HomeMy WebLinkAboutArticle II - Project Descriiption•
•
VILLA MAGNA
MAJOR USE SPECIAL PERMIT
PROJECT DESCRIPTION
ARTICLE 11,
Description
A. Zoning Ordinance No. 11000
1. Section 1304.2.1 Application Forms; supplementary materials
2. Section 1702.2.1 General Report
3. Section 1702.2.2 Major Use Special Permit Concept Plan
4. Section 1702.2.3 Development Impact Study
•
•
•
VILLA MAGNA
MAJOR USE SPECIAL PERMIT
PROJECT DESCRIPTION
Zoning Ordinance No. 11000
1. Section 1304,2.1 Application forms; supplementary materials
(a) Statement of ownership and control of the proposed development of
activity.
The Disclosure of Ownership and Ownership Affidavit are provided in
Article I.
(b) Statement describing in detail the character and intended use of the
development of activity.
VILLA MAGNA, the newest addition to the east Brickell neighborhood will
bring 1,208 upscale condominium residences and hotel apartments in two
attractive and uniquely designed 59-story towers.
VILLA MAGNA offers the energy, activity and feeling of being in the heart
of the business and cultural life while providing the area with an
architecturally exciting building and magnificent public Baywalk and
Pedestrian Plaza.
The development, located at 1201 Brickell Bay Drive, is contained within
the northern tract of a previously approved MUSP known as Bayshore
Palms. The proposed development consists of a parcel of land with a net
lot area of 108,726 square feet or 2.5 acres. The gross lot area is 161,486
square feet or 3.7 acres.
The Biscayne Bay creates the parcel's east boundary, and the parcel
faces directly onto Brickell Bay Drive to the west, NE 12th Street to the
north, and a landscaped Pedestrian Plaza and The Jade Condominium to
the south.
This Development will stand as an individual parcel with its own
improvements totally contained within its own site and in full compliance
with the law.
VILLA MAGNA will have at total of 1,208 upscale luxury condominium
units. There are two towers of 45 stories atop 12 parking levels, an
•
•
•
underground parking level and a plaza containing a restaurants and
ancillary neighborhood commercial and retail space.
The property will compliment the City's Brickell Avenue office and
residential districts and will contribute to the continuing development of
the downtown Miami residential market. Residents of VILLA MAGNA will
contribute expenditures to support retailing, restaurants and
entertainment, utilize the Peoplemover System and enliven downtown
after normal business hours. In general this project will increase the
quality of life in Downtown Miami.
The buildings recreational deck will be approximately 32,069 square feet
with a swimming pool, whirlpool spas, a Bar-B-Q area, and landscaped
areas for sunning, and relaxation. The common area will have a fitness
center with social rooms, exercise room, lockers and sanitary facilities with
an area of approximately 11,750 square feet.
The Property will also include a variety of street level retail, bayfront
restaurants and service amenities of more than 34,975 square feet, which
will enhance the project. The retail area will be available to both tenants
and the general public. The public as well as the residents of the project
will also enjoy a 107+ foot wide, attractively landscaped public pedestrian
promenade with several water features that will accesses a 50+ foot wide
public access Baywalk.
Drawings showing the architectural character and location of the intended
uses are included under Tab 6 of the Supporting Documents.
The approximate gross square footage for the property is as follows:
Gross Floor Area: 1,977,928 square feet excluding balconies.
(c) General location map, showing relation of the site or activity for
which special permit is sought to major streets, schools, existing
utilities, shopping areas, important physical features in and
adjoining the project or activity and the like.
The following exhibits are included with the Major Use Special Permit
Application and are located in front of this book.
(1) Location Map: Map of the surrounding street system indicating
the project location.
(2) Area Context Map: Map of the project area indicating buildings and
their functions that surround the site.
•
•
•
(3) Aerial: Aerial photograph of the surrounding area indicating the
project site.
(d) A site plan containing the title of the project and the names of the
project planner and developer, date, and north arrow and, based on
an exact survey of the property drawn to a scale of sufficient size to
show:
(1)
The Site plan is Sheet M-4 under Tab 6 of the Supporting Documents.
Boundaries of the project, any existing streets, building,
watercourses, easements and section lines;
The boundaries of the project and the location of existing streets and
easements are shown on the survey located under Tab 5 of the
Supporting Documents.
(2) Exact location of all buildings and structures;
(3)
The exact location of all existing buildings located on the Property is
shown on the survey located under Tab 5 of the Supporting Documents.
The location of the building to be constructed is shown on the Site Plan,
under Tab 6 of the Supporting Documents.
Access and traffic flow and how vehicular traffic will be
separated from pedestrian and other types of traffic;
A detailed analysis of the site access and traffic flow for the development
is provided in the Traffic Impact Analysis located under Tab 2 of the
Supporting Documents.
Vehicular access for residents, and visitors will occur on SE 12th Street,
rather than Brickell Bay Drive. Valet parking for visitors will be available at
the front doors of both residential towers. For residents of the Project,
ingress and egress ramps, through a security gate with card key access to
the upper level parking areas will occur off the driveway.
