HomeMy WebLinkAboutArticle II - Project DescriptionMARQUIS
MAJOR USE SPECIAL PERMIT
PROJECT DESCRIPTION
ARTICLE It.
Project Description
A. Zoning Ordinance No. 11000
1. Section 1304.2.1 Application forms; supplementary
materials
2. Section 1702.2.1 General Report
3. Section 1702.2.2 Major Use Special Permit Concept Plan
4. Section 1702.2.3 Development Impact Study
e
•
•
o
o
MARQUIS
MAJOR USE SPECIAL PERMIT
Section 1304.1.1 Application forms; supplementary materials
(a)
Statements of ownership and control of the proposed
development of activity.
The Disclosure of Ownership and Ownership Affidavit are
provided in Article I.
(b) Statement describing in detail the character and intended use
of the development or activity.
MARQUIS will be a 63-story residential building with 310
residential units, 48 hotel units (equivalent of 24 residential units),
street -level retail and 429 parking spaces. The project is located
at 1100 Biscayne Boulevard, Miami, Florida. The development
consists of a parcel with a net lot area of 48,607 square feet
(1.117 acres). The gross lot area is 140,635 square feet (3.23
acres). The maximum FAR is 8.4 and the maximum buildable
FAR area is 1,181,334 square feet. The property is subject to
dedications along two frontages: 12'-6" on NE 11th Street and 17'-
6" on NE 2nd Avenue.
The property fronts NE 11th Terrace on the north, Biscayne
Boulevard to the east, NE 11th Street to the south and NE 2"d
Avenue to the west. Bicentennial Park / Museum Park occupies
the parcel immediately to the east across Biscayne Boulevard and
the 11th Street Metromover Station is located directly to the west
across NE 2nd Avenue. The zoning designation for the property is
SD-6 and is located within the Southeast Overtown / Park West
Overlay District which allows a maximum of 300 units / acre.
Ground Level Uses:
The main entrance to the project is through a beautifully
landscaped porte-cochere off NE 11th Street. The ground floor will
contain the residential lobby, hotel lower lobby, and restaurant
which all front Biscayne Boulevard. Pedestrians will be able to
access the property directly from Biscayne Boulevard by passing
through a deep, landscaped urban plaza, a result of the
forthcoming realignment to Biscayne Boulevard. Residents and
guests alike will enjoy unsurpassed views of Biscayne Bay and
Museum Park from the elevated dining terrace. Entrance to the
parking garage will also be from NE 11th Street. Loading is
provided via a pass -through condition with the ingress located on
o
o
o
NE 11 to Terrace and the egress on NE 11th Street. All loading
operations occur within the building envelope. Access to
mechanical rooms is located along NE 11th Terrace.
Podium:
The podium contains a 48-key boutique hotel and sufficient
parking for the entire development. The 2nd floor will contain hotel
upper lobby, lobby lounge and parking. A mezzanine will contain
the hotel business center, meeting rooms and parking. The 3rd
through 10th levels will contain hotel units and parking areas. The
11t' level will contain storage, parking, exercise rooms and a spa.
The north, south and west faces of the podium structure will be
clad in an open-air, decorative metal mesh. In addition, art
screens are contemplated to comply with the revised Signage
Ordinance in the City of Miami Zoning Code.
Pool Deck:
The 12th floor will contain pool deck, residential party room,
planters and a water garden. It is lined on three sides by two-story
residential townhouses which provide a sense of enclosure to the
deck. An Asian -inspired, landscaped water garden envelops the
poolside activities, thereby affording a level of privacy to the
townhouses. The lap pool passes through an eight -story void in
the tower and projects slightly toward Biscayne Boulevard,
providing views through to the Bay and beyond to South Beach.
The void will contain dramatic illumination at night.
