Loading...
HomeMy WebLinkAboutSite Utility Study• Site Utility Study COLUMBUS RESIDENTIAL TOWER Submitted to: TRG FLAGLER BISCAYNE HOLDINGS, LTD 1688 Meridian Avenue, Suite 200 Miami Beach, Florida 33139 • Prepared by: PBS&J 2001 N.W. 107th Avenue Miami, Florida 33172 July 2004 • • • • TABLE OF CONTENTS Page 1, General .. 1 2. Storm Drainage System 2 3. Water Distribution System 3 4. Sewer Collection System 4 5. Other Utilities 5 EXHIBITS: "A" Storm Drainage Well Calculations "B" Water/Wastewater Demand Calculation "C" Miami -Dade Water & Sewer Department Letter of Availability Application "D" Sewer Atlas Page "E" Water Atlas Page "F" Utility Letter: FPL, Bellsouth, Miami TCI, Peoples Gas • • • COLUMBUS RESIDENTIAL TOWER SITE UTILITY STUDY . GENERAL A. Project Location and Size: The proposed development consists of a residential tower and parking garage with some retail and restaurants. The project is located at Lots 1 through 7, inclusive, Block 119N, A.L. Knowlton's Map of Miami, Plat Book B, page 41 Miami -Dade County, Florida, in Section 6, Township 54 South, and Range 42 East. The site is bounded by Biscayne Boulevard to the east, NE 1st Street to the north, NE 3rd Avenue to the west, and East Flagler Street to the south, and consists of 1.2978 acres more or less. The site is currently occupied by a shopping center that consists of four one story concrete block buildings. These existing buildings will be demolished to accommodate the new Columbus Residential Tower. B. The development program for the project is as follows: Apartments: 517 Retail Shops : 5,727 GSF Full Service Restaurant: 500 seats Health Club/ Spa/Gym 17,700 SF PBS&J July 2004 • • • 2. STORM DRAINAGE SYSTEM A. Existing Storm Drainage System The City of Miami presently maintains the roadway drainage system around the site. The storm water runoff from the existing roadway is directed and conveyed into the City drainage system. The existing site is occupied by four one story buildings. A brick sidewalk abuts Biscayne Boulevard, and concrete sidewalks along the remaining three sides. The site has an asphalt paved area in between the buildings with catch basins, and does not appear to contribute any significant amount of storm water run-off into the public roadway system. B. Proposed On -Site Storm Drainage System Storm water discharge from the proposed development area will consist mainly of building roofs, building walls, driveways and landscape area run-off. After development the site is assumed to be approximately 95% impervious. The primary drainage system for the project will consist of drainage wells. The rainfall runoff will be conveyed by the series of roof drains, rain -water leaders and plumbing pipes to the drainage wells. It is anticipated that an Environmental Resource Permit (ERP) will not be required for stormwater runoff, as the site area is less than two acres. However, it is assumed that for the site drainage permit the 5-year, 25-year and 100-year, 3-day storm events are to be considered. The total contributing area for stormwater will consist of the site area, and 30% of two sides of building wall area which are exposed to the rain at any given time. This criteria would be used for determining the number of wells. Based on data provided by local experienced well drilling companies, a 600 to 750 gpm per foot head of discharge rate can be expected, for the wells. C. Storm Drainage Wells: Based on the above criteria and assumptions, four (4) drainage wells would be required for the site, depending on the actual yields obtained during the well drilling operations. For storm drainage calculations refer to the attached Exhibit 'A'. PBS&J Page 2 July 2004 • • • 3. WATER DISTRIBUTION A. Existing Water System Facilities: The Miami -Dade