The underground garage parking level will be accessed by separate
ramps, which are also off of the driveway on SE 12th Street.
Service vehicles will access the fully enclosed Loading Docks off the
vehicle entry way at the central plaza. A total of four full size (4) Loading
Docks service the project.
4
•
•
•
(4) Off-street parking and off-street loading area;
Off-street parking for the building is provided within the 12 level pedestal -
parking garage. The off-street parking spaces are accessed by the ramps
located of of the driveway to the North Tower on SE 12th Street.
(5)
The building contains 1,474 parking spaces, including 28 Accessible
spaces.
The underground garage parking level will be accessed by separate
ramps, which are also off of the driveway on SE 12th Street.
Service vehicles will access the fully enclosed Loading Docks off the
vehicle entry way at the central plaza
Recreational facilities locations;
Recreational facilities are located on a recreational deck. which is on the
top level of the Tower's pedestal. The facilities are shown under Tab 6 of
the Supporting Documents.
(6) Screens and buffers;
Landscaping and buffer areas are indicated on the Landscape Plan,
under Tab 6 of the Supporting Documents.
(7) Refuse collections areas;
(8)
(e)
Electronic, containerized recycling compactor system located in the
service area will facilitate the waste collection. The waste removal and
recycling will be provided by a private company. The facility is shown on
the Ground Floor Plans under Tab 6 of the Supporting Documents.
Access to utilities and points of utility hookups.
Access and connections to site utilities are discussed in the Site Utility
Study located under Tab 3 of the Supporting Documents
Tabulations of total gross acreage in the project and the percentages
thereof proposed to be devoted to the permitted uses
and ground coverage.
VILLA MAGNA 161,486 gross square feet
3.7 gross acres
•
•
•
(1) The various permitted uses.
FAR
Allowed: 1,170,732 SF
Total 1,169,625 SF
FLOOR AREA CALCULATIONS
Residential 1,121,942 SF
Non -Residential 47,863 SF
Total 1,169,625 SF
(2) Ground coverage by structures.
BUILDING FOOTPRINT
Total Building Footprint 64,855 SF (60%)
(Ground Coverage)
(f) Tabulation showing:
(1) The derivation of numbers of off street parking and off street
loading spaces shown in (d) above:
There 1,120 total off street parking spaces provided as required by
Code. In addition there are 354 excess parking spaces provided in
the building. The off-street loading areas are shown on the ground
Floor Plans under Tab 6 of the Supporting Documents. The four
(4) loading bays required under the Code are provided according to
the plans. Four (4) bays are full size bays 107' X 25' with a
minimum clearance of fifteen (15') feet.
(2) Total project density in dwelling units per acre.
The Project contains 1,208 residential rental apartments and 2.5
net acres. 500 units per acre are allowed under the Code. The
residential project density per acre is:
500 Units x 2.5 Net Acres = 1,250 dwelling units permitted.
(g) If common facilities (such as recreation areas of structures,
6
•
•
•
private streets, common open space, etc.) are to be provided for the
development, statements as to how such common facilities are to be
provided and permanently maintained.
All common facilities will be maintained by either the Condominium
Associations or the Master Homeowners Association.
(h) Storm drainage and sanitary sewerage plans.
Storm drainage, water distribution, wastewater and solid waste generation
provisions are discussed in the Site Utility Study
located under Tab 3 of the Supporting Documents.
(i)
Architectural definitions for buildings in the development; exact
number of dwelling units, size, and types, together with typical floor
plans of each type.
APARTMENT DISTRIBUTION
North Tower 1-Bed 2-Bed Total
14th Floor 0 2 2 Units
15th-59th Floor 6 5 11 Units
Total Number of Apartments 497 Units
South Tower 1-Bed 2-Bed Total
14Th Floor 5 2 7 Units
15th-57th Floor 5 6 111 Units
Total Number of Apartments 502 Units
Apartment Hotel 209 Units
Total Number of Units 1,208 Units
The building details pertaining to the number of dwelling
units, sizes and types, together with typical floor plans are
included under Tab 6 of the Supporting Documents. The Retail
Areas are shown under Tab 6 of the Supporting Documents.
(j) Plans for signs, if any.
A building identification sign will be located on the face of each of the two
towers, and facing Brickell Bay Drive.
Retail name signs will be located on the storefronts. All signs will be sized
7
•
•
•
and styled in compliance with the required regulations. A
Retail/Commercial Tenant Design Booklet is planned.
(k) Landscaping plan, including types, sizes and locations of vegetation
and decorative shrubbery, and showing provisions for irrigation and
future maintenance.
(I)
The Landscaping Plan located on Sheet L-100 through L-101
under Tab 6 of the Supporting Documents, specify the plant types, sizes
and locations, as well as indications that all planted
areas will be fully irrigated and maintained by the Condominium
Associations or Master Association.