Tower:
The 13th through 63rd levels will contain the remaining residential
units. The slender, L-shaped tower is oriented to maximize views
of Biscayne Bay and the Performing Arts Center District. The
tower itself is composed of a series of interlocking parallelograms
that create variation in the form. The tower is clad entirely in clear
glass with a slight blue tint. Floor slab edges are expressed and
white in color. Continuous, glass -railed balconies project along the
east and north faces of the building. Differences in ceiling height
between single -story and two-story units create visual interest in
the balconies. A glass elevator core along the north facade
provides passers-by with a glimpse of the tower's inner workings
and serves as an iconic feature to the development.
A vertical projection creates deeper balconies for upper -level
residents along the northeast edge of the tower. This grid frame
o
o
•
will be illuminated at night to serve as a beacon to the Arts District
and downtown Miami.
Rooftop terraces are featured at the upper penthouse level. The
"Marquis" penthouse occupies the tower's highest level and
affords its resident with an unparalleled, panoramic view of
greater Miami and the beaches.
Drawings showing the architectural character and location of the
intended uses are included under Tab 6 of the Supporting
Documents.
(c) General location map, showing relation of the site or activity
for which special permit is sought to major streets, schools,
existing utilities, shopping areas, important physical features
in and adjoining the project or activity and the like.
The following exhibits are included with the Major Use Special
Permit Application:
(1) Aerial: Aerial photograph of the surrounding area
indicating the project site.
(2) Area Context Map/Site Aerial: Map of the project area
indicating buildings and their functions that surround the
site.
(3)
Location Map: Map of the surrounding street system
indicating the project location.
(d) A site plan containing the title of the project and the names of
the project planner and developer, date, and north arrow and,
based on an exact survey of the property drawn to a scale of
sufficient size to show:
The general information requested is shown on the Ground/Site
Plan, Sheets A0.08 and A0.09, provided under Tab 6 of the
Supporting Documents. The site plan includes the following:
Boundaries of the project, any existing streets,
buildings, watercourses, easements and section
lines;
The boundaries of the project and the location of existing
streets and easements are shown on the Survey located
under Tab 5 of the Supporting Documents.
o
•
•
(2) Exact location of all buildings and structures;
The exact location of all existing buildings located on the
property is shown on the Boundary Survey under Tab 5.
The location of the building to be constructed is shown on
the Site Plan, Sheet A0.08, located under Tab 6 of the
Supporting Documents.
(3)
Access and traffic flow and how vehicular traffic will
be separated from pedestrian and other types of
traffic;
Vehicular access for the project is from NE 11 th Street.
Access to the parking garage is located through the
covered drop-off. The service drive and loading areas for
the project create a pass -through condition linking NE 11 th
Terrace and NE 11th Street along the western edge of the
property.
A detailed analysis of the site access and traffic flow is
provided in the Traffic Impact Analysis located under Tab
2 of the Supporting Documents.
(4) Offstreet parking and offstreet loading areas;
The offstreet parking facility will include an 11-level
parking structure with 429 parking spaces. The garage is
shown on Sheets A1.02 through A1.05, provided under
Tab 6 of the Supporting Documents.
(5)
The Zoning Ordinance requires six (6) loading bays.
There will be four (_4_) loading bay 12 ft. x 35 ft. and two
(2) berths 10 feet x 20 feet. The clearance for all loading
bays is 15 feet. Service areas are shown on the A1.01
Plan, under Tab 6 of the Supporting Documents.
Recreational facilities locations;
Levels 11 and 12 will serve as a recreation deck for the
development and will include indoor and outdoor
amenities. They will include indoor recreational facilities
such as lounge and spa, lockers, bathrooms and showers,
sauna and Jacuzzi. Exterior facilities will include a pool,
lap pool and roof deck with a water garden and planters.
The tower roof, Level 62, will serve as private terraces for
the penthouse units. Each terrace will include a hot tub
and a lounge roof deck with planters.
•
•
•
These facilities are shown on the A1.06 and A1.16 located
under Tab 6 of the Supporting Documents.