Water and Sewer Department (MD-WASD) owns and operates the following water mains in the vicinity of the project. Location Between Water Main(s) Diameter Biscayne BI NE lst St to East Flagler 24", 12" and 6" NE 1st St NW 3rd Ave to Biscayne BI 20" NE 3 rd Ave NE lst St to East Flagler 12" and 4" East Flagler NE 3rd Ave to Biscayne BI 6" The project sites are surrounded by water mains of 12" and larger diameter. At locations of two water mains on the same street, WASD will require connection to the larger diameter water main. The water extensions if required would be determined by MD-WASD. A fire hydrant flow test is recommended. B. Water Demand The anticipated water demand for the project is 134,882 gpd. The development plan with its water demands is shown in Exhibit `B'. C. Required Water System Improvements: An application has been made to the Miami -Dade Water and Sewer Department for the water and sewer availability letter. This would outline the points of connection for the water and sewer. Any water main extensions constructed by the developer as a requirement of this project would have to be conveyed to MD-WASD. PBS&J Page 3 July 2004 • • 4. WASTEWATER COLLECTION A. Existing Sanitary Sewer Collection System: The Miami -Dade Water and Sewer Department (MD-WASD) owns and operates the following gravity sewer collection mains in the vicinity of the project. Location Between Sewer Main(s) Diameter Biscayne BI NE 1st St to East Flagler 16" and 10" NE lst St NE 3rd Ave to Biscayne BI 12" NE3rdAv NE 1st St to East Flagler 8" East Flagler NE 3rd Ave to Biscayne BI 16" The wastewater collection system flows by gravity and connects to the regional WASD pump station No 2. B. Projected Waste Water Demand: Average Daily Flow (from Table 1) 134,882 gpd Average Flow (gallons per minute) 94 gpm Projected Peak Flow ( 3.5 peak factor) 328 gpm C. MD-WASD Availability letter: An application has been made to the Miami -Dade Water and Sewer Department for the sewer availability letter, for the project. PBS&J Page 4 July 2004 • • • 5. OTHER UTILITIES FPL The electric company FPL provides service to the downtown Miami area at the site location. BELLSOUTH The telephone service to the site is provided by Bellsouth. MIAM1 TCI The cable provider for the site is Miami TCI. PEOPLES GAS The gas company providing service to the site is Peoples Gas. PBS&J Page 5 July 2004 • EXHIBIT "A" STORM DRAINAGE WELL CALCULATIONS COLUMBUS RESIDENTIAL TOWER • • PROJECT NAME: COLUMBUS RESIDENTIAL TOWER DRAINAGE AREA: ENTIRE SITE SITE DATA: SITE DATA= 1.30 CONTRIBUTING BUILDING WALL AREA= 1.37 TOTAL CONTRIBUTING AREA= 2.67 REQUIRED VOLUME FOR 90 SEC. DETENTION TIME: DISCHARGED RATE (EACH WELL)= REQUIRED DETENTION VOLUME= 2000 gat/min 3000 gal/min 402 cu ft TANK LENGTH= 14 TANK WIDTH= 7 TANK BOTTOM ELEV= 0 TOP OF WEIR ELEV= 3 STORAGE DEPTH= 4.1 DETENTION VOLUME PROVIDED= 402 cu ft • • • • • PROJECT NAME: COLUMBUS RESIDENTIAL TOWER DATE: 07-15-04 DRAINAGE AREA: ENTIRE SITE BUILDING WALL AREA CALCULATIONS: THIS AREA WILL INCLUDE THE TWO SIDES OF THE PROPOSED BUILDING WHICH ARE EXPOSED TO THE RAIN AT ANYONE TIME. BUILDING PEDESTAL: THIS A 9 STORY PARKING GARAGE WALL LENGTH: STRUCTURE HEIGHT: WALL AREA: OFFICE TOWER: WALL LENGTH: STRUCTURE HEIGHT: WALL AREA: TOTAL EXPOSED WALL AREA: 437 FT 95 FT 41,515 SF 306 FT 448 FT 137,088 SF 178,603 SF THE CONTRIBUTING AREA IS ONE THIRD OF THE EXPOSED WALL AREA CONTRIBUTING AREA: 59,534 SF 1.37 ACRES • • • PROJECT NAME: COLUMBUS RESIDENTIAL TOWER DATE: 07-15-04 DRAINAGE AREA: ENTIRE SITE DRAINAGE WELL DATA: WELL DIAMETER= WELL DISCHARGE RATE PER FT OF HEAD= AVAILABLE HEAD= DISCHARGE RATE PER WELL= 24 INCHES 750 GPM 2.67 FT 2,000 GPM DRAINAGE CALCULATIONS PEAK RUNOFF TOTAL AREA 1.30 (SITE) IMPERVIOUS (95%) 2.54 PERVIOUS (5%) 0.13AC WEIGHTED RUNOFF COEFFICIENT C= (2.54x0.90+0.13x0.25)/2.67=0.87 DESIGN STORM 5 YEARS TIME OF CONCENTRATION 10 MINUTES RAINFALL INTENSITY 6.1 IN/HR PEAK RUNOFF (Q=CIA) Q=0.87x6.1 x2.67=14.17 CFS ASSUME EACH 24" DIAMETER WELL FLOWS AT 2000 GPM=4.45 CFS NUMBER OF WELLS REQUIRED 14.17/4.45=3.2 WELLS TOTAL NUMBER OF WELLS REQUIRED 4 WELLS EXHIBIT B COLUMBUS RESIDENTIAL TOWER PROJECTED WATER / WASTEWATER DEMAND ' p `� NUMBER DEVELOPMENT PROGRAM UNIT FLOW QUANTITY TOTAL FLOW TOTAL EACH sat 0 A APARTMENT UNITS 200 517 103400 SHOPPING CENTER • DRY USE 5727 SF 0.05 5727 286, 35 0 0 FULL SERVICE RESTAURANT • 500 SEATS 50 500 25,000 HEALTH CLUB i SPA 1 GYM .. 17,700 SF 0.35 17700 6195 TOTAL 134881.35 134881.35 134881.35" TOTAL • • 2 7/16/2004 EXHIBIT 'C' 10/01/03 14:29 FAX 3056097699 ailiWiteCONaale.41 I—DWASD NEW BUSINESS ML4MI-DADE WATER AND SEWER DEPARTMENT NEW BUSINESS SECi1ON. P.U. Box 330316, Mland, Florida 33233-0316 + Tel: 305-669.7701 LETTER OF AVAILABILITY REQUEST FORM WATER SERVICE AREA ONLY SEWER SERVICE AREA ONLY WATER AND SEWER SERVICE AREA (If the Project Is in a.water service area ONLY) (if the Project Is in a sewer service area ONLY) (if the Project is in a water and sewer service area) $ 50.00 $50 00 $i00,00 1. Please make check payable to: Miami -Dade Water and Sewer Department. 2. A CERTIFIED boundary survey of the property is required An*d Proof of Zoning from Municipality(faxed requests are not acceptable) 3. Points of connection can ONLY be provided in a Letter of Availability. i io01 :F;."IiG'�""tf nrrK. t..- '��"+'�,'�,Y`' Uf3i r`"'{"§�.s.:�-Pr�'rr.���-�,� ���s�`�a Name: • Address: Joyce M. Bronson TRG-Flagler Biscayne Holdings, Ltd. 1688 Meridian Avenue, Suite 200 City: Miami Beach State: FI Zip: 33139 Work Phone: Cell Phone: 305-674-8310 Beeper: Phone2: -�7 was Address of proposed or existing property: Folio Number R Zoning (Proposed or Existing): Type of Units to be Constructed: 48-56 North Biscayne Blvd., Miami, FI 01-0111-190-1011 Residential Building eae smote femaw Aeeidenem Apartrosailt Magna Ono Maks Restaurant,. Etc . Usage: (Square footage, no. of seats /Units) . Apartments-517 units, Shopping Center dry use-5727 SF, Full Service Restaurant-500 seats, Health/SoaLGym-17.70Q SF Comments: PROCESSING TIME WILL BE APPROXIMATELY 3 TO 6 WEEKS FROM SUBMITAL. Additional processing time maybe required based on the project Date: location, sire, pumper station, cornpte dtY and incomplete information. .. 11124 • VT s Y $ T • r a 1•41.44.4•114.. a•$ • intaatit • 41* twat • • • • 41/111111 • •"2 : •. 1 • • •- .• i• r i'••• Y' t o 1 • • •• k r ►.• a . *:-•d. :- i'".- i...a ,.t. k:,:ar •'„„; r�3ti• ..y,♦ a -. . ,';Fri •1.!3L..•.:. •'• }} .i•• •1 -•• . • t..=•! •.5 i •, `Y•„x "A. .?:• ., .:• ...•a'4 •..a- ••.: .+,_.. .�' •sw • � '• ...; !. a.: • I•• • r.G'y',.r...•.e.'.y•i.i. h"r-i•-•.• •ret•`44 ,.•,.. ..• .•y.ya • •k1- .3•r ±..i•t.,r...[ �i• ...'• -as.-- .rw..a-•, a,.....__r�a-.•ys. tr.:•�•"." Y.f `.r.ry .1." -- - .. •...w. .1...w.......+7••j..vA•r:s"•• •l..; a • i••_ w• I -. • S • 1 • d • :. gr. • .- ..... ^_'rr EXHIBIT D • //..{{ Y�� My•T. yWM ON • r . w.. 1 • f. w. , •.•.. , • • • 1stqal �'� • PBS • July 12, 2004 Kareem Brantley FP&L Central Distribution & Maintenance Department 122 S.W. 3'd Street Miami, Florida 33130 Re: Columbus Residential Tower Project Address: 48-56 North Biscayne Blvd. Dear Mr. Brantley: PBS&J is in the process of designing improvements to the above referenced project. The development program consists of 525 Residential Units and 20,000 S.F. Retail. Please advise of the adequacy and availability of FPL service to the project. Also, provide "As -Built" or Record Drawings of your company's facilities located along the roadways as highlighted in the attached Location