Plans for recreation facilities, if any, including location and general
description of buildings for such use.
The property has a recreational deck where the recreational facilities are
provided. The deck will have swimming
pools, whirlpool spas, a fitness center with exercise room,
lockers and sanitary facilities. Outdoor recreation deck areas for lounging
and sunning, a multi -purpose meeting/ party rooms, Bar-B-Q area, and a
refreshment Bar is also located on the recreation deck.
Such additional data, maps, plans, or statements as may be
required for the particular use or activity involved.
The Drawings submitted with this Application are located under
Tab 6 of the Supporting Documents.
(n) Such additional data as the applicant may believe is pertinent to the
proper consideration of the site and development plan.
Elevations and sections depicting the architectural character of the Tower
are included under Tab 6 of the Supporting Documents. Computer
generated renderings of the project are also included under Tab 6,
2. Section 1702.2.1 General Report.
(1) Property ownership or ownership's and beneficial interest within the
boundaries of the area proposed for Major Use Special
Permit.
Statement of Ownership and beneficial interest within the boundaries of
the area proposed for Major Use Special Permit are provided in Article 1.B
& C.
8
•
•
•
(2) The nature of the unified interest or control.
(3)
The nature of unified interest or control is indicated in Article 1.
Survey of the proposed area showing property Tines and
ownership.
A copy of the survey of the Property is included under Tab 5 of the
Supporting Documents.
(4) Map of existing features, including streets, alleys, easements,
utilities lines, existing land use, general topography, and physical
features.
(5)
The existing site features and utility lines are shown on the survey of
Property located under Tab 5 and the Site Utility Study located under Tab
3 of the Supporting Documents. The following exhibits are also
included with the Major Use Special Permit Application:
(a)
Location Map: Map of the surrounding street system indicating the
project location.
(b) Aerial: Aerial photograph of the surrounding area indicating the
project site.
Materials to demonstrate the relationship of the elements listed in (4)
proceeding to surrounding area characteristics.
The Drawings Submitted with this Application are located under Tab 6 of
the Supporting Documents.
(6) Existing zoning and adopted comprehensive plan designations for
the area on and around the lands proposed for Major Use Special
Permit.
The existing zoning designation for the Property pursuant to City of Miami
Ordinance No. 11000, as Amended is SD-5. The Zoning Atlas Map on
plate 37 indicates the existing and surrounding zoning. The
comprehensive plan future land use designation for the Property is
"Restricted Commercial". The zoning and the comprehensive plan
designation are consistent with one another.
3. Section 1702.2.2 Major Use Special Permit Concept Plan.
a. Relationships of the concept plan to surrounding existing and
9
•
•
•
proposed future uses. Activities, systems and facilities
(transportation, recreation, view corridors, pedestrian systems,
services systems and similar uses).
Article 11 contains a written narrative of the Project outlining proposed
uses, activities and architectural character. This narrative also contains
descriptions of the Project's relationship to traffic, pedestrian movements,
and transportation access. Maps are provided to indicate the Project's
relationship to surrounding streets, land uses and functions. Building
elevations, sections and perspectives showing the proposed materials,
vertical profile and height, and orientation to streets is included in the
Drawings Submitted with this Application. The list of Drawings Submitted
is found under Tab 6 of the Supporting Documents.
b. Existing zoning and adopted comprehensive plan principles and
designations.
The Project conforms to the SD-5 zoning for this Property. The
comprehensive plan future land use designation conforms with the
land use designation currently in effect for this Property.
4. Section 1702.2.3 Developmental impact Study.
a. A traffic analysis shall be submitted for an area within approximately
1/4 mile of the site, or an area including the major intersections to be
impacted by the site, whichever is larger.
The Traffic Impact Analysis is included under Tab 2 of the Supporting
Documents.
b. Economic impact data shall be provided, including estimates for
construction costs, construction employment, and permanent
employment.
The Economic Impact Study is included under Tab 4 of the Supporting
Documents.
G. A housing impact assessment.
The Project will contain 497 Residential condominium units in the North
Tower. There are 502 condominium units in the South Tower and an
additional 209 Hotel apartments located in the Pedestal, for a total of
1,208 units. The sales prices are projected to range from $150,000 to
$750,000.
10
•
•
•
d. A description of proposed energy conservation measures shall be
provided, including only those measures that are proposed in
addition to the minimum requirements in State Energy Code.
Architecturally, the building envelope will be comprised of insulated walls
and roof. Heat resistant, tinted glass will be used throughout the building.
Extensive use of wall shading by means of balconies will be implemented.
Electrically, all exterior and landscape lighting will be controlled by means
of time clocks and photocell switches. Energy saving lamps. ballast's and
fixtures are being considered in all common areas.
Energy Star Appliances including water and energy efficient washers
and dryers will be installed.
e. Historic buildings.
The site is vacant and efficiently utilized as a parking lot, there are no
historic structures located on the Property.
f. Environmental zone.
The Property is not located within an environmental preservation
district.