(6) Screens and buffers;
Landscaped areas are indicated on the Plan, Sheet L1.01,
L1.03, A1.01 and A1.06, located under Tab 6 of the
Supporting Documents.
(7) Refuse collections areas;
Waste collection will be provided by a containerized
compactor system located within the service area. In
addition, the project will have a high rise recycling system.
The building will include a dry wash, refrigerated garbage
rooms and can wash. These facilities are shown on the
Plan, Sheet A1.01 and A1.02, located under Tab 6 of the
Supporting Documents.
•
•
•
(8) Access to utilities and points of utilities hookups.
Access and connections to site utilities are discussed in
the Site Utility Study located under Tab 3 of the
Supporting Documents.
(e) Tabulations of total gross acreage in the project and the
percentages thereof proposed to be devoted to:
(1) The various permitted uses:
Residential Sq. Ft. = 675,420 S.F.
Non-residential Sq. Ft. = 5,765 S.F.
(2) Ground coverage by structures:
Building Footprint = 33,325 S.F.
Ground coverage by the structures is 23.7% of the total gross lot
area.
(f) Tabulation showing the following:
(1) The derivation of numbers of offstreet parking and
offstreet loading spaces shown in (d) above;
(g)
The total number of offstreet parking spaces required is 330
spaces and the total number of spaces provided is 429 spaces.
Derivation of the number of offstreet parking is shown under the
A0.01 Plan, within the Project Summary, located under Tab 6.
(2) Total project density in dwelling units per acre.
As per SD-6 Southeast Overtown / Parkwest Overlay
District the maximum project density is 300 units per acre.
The designated site is 1.117 acres, which allows for the
construction of 334 units. This project will provide 310
residential units and 48 hotel units (equivalent of 24
residential units).
If common facilities (such as recreation areas of structures,
private streets, common open space, etc.) are to be provided
for the development, statements as to how such common
facilities are to be provided and permanently maintained.
•
•
•
All common facilities provided will be maintained by the Owner.
(h) Storm drainage and sanitary sewerage plans.
Storm drainage, water distribution, waste water and solid waste
generation provisions are discussed in the Site Utility Study
located under Tab 3 of the Supporting Documents.
Architectural definitions for buildings in the development;
exact number of dwelling units, sizes, and types, together
with typical floor plans of each type.
Detailed information and breakdown of square footage of all uses
are found under Project Criteria within The Project Summary,
included under Tab 6 of the Supporting Documents. Typical floor
plans for residential units are shown on the Typical Residential
Floor Plans. All drawings are located under Tab 6 of the
Supporting Documents.
(i)
(j) Plans for signs, if any.
The project will obtain signage approval at a later date.
(k) Landscaping plan, including types, sizes and locations of
vegetation and decorative shrubbery, and showing
provisions for irrigation and future maintenance.
The landscape plans showing vegetation are found on the L1.01,
L1.02, L1.03 and L1.04. All landscape plans are located under
Tab 6 of the Supporting Documents.
(I) Plans for recreation facilities, if any, including location and
general description of buildings for such use.
The easternmost portion of Level 11 will contain an exercise room
and spa. The 1 21n Level Roof Area will contain a pool, lap pool,
resident party room and recreation deck.
Such additional data, maps, plans, or statements as may be
required for the particular use or activity involved.
The details of the spaces and calculations used to compute the
Floor Area Ratio (FAR) are shown on the Sheet A0.01, provided
under Tab 6 of the Supporting Documents.
(n) Such additional data as the applicant may believe is pertinent
to the proper consideration of the site and development plan.
(m)
•
•
•
Elevations depicting the architectural character of the building are
shown on the Buildings Elevations. Sheets A2.01 through A2.05.
All elevations are located under Tab 6 of the Supporting
Documents.
2. Section 1702.2.1 General Report.
(1)
Property ownership and beneficial interest within the
boundaries of the area proposed for Major Use Special
Permit.
Statement of Ownership and beneficial interest within the
boundaries of the area proposed for Major Use Special Permit are
provided in Article I.
