HomeMy WebLinkAboutArticle II - Project DescriptionGALLERY ART
MAJOR USE SPECIAL PERMIT
PROJECT DESCRIPTION
ARTICLE II.
Project Description
A. Zoning Ordinance No. 11000
1. Section 1304.2.1 Application forms; supplementary
materials
2. Section 1702.2.1 General Report
3. Section 1702.2.2 Major Use Special Permit Concept Plan
4. Section 1702.2.3 Development Impact Study
•
•
•
•
•
GALLERY ART CONDOMINIUM
MAJOR USE SPECIAL PERMIT
1. Section 1304.1.1 Application forms; supplementary materials
(a) Statements of ownership and control of the proposed development
of activity.
The Disclosure of Ownership and Ownership Affidavit are provided in
Article I.
(b) Statement describing in detail the character and intended use of
the development or activity.
"GALLERY ART CONDOMINIUM" will be a 17 story residential
building with 164 units, 7 office/live units, and 208 parking spaces. The
project is located on Biscayne Blvd. between Northeast 24th & Northeast
25th Street, Miami, Florida. The development consists of a parcel with a
net lot area of 55,658 square feet (1.28 acres). The gross lot area is
68,279 square feet (1.56 acres). The property fronts Northeast 24th
Street on the South, and Northeast 25th street on the North. The zoning
designation for the property is R-4/C-1 /SD-20 Overlay.
The proposed building will contain 164 residential units, 7 office/live
units and 208 parking spaces. The building provides a continuous liner
of residential units along both Northeast 24th and Northeast 25th streets
for the entire 4 levels height of the garage. The 5th level will contain
active amenities such as a pool, club room and exercise room.
The main entrance to the project is through a beautifully landscaped
porte-cochere off Northeast 24th Street with water features and textured
colored concrete floors. Main entrance to the parking garage will also
be from Northeast 24th Street, and there will be a service entrance to
the parking garage where the required loading spaces are located
through Northeast 25th street. Building residents and guests will be able
to choose between valet parking or self parking.
The ground floor will contain the lobby, parking, office/live and
townhouses with entrances along the streets as well as access from the
lobby. The 2nd through 4th floor will contain townhouse units, office/live
units, and parking with some storage designated areas. The 5th level
will contain (4) residential units, the gym, dub room, pool deck, spa,
planters, bathrooms, and the administration office. The 6th through 17th
levels will have all residential units.
The Architects while designing the building were very sensitive to the
existing historically designated building located to the west of the project
on Biscayne Blvd, and therefore designed the building to step back on
the west side allowing a greater feeling of openness to the pedestrian
and automobiles for the main entrance to the building.
•
•
•
The Architects also, created an artistic and creative solution to conceal
the garage on the West and East elevations by the use of laminated
colored glass insets which will be light during the night.
Also, the base and tower portions of the building are provided with a
great amount of transparency through the use of windows, balconies
and terraces.
(c) General location map, showing relation of the site or activity for
which special permit is sought to major streets, schools, existing
utilities, shopping areas, important physical features in and
adjoining the project or activity and the like.
The following exhibits are included with the Major Use Special Permit
Application:
(1) Aerial: Aerial photograph of the surrounding area indicating the
project site.
(2) Area Context Map/Site Aerial: Map of the project area
indicating buildings and their functions that surround the site
including projects under construction in the area.
(3) Location Map: Map of the surrounding street system indicating
the project location.
(d) A site plan containing the title of the project and the names of the
project planner and developer, date, and north arrow and, based on
an exact survey of the property drawn to a scale of sufficient size
to show:
The general information requested is shown on the Level 1-Ground
Floor plan, provided under Tab 6 of the Supporting Documents. The
site plan includes the following:
(1) Boundaries of the project, any existing streets, buildings,
watercourses, easements and section lines;
The boundaries of the project and the location of existing
streets and easements are shown on the Survey located
under Tab 5 of the Supporting Documents.
(2) Exact location of all buildings and structures;
The exact location of all existing buildings located on the
property is shown on the Boundary Survey under Tab 5. The
location of the building to be constructed is shown on the Level
1-Ground Floor Plan, located under Tab 6 of the Supporting
Documents.
•
•
•
(3) Access and traffic flow and how vehicular traffic will be
separated from pedestrian and other types of traffic;
Vehicular access for the project is from Northeast 24th Street.
