HomeMy WebLinkAboutPublic Works CommentsCITY OF MIAMI, FLORIDA • TO: FROM: INTER -OFFICE MEMORANDUM Roberto Lavernia Chief of Land Development Planning and Zoning Department Stephanie N. Griridell, P.E. Director Public Works Department DATE. SUBJECT: July 21, 2004 LSD Review - River Front East REFERENCES: ENCLOSURES: ZONING ZOO4 JUL d2 PM 3: 38 • • 1 have received the Large Scale Development plans for the River Front East project located at South Miami Avenue and S.W. 3 Street and have the following comments_ 1. Platting of land is required. A portion of the River Front East tract is currently unplatted. A sanitary sewer easement bisects the parcel and currently contains a 36-inch sanitary sewer interceptor pipe. A Florida Power and Light easement also bisects the parcel. In order to develop this project, the easements must be abandoned and the developer must arrange for the relocations of major utility facilities. 2. An agreement (covenant) between the City of Miami and the property owner is required for any non-standard installations in the public right of way (decorative sidewalk and pavement, landscaping, irrigation, decorative lighting). 3. Verify the requirements of the Miami -Dade County Public Works Department for access to South Miami Avenue. City of Miami driveway entrances, in compliance with A.D.A. standards, shall be required. The maximum driveway width is 40 feet unless approved by the Director of Public Works. 4. All transitions from the established street profile grade to the building flood elevation must be accomplished on private property. Stairs, ramps, retaining walls, etc. will not be permitted in the public right of way. 5. Dedication of the 25-foot corner radius at street intersection is required. 6. Standard parking stalls are 8 1 feet wide, 18 feet long and require 23 feet of back-up distance. 7. All stormwater must be retained on site including the driveways and plazas on private property adjacent to the public streets. All plazas and driveways must be graded or trench drams provided to prevent "sheet flow" form entering the right of way. 8. On sheet nos. A-303, A-305 and A-306, the proposed building support columns conflict with parking stalls and vehicle maneuvering. Also check sheet no. A-302, this sheet was missing from the large scale development review set. • • • Roberto Lavemia Chief of Land Development Planning and Zoning Department Page 2 July 21, 2004 9. On sheet no. A-201, the proposed building support columns conflict with the southerly service road and service alley. Building columns also conflict with visitor/retail parking and all three loading bay truck turning maneuvers. 10. On sheet no. A-102, the proposed building support columns conflict with parking stallsated within the ramp area. 11. On sheet no. LA-1.B, the sidewalk along N.W. 3 Street is approximately 5 feet wide and is too narrow to accommodate tree wells and meet A.D.A. minimum clear width requirements. The A.D.A. clearance requirements must be provided in the public right of way without requiring pedestrians to enter private property to go around the trees. The trees must be relocated back to private property to provide the proper clearance in the right of way. In addition to these comments, the following minimum right of way improvements will be required: Replace all broken and damaged sidewalk, curb and gutter adjacent to the project site. Tree grates will be required at all street tree wells adjacent to the site. Construct A.D.A. compliant handicap ramp on the southwest corner of the intersection of South Miami Avenue and S.W. 3 Street. Pavement restoration for all water and sewer extensions, existing damaged pavement and pavement damaged during construction, as determined by the City inspector, shall include milling and resurfacing of the full pavement width, curb to curb, along the entire length of the excavation and/or damaged pavement area. Milling and resurfacing of the full pavement width, curb to curb, along S.W. 3 Street from the west side of the Metrorail corridor to its intersection with South Miami Avenue shall be required. If you have any questions concerning these comments, please call Mr. Leonard Hel hers, Professional Engineer IV, at extension 1221. SNG/FM/Lf H/gc c: Lourdes Slazyk, Assistant Director, Planning & Zoning Department Stephanie N. Grindell, P.E., Director of Public Works