(2) The nature of the unified interest or control.
The nature of unified interest or control is indicated in Article I.
(3) Survey of the proposed area showing property lines and
ownership.
A copy of the Surveys is included under Tab 5 of the Supporting
Documents.
(4) Map of existing features, including streets, alleys, easements,
utilities lines, existing land use, general topography, and
physical features.
The existing site features and utility lines are shown on the
Boundary Survey of the property located under Tab 5. The site
features and the utilities are also described in the Site Utility
Study, located under Tab 3 of the Supporting Documents.
(5)
Materials to demonstrate the relationship of the elements
listed in (4) preceding to surrounding area characteristics.
The drawings submitted with this Application are located under
Tab 6 of the Supporting Documents.
(6) Existing zoning and adopted comprehensive plan
designations for the area on and around the lands proposed
for Major Use Special Permit.
The existing zoning designation for the property pursuant to City
of Miami Ordinance No. 11000 and Plat Book 30, at Page 12 of
the Public Records of Miami -Dade County, Florida. (which is
located in Article I), indicates the existing and surrounding zoning.
•
•
o
The zoning designation for the property is SD-6 Southeast
Overtown / Parkwest Overlay District. The Comprehensive Plan
Future Land Use designation for the property is Residential High
Density. The zoning and the comprehensive plan designations are
consistent with one another.
3. Section 1702.2.2 Major Use Special Permit Concept Plan.
a. Relationships of the concept plan to surrounding existing
and proposed future uses, activities, systems, and facilities
(transportation, recreation, view corridors, pedestrian
systems, service systems and similar uses.
Article II contains a written narrative of this project outlining
proposed uses, activities and architectural character. This
narrative also contains descriptions of the project's relationship to
traffic, pedestrian movements, and transportation access.
Building elevations, sections and perspectives showing the
proposed materials, vertical profile and height, and orientation to
streets are included in the drawings submitted with this
Application. The list of drawings submitted is found under Tab 6
of the Supporting Documents.
b. Existing zoning and adopted comprehensive plan principles
and designations.
The project conforms to the SD-6 Southeast Overtown /
Parkwest overlay zoning district designation for the property. The
comprehensive plan future land use designation conforms to the
land use designation currently in effect for the property.
4. Section 1702.2.3 Developmental Impact Study.
(a) A traffic analysis shall be submitted for an area within
approximately 1/4 mile of the site, or an area including the
major intersections to be impacted by the site, whichever is
larger.
The Traffic Impact Analysis is included under Tab 2 of the
Supporting Documents.
(b) Economic impact data shall be provided, including estimates
for construction costs, construction employment, and
permanent employment and shall demonstrate that the
proposed development is favorable to the economy, public
services, environment and housing supply of the City.
•
•
•
10
The Economic Impact Study is included under Tab 4 of the
Supporting Documents.
(c) A housing impact assessment.
Over the last several years prices of urban housing have
increased dramatically; despite the recent slow down in the
economy. Subsequently, a substantial amount of people within
metropolitan areas has begun to return to the city to live. This
has created a shortage of multi -family housing along with an
upward surge of housing prices. Contrarily, the cost of
construction has not kept pace with these increases, which has
made it economically affordable to construct new buildings for
sale. This pattern remains the same in South Florida where there
continues to be an increased demand for housing, particularly in
Miami -Dade County.
There will be 310 residential units within the development. The
average sale price will be $700,000.
(d) A description of proposed energy conservation measures
shall be provided, including only those measures that are
proposed in addition to the minimum requirements in State
Energy Code.
Architecturally, the building envelope will be comprised of
insulated walls and roof. Tinted glass will be used throughout the
building. Electrically, all exterior and landscape lighting will be
controlled by means of time clocks and photocell switches. Energy
saving lamps, ballasts and fixtures are being considered at cores
and public spaces.
(e). Historic Buildings
There are no historic structures located on the property.
(f). Environmental Zone
The property is not located within an environmental preservation
district.