercial) and N.E. 2nd Avenue (commercial). Vehicular curb cuts have been avoided along Biscayne Boulevard to provide maximum unobstructed pedestrian activity along this major artery. The landscaped stepped terrace along the Biscayne Boulevard commercial frontage create a pedestrian friendly urban environment. (4) Off-street parking and off-street loading areas; The parking structure will have 818 parking spaces which will support the entire development. The off-street parking facility is located within the parking garage levels, Levels 3 through 12, with internal vehicular circulation. The garage is shown on Sheets A1.02 and A1.03, provided under Tab 6 of the Supporting Documents. The parking garage is fully lined with ten -story hotel use along Biscayne Boulevard, N.E. 7th Street and N.E. 8th Street and along N.E. 2nd Avenue with a designed glazed "cube" system that matches the glazed "cube" system of the hotel liner. The Zoning Ordinance requires five loading bays, four at 12 ft. by 35 ft and one at 12 ft. by 55 ft. The project is designed with five loading bays, two at 12 ft. by 35 ft., two at 12 ft. by 20 ft. and one at 12 ft. by 15 ft. The vertical clearance for all loading bays is a minimum of 14 feet. The enclosed Loading area and Service areas are shown C:1Documents and Seitingsla,lnoj;Local Settings\Temparary Internet Files\OLK3AL44USPdoc..O22405.LDOC Page 4 • • • on the Ground Level Plan, Sheet A1.01, under Tab 6 of the Supporting Documents. (5) Recreational facilities locations; Landscaped stepped terrace areas are provided on the ground level facing Biscayne Boulevard for outdoor cafe and restaurant seating. The Level 14 Residential Amenity Deck has a recreational pool, lap pool, spa and sun deck as well as the Club Room, Lounge, Cafe and Fitness Center. The hotel component has its own interior amenities. These will serve as recreation areas for the development as well as the public on the street level. These facilities are shown on the architectural Plans A1.01 and A1.04 and on the Landscape Plans L1.00 and L1.01 under Tab 6 of the Supporting Documents. (6) Screens and buffers; The landscaping along Biscayne Boulevard will be filled with shade trees accented by palm trees creating a full canopy coverage for the public and cafe users. The frontage along N.E. 7th Terrace, N.E. 2nd Avenue and N.E. 8th Street will also have shade trees as indicated on the Architectural and Landscape Plans located under Tab 6 of the Supporting Documents. The ground level building service areas and the parking levels are screened from public view as shown on A1.01 and the east, south, west and north elevations A2.01, A2.02, A2.03 and A2.04. The tower facade design is designed to screen the rooftop building service areas and equipment from view. (7) Refuse collections areas; Waste collection will be provided with a fully enclosed containerized trash system located within the off-street service area in the building, which is not visible from the street. These facilities are shown on the Ground Level Plan, Sheet A1.01, located under Tab 6 of the Supporting Documents. (8) Access to utilities and points of utilities hookups; CU3acusnents and Settingslavinej Local Seitingaffemporaiy Internet FileslOLK341MUSPdoc-022405_DOC Page 5 Access and connections to site utilities are discussed in the Site Utility Study located under Tab 3 of the Supporting Documents. (e) Tabulations of total gross acreage in the project and the percentages thereof proposed to be devoted to: (1) The various permitted uses; Gross acreage: Total developed area: Residential area: Commercial area: 148,694 square feet = 3.41 acres 1,128,425 square feet 1,115,478 square feet = 99% of total 12,947 square feet = 1% of total Green space required: 17,981 square feet Green space provided: 26,394 square feet Urban Plaza required: 7,435 square feet Urban Plaza provided: 13,067 square feet (2) Ground coverage by structures Ground coverage by the structure is 36% of the total gross lot Area (54,223 square foot building footprint compared to 148,694 square foot gross lot area). (f) Tabulation showing the following: (1) The derivation of numbers of off-street parking and off-street loading spaces shown in (d) above. The total number of off-street parking spaces required is 514 spaces and the total number of spaces provided will be 818. Of those totals, the residential uses require 497 spaces and 801 spaces are provided (171 of which are tandem spaces); the commercial uses require 17 spaces and 17 spaces are provided. Derivation of the number of off-street parking is shown on the Development Program & Site Data sheet, located under Tab 6. (2) Total project density in dwelling units per acre. The Project is providing 467 dwelling