Access to the parking garage is located at the lobby. The
service drive for the project, as well as the loading areas are
located on Northeast 25th Street.
A detailed analysis of the site access and traffic flow is
provided in the Traffic Impact Analysis located under Tab 2 of
the Supporting Documents.
(4) Offstreet parking and offstreet loading areas;
The offstreet parking facility will include a 4 level parking
structure with 208 parking spaces. The garage is shown on
Level 1-Ground Floor Plan through Level 4-Parking Plans,
provided under Tab 6 of the Supporting Documents.
The Zoning Ordinance requires three (3) loading bays. There
will be two (_2_) loading bay 12 ft. x 35 ft. and one (1) berth 10
feet x 20 feet. The clearance for all loading bays is 24 feet.
Service areas are shown on the Level 1-Ground Floor Plan,
under Tab 6 of the Supporting Documents.
(5) Recreational facilities locations;
The parking roof- level 5th, will serve as a recreation deck for
the development and will include indoor and outdoor amenities.
It will include indoor recreational facilities such as lounge and
Gym, lockers, bathrooms, showers, and a Club Room. Exterior
facilities will include a swimming pool with a pool deck, spa,
benches, cabanas, ottomans and planters.
These facilities are shown on the Level 5-Poold Deck Floor
Plan located under Tab 6 of the Supporting Documents.
(6) Screens and buffers;
Landscaped areas are indicated on the Landscape Plans,
Sheet LP-1, LP-2, located under Tab 6 of the Supporting
Documents.
(7) Refuse collections areas;
Waste collection will be provided by a containerized compactor
system located within the service area. These facilities are
shown on the Level 1-Ground Floor Plan, located under Tab 6
of the Supporting Documents.
•
o
•
(8) Access to utilities and points of utilities hookups.
Access and connections to site utilities are discussed in the
Site Utility Study located under Tab 3 of the Supporting
Documents.
(e) Tabulations of total gross acreage in the project and the
percentages thereof proposed to be devoted to;
(1) The various permitted uses:
Residential (R-4) Sq. Ft. = 176,160 S.F.
Commercial (C-1) Sq. Ft. = 15,604.1 S.F.
(2) Ground coverage by structures:
Building Footprint = 34,104 S.F.
Ground coverage by the structures is 49.9% of the total gross lot area.
(f) Tabulation showing the following:
(1) The derivation of numbers of offstreet parking and
offstreet loading spaces shown in (d) above;
The total number of offstreet parking spaces required is 199 spaces and
the total number of spaces provided is 208 spaces. Derivation of the
number of offstreet parking is shown under the Project Fact Sheet,
within the Project Summary, located under Tab 6.
(2) Total project density in dwelling units per acre.
As per R-4 the maximum project density is 150 units per acre.
The designated site is 1.28 acres, which allows for the
construction of 192 units. This project will provide 171 units
(164 Residential Units + 7 Office/Live Units).
(g) If common facilities (such as recreation areas of structures, private
streets, common open space, etc.) are to be provided for the
development, statements as to how such common facilities are to
be provided and permanently maintained.
All common facilities to be provided will include the swimming pool, spa,
club room, gym, bathrooms. The common areas will be maintained by
the Owner and ultimately by the condominium associations.
•
•
•
(h) Storm drainage and sanitary sewerage plans.
Storm drainage, water distribution, waste water and solid waste
generation provisions are discussed in the Site Utility Study located
under Tab 3 of the Supporting Documents.
(I) Architectural definitions for buildings in the development; exact
number of dwelling units, sizes, and types, together with typical
floor plans of each type.
Detailed information and breakdown of square footage of all uses are
found under Unit Areas calculations, included under Tab 6 of the
Supporting Documents. Typical floor plans for residential units are
shown on the Typical Residential Floor Plans Level 6-17. All drawings
are located under Tab 6 of the Supporting Documents.
(j) Plans for signs, if any.
The project will obtain signage approval at a later date.
(k) Landscaping plan, including types, sizes and locations of
vegetation and decorative shrubbery, and showing provisions for
irrigation and future maintenance.
The landscape plans showing vegetation are found on LP-1, and LP-2
Landscape Plans. All landscape plans are located under Tab 6 of the
Supporting Documents.
(I) Plans for recreation facilities, if any, including location and general
description of buildings for such use.
