Loading...
HomeMy WebLinkAboutSite Utility StudySep-07-04 02:27P Robayna and Assoc. 305 823 1569 P_02 410 ROBNYNN AND ASSOCIATES INC. ENGINEERS - PLANNERS - SURVEYORS • • September 7.2004 City of Miami Re.: Lofts at Mayfair Mayor Use Special Permit Site Utility Study Civil Engineering Gentlemen: At the request of our client, The Royal Bay Group, we have prepared a summary of'our findings related to the water and sewer services for this project. SEWER SERVICE There is an existing 8" Gravity Sewer Line located on Florida Avenue. This Sewer line already have a 6" sewer lateral connecting the existing building. The proposed project will connect to this lateral and therefore to the existing system. We have discussed this connection with Miami -Dade Water and Sewer Department and it is acceptable. WATER SI:RVICF.S — DOMESTIC AND FIRE There is an existing 12" C.l. Water Main along Florida Avenue, an existing 8" C'.1. Water Main. along Virginia Street and an existing 6" C.I. Water Main along Oak Ave. all fronting this project. The intent is to connect this project to the existing 12- C.I. Water Main along Horida Ave. This concept have been discussed with Miami Dade County Water and Sewer Department and to pay Miami -Dade WASD a contribution of $8,487.30 for upgrading the Water Main along Virginia Street from 6" to 12" in diameter. As a point of'clarification, Phillip Torres. PE of Miami Dade WASD had written a memo on May 28.2004 stating that a number of additional improvements were to be required. Thereafter the City of Miami Fire Department did, on July 81h, 2004, a Fire Flow Test and Analysis for this project and issue a report indicating that sufficient fire flow existed to serve this project. Subsequently the report and additional information was submitted to the Development Infill Committee for their review and determination of'the required improvements. 'The requirements stated on Mr. Torres' Memo were replaced with the contribution to WASD as stated on the paragraph above. 5829 NV 158" Street. Miami 1.akes, Florida 33016* '1 c1,_(305)823-9316? 1 ux:(305)52 +-I5W) Sep--07-04 02:27P Robayna and Assoc. 305 823 1569 P.03 • • • Page 2 September 7, 2004 Respectfully Submitted ROBRYNfl AND ASSOCIATES INC. ENGINEERS - PLANNERS - SURVEYORS RO AYNA AND SSOCIATES. INC. Rafael.L.""Rohayna, PE President P'tatessional Engineer # 19453 State of Florida Cf: 04013711 5829 NW 158`3 Street. Miami Lakes, Florida 33016* L'ei.:(305)823-9316 r I'ax:(3{)5)823-1569 Sep-07-04 02:28P Robayna and Assoc. 305 823 1569 P.05 • • AVE • CONSERVE MiAMl-DARE WATER AND SEWER DEPARTMENT 3c .3U ia: �ii=.zti, Fiori a 33233-0316 • 3575 5.:eJe:ane Read • Tel: 305 - -boy-==%' • ra.,:30_ August 18, 2004 Miami, Florida LOFTS AT MAYFAIR Re: 3339 VIRGINIA ST The In -Fitt committee has reviewed your request and determined that the developer for the subject property will not be responsible for or required to install a 12" water main extension in VIRGINIA St. Please accept this letter as the Miami -Dade Water and Sewer Department's invoice for payment of in -fill contribution in the amount of $8,487.30 for the referenced property. This payment wilt be in lieu of a 12" water main extension along in VIRGINIA St. A breakdown of the above amount is as follows: Q:ty/Feet 282.91 Description,-:: In -Fill Contribution (12" WIM) 'Unit Price is Amount $30,O0 I $8,487.30 Total: $8,487.30 Please have a check in the amount of $8,487.30 made payable to Miami -Dade Water and Sewer Department and a copy of this letter when submitting payment. Please note that the cost for the verification form will be $150.00, which is not reflected in the contribution amount. To further, also note that New Business Unit will calculate connection charges when said verification form is issued. Should you have any questions regarding this matter, please do not hesitate to call me at (305) 669-7836. Sincerely yours, v Michael Vazquez Utilities Development In -Fill Development Committee Sep-07-04 02:28P Robayna and Assoc. 305 823 1569 P.06 • suty 22. 2no4 rA. DEVELOPMENT INFILL COMMITTEE Eggersz t PR0V LOCATION SKETCH AND SURVEY ® WATER ATLAS PAGE (PLOTTED ® SC4L ) El SEWER ATLAS PAGE (PLOTTED®SCGILE PUBLIC WORKS RESTORATION ►^t Atlas Page SCAN ID# ITEM # J-17 100395 FIRE FLOW REVIEW AERIAL (fYHIOME:GOT POINTS OF CONNECTION ZONING CODE SD-2 STING Property Location: 3339 VIRGINIA ST Peopllesoft Account (WTR ONLY / W&S) 1840818500 Type of unit: OFFICE - RETAIL. Tax Folio # 01-4121-034-0260 Sq.FtJNo.Of'kiis/Usage: 4" 6" Size of Muir,: 8" 12" 14,384 SF OFF 7,940 SF RETA 4" WM IN FLORIDA AVE, 6" WM IN OAK AVE, 8" WM IN VIRGINIA ST, Location: 12" WM IN FLORIDA AVE FOR LNFILL PER TOMAS GOICOURLA. - NEED TO CHECK GIVEN WATER B story: AND SEWER P.Q.C. Additional Sq. Ft./Units/Usage ® New Construction Size of main required: 12" pROPOSAI4 98 UNIT APT IfiCFREXACENTIVO NONE r t Demolished ❑ Renovations Additions Location: 12" WM IN VIRGINIA ST A..ND OAK AVE R & R Criteria: B2C3 =12" MAIN IS REQ. TO COVER THE REMAINDER FRONTAGE OF 1kLH., PROPERTY PREPARED BY: Michael Vazquez PREVIOUS FLOW 1,835 GPD PROPOSED FLOW 19,600 GPD i ' +`,CflM11 E/%1DATI ARE Approved By :. •: Approved By:. iproved By• . F'