units and 120 hotel units (equal to 60 dwelling units) which is as per the maximum density of 300 units per acre, or 527 dwelling units maximum, set forth in the SD-6 Zoning Ordinance for the Project. C:1Doctiments and Settings\atinoj\Local Settings\Temporary Internet Files10LK34\NMUSPdoc-022405.DOC Page 6 • • • (g) If common facilities (such as recreation areas of structures, private streets, common open space, etc.) are to be provided for the development, statements as to how such common facilities are to be provided and permanently maintained. All common facilities provided will be maintained initially by the Owner. Common facilities of the residential tower will be maintained by a condominium association. (h) Storm drainage and sanitary sewerage plans. Storm drainage, water distribution, waste water and solid waste generation provisions are discussed in the Site Utility Study located under Tab 3 of the Supporting Documents. (i) Architectural definitions for buildings in the development; exact number of dwelling units, sizes, and types, together with typical floor plans of each type. The residential tower consists of a total of 467 units (86 one - bedroom plus den units, 180 two -bedroom units, 94 two -bedroom plus den units and 107 three -bedroom units). Detailed information of all uses are found on the Development Program & Site Data sheet, included under Tab 6 of the Supporting Documents. Typical floor plans for the residential levels are shown on the Architectural Floor Plans A1.05 and A1.06. All drawings are located under Tab 6 of the Supporting Documents. (j) Plans for signs, if any. Signage for the Project will include signage for the hotel and commercial components on Biscayne Boulevard (East Elevation) as well as a sign for the residential building over the entry drive on the North Elevation. Signage locations are indicated on the East and North Elevations on sheets A2.01, A2.01 a, A2.04 and A2.04a. (k) Landscaping plan, including types, sizes and locations of vegetation and decorative shrubbery, and showing provisions for irrigation and future maintenance. The landscape plans showing vegetation are found on the Landscape Plans, Sheets L1.00 and L1.01. All landscape plans are located under Tab 6 of the Supporting Documents. (I) Plans for recreation facilities, if any, including location and general description of buildings for such use. CAT/ocuments and ,SettingslavinojlLacai Settings lTemporary 'Internet Fileslt3LK341MUSRdoc-022405.BOC Page 7 • • • (m) Landscaped stepped terrace areas are provided on the ground level facing Biscayne Boulevard for outdoor cafe and restaurant seating. The expansive landscaped Level 14 Residential Amenity Deck includes a recreational pool, lap pool, spa and sun deck as well as the Club Room, Lounge, Cafe and Fitness Center. The hotel component has its own interior amenities on Level 3 that include a Lounge, Fitness Center and Business Center. These will serve as recreation areas for the development as well as the public on the street level. These facilities are shown on the architectural Plans A1.01 and A1.04 and on the Landscape Plans L1.00 and L1.01 under Tab 6 of the Supporting Documents. Such additional data, maps, plans, or statements as may be required for the particular use or activity involved. The drawings submitted with this application, which detail the statistics, floor plans, elevations, sections and renderings for the Project are provided under Tab 6 of the Supporting Documents. (n) Such additional data as the applicant may believe is pertinent to the proper consideration of the site and development plan. Sections and elevations depicting the architectural character of the building are shown on the overall Building Elevations (Sheets A2.01 through A2.04), enlarged Podium Elevations (Sheets A2.01 a through A2.04a), Building Section (Sheets A3.01) and rendering (A4.00 and A4.01). All elevations, sections and renderings are located under Tab 6 of the Supporting Documents. (o) Lighting Concept Narrative The lighting scheme will reinforce and accent architectural features as well as signature elements to create visual interest, enhancing the dynamic quality of each elevation as seen from the street and surrounding buildings. 