The 5th Level will contain a swimming pool, spa, a recreation deck, Club
Room, Bathrooms, and a Gym. The recreational facilities for the
building are shown located on the Level 5-Pool Deck Floor plan.
(m) Such additional data, maps, plans, or statements as may be
required for the particular use or activity involved.
The details of the spaces and calculations used to compute the Floor
Area Ratio (FAR) are shown on the Project Data Sheet, provided under
Tab 6 of the Supporting Documents.
(n) Such additional data as the applicant may believe is pertinent to
the proper consideration of the site and development plan.
Elevations depicting the architectural character of the building and the
interaction with the historic preservation building to the West side are
shown on the Buildings Elevations North, East, and South & West
Elevations. All elevations are located under Tab 6 of the Supporting
Documents.
•
•
2. Section 1702.2.1 General Report.
(1) Property ownership and beneficial interest within the boundaries of
the area proposed for Major Use Special Permit.
Statement of Ownership and beneficial interest within the boundaries of
the area proposed for Major Use Special Permit are provided in Article I.
(2) The nature of the unified interest or control.
The nature of unified interest or control is indicated in Article I.
(3) Survey of the proposed area showing property lines and
ownership.
A copy of the Surveys is included under Tab 5 of the Supporting
Documents.
(4) Map of existing features, including streets, alleys, easements,
utilities lines, existing land use, general topography, and physical
features.
(5)
The existing site features and utility lines are shown on the Boundary
Survey of the property located under Tab 5. The site features and the
utilities are also described in the Site Utility Study, located under Tab 3
of the Supporting Documents.
Materials to demonstrate the relationship of the elements listed in
(4) preceding to surrounding area characteristics.
The drawings submitted with this Application are located under Tab 6 of
the Supporting Documents.
(6) Existing zoning and adopted comprehensive plan designations for
the area on and around the lands proposed for Major Use Special
Permit.
The existing zoning designation for the property pursuant to City of
Miami Ordinance No. 11000 and Plat Book 30, at Page 12 of the Public
Records of Miami -Dade County, Florida. (which is located in Article I),
indicates the existing and surrounding zoning. The zoning designations
for the property are R-41C-1ISD20 Overlay. The Comprehensive Plan
Future Land Use designation for the property is Residential High
Density. The zoning and the comprehensive plan designations are
consistent with one another.
•
•
o
3. Section 1702.2.2 Major Use Special Permit Concept Plan.
a. Relationships of the concept plan to surrounding existing and
proposed future uses, activities, systems, and facilities
(transportation, recreation, view corridors, pedestrian systems,
service systems and similar uses.
Article II contains a written narrative of this project outlining proposed
uses, activities and architectural character. This narrative also contains
descriptions of the project's relationship to traffic, pedestrian
movements, and transportation access. Building elevations, sections
and perspectives showing the proposed materials, vertical profile and
height, and orientation to streets are included in the drawings submitted
with this Application. The list of drawings submitted is found under Tab
6 of the Supporting Documents.
b. Existing zoning and adopted comprehensive plan principles and
designations.
The project conforms with the R-4/C-1/SD-20 overlay zoning district
designation for the property. The comprehensive plan future land use
designation conforms with the land use designation currently in effect for
the property.
4. Section 1702.2.3 Developmental Impact Study.
(a) A traffic analysis shall be submitted for an area within
approximately 114 mile of the site, or an area including the major
intersections to be impacted by the site, whichever is larger.
The Traffic Impact Analysis is included under Tab 2 of the Supporting
Documents.
(b) Economic impact data shall be provided, including estimates for
construction costs, construction employment, and permanent
employment and shall demonstrate that the proposed development
is favorable to the economy, public services, environment and
housing supply of the City.
The Economic Impact Study is included under Tab 4 of the Supporting
Documents.
(c) A housing impact assessment.
There will be 164 residential units within the development. And 7
office/live units. The average sale price will be $
(d) A description of proposed energy conservation measures shall be
provided, including only those measures that are proposed in
addition to the minimum requirements in State Energy Code.
Architecturally, the building envelope will be comprised of insulated
walls and roof. Tinted glass will be used throughout the budding.
Electrically, all exterior and landscape lighting will be controlled by
means of time clocks and photocell switches. Energy saving lamps,
ballasts and fixtures are being considered at cores and public spaces.
(e). Historic Buildings
There are no historic structures located on the property.
(f). Environmental Zone
The property is not located within an environmental preservation district.
•
•