Map, including any service line and easements within the project site. Site Information: Site Address: 48-56 North Biscayne Blvd. Development Program: 525 Residential Units, 20,000 S.F. Retail Zoning: CBD-Central Business District -City of Miami If you have any questions, please call me at 305-514-3431, Fax No. 305-599-0448, E-mail: eortiz@pbsj.com. ery ly yours, tLy... rain Ortiz Civil Engineering Department Cc: C. Coonnese (TRG) 2001 Northwest 107th Avenue, Miami, Florida 33172-2507 • Telephone (305) 592-7275 • www.pbsj.com • PBSJ • • July 12, 2004 Janet Valencia Bellsouth 7325 S.W. 48th Street Miami, Florida 33155 Re: Columbus Residential Tower Project Address: 48-56 North Biscayne Blvd. Dear Ms. Valencia: PBS&J is in the process of designing improvements to the above referenced project. The development program consists of 525 Residential Units and 20,000 S.F. Retail. Please advise of the adequacy and availability of FPL service to the project. Also, provide "As -Built" or Record Drawings of your company's facilities located along the roadways as highlighted in the attached Location Map, including any service line and easements within the project site. Site Information: Site Address: 48-56 North Biscayne Blvd. Development Program: 525 Residential Units, 20,000 S.F. Retail Zoning: CBD-Central Business District -City of Miami If you have any questions, please call me at 305-514-3431, Fax No. 305-599-0448, E-mail: eortiz@pbsj.com. V yours, `n Ortiz ivil Engineering Department Cc: C. Coonnese (TRG) 2001 Northwest 107th Avenue, Miami, Florida 33172-2507 • Telephone (305) 592-7275 • www.pbsj.com • PLISI • • July 12, 2004 Mike Slater Miami TCI 1306 N.W. 7th Avenue Miami, Florida 33136 Re: Columbus Residential Tower Project Address: 48-56 North Biscayne Blvd. Dear Mr. Slater: PBS&J is in the process of designing improvements to the above referenced project. The development program consists of 525 Residential Units and 20,000 S.F. Retail. Please advise of the adequacy and availability of FPL service to the project. Also, provide "As -Built" or Record Drawings of your company's facilities located along the roadways as highlighted in the attached Location Map, including any service line and easements within the project site. Site Information: Site Address: 48-56 North Biscayne Blvd. Development Program: 525 Residential Units, 20,000 S.F. Retail Zoning: CBD-Central Business District -City of Miami If you have any questions, please call me at 305-514-3431, Fax No. 305-599-0448, E-mail: eortiz@pbsj.com. fy yours rtiz ineering Department Cc: C. Coonnese {'FRG) 2001 Northwest 1071t Avenue, Miami, Fbrida 33172-2507 • Telephone (305) 592-7275 • www.pbsj.com • pirti • • July 12, 2004 Angel Guant Peoples Gas 15779 West Dixie Highway North Miami, Florida 33162 Re: Columbus Residential Tower Project Address: 48-56 North Biscayne Blvd. Dear Mr. Guant: PBS&J is in the process of designing improvements to the above referenced project. The development program consists of 525 Residential Units and 20,000 S.P. Retail. Please advise of the adequacy and availability of FPL service to the project. Also, provide "As -Built" or Record Drawings of your company's facilities located along the roadways as highlighted in the attached Location Map, including any service line and easements within the project site. Site Information: Site Address: 48-56 North Biscayne Blvd. Development Program: 525 Residential Units, 20,000 S.F. Retail Zoning: CBD-Central Business District -City of Miami If you have any questions, please call me at 305-514-3431, Fax No. 305-599-0448, E-mail: eortiz@pbsj.com. Very frain Ortiz Civil Engineering Department Cc: C. Coonnese (TRG) 2001 Northwest 107lb Avenue, Miami, Florida 33172-2507 • Telephone j305) 592-7275 • www.pbsj.com