2. Section 1702.2.1 General Report. (a) Property ownership and beneficial interest within the boundaries of the area proposed for Major Use Special Permit. Statement of Ownership and beneficial interest within the boundaries of the area proposed for Major Use Special Permit are provided in Article 1. C'.1Docvrnents and Settings .av,naj•Local Settings!Temporary Internet Files.OLK341M1SPdoc-O22405.DOC Page 8 • • • (b) The nature of the unified interest or control. The nature of unified interest or control is indicated in Article 1. (c) Survey of the proposed area showing property lines and ownership. A copy of the Survey is included under Tab 5 of the Supporting Documents. (d) Map of existing features, including streets, alleys, easements, utilities lines, existing land use, general topography, and physical features. The existing site features and utility lines are shown on the Boundary Survey of the property located under Tab 5. The site features and the utilities are also described in the Site Utility Study, located under Tab 3 of the Supporting Documents. Views of the existing site conditions and neighboring streets are shown on A0.02 and A0.03 located under Tab 6 of the Supporting Documents. (e) (fl Materials to demonstrate the relationship of the elements listed in (4) preceding to surrounding area characteristics. The Renderings of the Project show it in context with the neighborhood, as shown on A4.00 and A4.01 located under Tab 6 of the Supporting Documents. Existing zoning and adopted comprehensive plan designations for the area on and around the lands proposed for Major Use Special Permit. The existing zoning designation for the property is identified on Page 23 of the Zoning Atlas Map. The current zoning designation for the property is SD-6. The comprehensive plan future land use designation for the property is Restricted Commercial. 3. Section 1702.2.2 Major Use Special Permit Concept Plan. (a) Relationships of the concept plan to surrounding existing and proposed future uses, activities, systems, and facilities (transportation, recreation, view corridors, pedestrian systems, service systems and similar uses. Section 1(b) contains a written narrative of the Project outlining proposed uses, activities and architectural character. This narrative also contains descriptions of the project's relationship to C:lllocuments and Set€ings\avinojltocal SettingsVremparary Internet Files1OLK341.MUSPdoc-0224O5.DOC Page 9 • • • traffic, pedestrian movements, and transportation access. Building elevations, sections and perspectives showing the proposed materials, vertical profile and height, and orientation to streets are included in the drawings submitted with this Application. The list of drawings submitted is found under Tab 6 of the Supporting Documents. (b) Existing zoning and adopted comprehensive plan principles and designations. This project conforms to the SD-6 zoning district designations for this property. 4. Section 1702,2.3 Developmental Impact Study. (a) A traffic analysis shall be submitted for an area including the major intersections to be significantly impacted by the site and other intersections and/ or corridors specified by the City or the City's consultant. The Traffic Impact Analysis is included under Tab 2 of the Supporting Documents. (b) Economic impact data shall be provided, including estimates for construction costs, construction employment, and permanent employment and shall demonstrate that the proposed development is favorable to the economy, public services, environment and housing supply of the City. The Economic Impact Study is included under Tab 4 of the Supporting Documents. (c) A housing impact assessment. Over the last several years prices of urban housing have increased dramatically, despite the recent slow down in the economy. Subsequently, a substantial amount of people within metropolitan areas have begun to return to the city to live. This has created a shortage of multi -family housing along with an upward surge of housing prices. Contrarily, the cost of construction has not kept pace with these increases, which has made it economically affordable to construct new buildings for sale. This pattern remains the same in South Florida where there continues to be an increased demand for housing, particularly in Miami -Dade County. ::00 ]ATCBOCSAMIAMIV1622a091I Page Eo • • • (d) A description of proposed energy conservation measures shall be provided, including only those measures that are proposed in addition to the minimum requirements in State Energy Code. Architecturally, the building envelope will be comprised of glazing, concrete walls and a concrete and insulated roof. Tinted laminated reflective glass will be used throughout the building to minimize the solar heat load. Electrically, all exterior and landscape lighting will be controlled by means of time clocks and photocell switches. Energy saving lamps, ballasts and fixtures are being considered at cores and public spaces. (e) Historic Buildings There are no designated existing historic structures located on the property. (f) Environmental Zone The Property is not located within an environmental preservation district. ',ODM A FCDOCS .MIAMI1167240911 Page t