HomeMy WebLinkAboutSite Utility Study• • Royal Atlantic Tract "A", Sportsman Park, Section "A" MAJOR USE SPECIAL PERMIT SITE UTILITY STUDY PREPARED FOR Royal Atlantic Developers by: KIMLEY-HORN AND ASSOCIATES, INC. 420 LINCOLN ROAD, SUITE 353 MIAMI BEACH, FL 33139 OCTOBER 2003 Kimley-Horn and Associates, Inc. • • Royal Atlantic Tract "A", Sportsman Park, Section "A" Site Utility Study Introduction The project lies within a 6.31+/-acre property known as "Tract A, Sportsman Park, Section A", and is located along the south bank of the Miami River, near the intersection of NW 7th Avenue and 11th Street, in the City of Miami, Miami -Dade County, Florida. (See site location map -Fig 1). The proposed mixed use development includes two condominium towers with 744 high density residential units, office space, retail space and approximately 968 parking spaces enclosed within two 6-story parking garages. I. Drainage Existing Drainage A platted utility easement containing a 12-inch City of Miami storm sewer outfall exists within the property. It begins near the intersection of NW 11 th Avenue and NW South River Drive and proceeds north across the property to the Miami River (Refer to sheet 24-9 of the City's "Underground Records" in Attachment B). This system collects runoff from adjoining roadways and does not serve the existing property. There are several existing drainage inlets visible within the property. These inlets most likely connect to an onsite drainage system consisting of either drainage wells and/or French drain, with possible overflow to the River. Proposed Drainage System The drainage system for the development will consist of a series of drainage wells. This will allow the stout! runoff to be fully contained and disposed of on site. The project will be designed consistent with a 5-year design storm event, in accordance with Section D-4, Major Use Special Permit Site Utility Study Royal Atlantic, Tract "A", Sportman Park, Section "A" City of Miami, Florida Page 2 • • • Figure 1 1 1 I[[[I I ' NW 5TH ST kN4 5TH ST . Q—�:r.� �� I 1 T a Q (I, I NW 4TH 5T N� _ NaN 3Rii STD Z 1/7/././ NtiV 7JH PROJE Nw 4 T H Nit 3RD ST "Water Control", of Part 2 of the Miami -Dade County Public Works Manual. It is anticipated that six (6) 24" drainage wells will provide sufficient capacity to dispose of the design stouni runoff contributed by the proposed development. Preliminary drainage computations for the project areas are provided in Table 1, which includes the basis for design. The final drainage design for the project should be in confoiiiiance with the requirements Major Use Special Permit Site Utility Study Royal Atlantic, Tract "A", Sportman Park, Section "A" City of Miami, Florida Page 3 • of the Miami -Dade County DERM Water Control Section, Florida Department of Environmental protection, and other local, State and federal regulatory agencies having jurisdiction over the project. II. Water Distribution System Tablel depicts the water mains owned and operated by Miami -Dade Water and Sewer Department (MDWASD), within the vicinity of the project. Table _ Existing Water Mains AIong the south property line on NW 7`h St In accordance with MDWASD criteria, the developer will be required to construct a new 12- inch ductile iron (DI) watermain, In order to achieve the minimum flow rate of 3,000 gpm at 20 psi residual pressure, as required for fire protection, the onsite watermain should be connected to the existing water distribution system at two different points. Probable points of connection include NW 7th Street, near the SE corner of the property, and along the right-of-way of NW South River Drive, beginning at the west end of the property and connecting to the existing 20-inch watermain at NW 1 1 th Avenue. A final determination of points of connection will not be provided by MDWASD until a Water and Sewer Agreement is requested by the developer. Service lines for domestic water, fire sprinkler systems and irrigation could be connected to the on -site water distribution system. Water service meters Major Use Special Permit Site Utility Study Royal Atlantic, Tract "A", Sportman Park, Section " A " City of Miami, Florida Page 4 • • would need to be purchased and installed by MDWASD forces. A copy of the MDWASD water atlas sheet for the project area has been attached (see attachment "B") ICI. Sanitary Sewer Collection System Table 2 depicts the sanitary sewer mains owned and operated by Miami -Dade Water and Sewer Department (MDWASD), within the vicinity of the project. Table2: Existing Sanitary Sewer Mains Along the south property line on NW South River Drive. Along the west property line on NW 1 l Ave A copy of the MDWASD Sewer Atlas sheet has been attached (see attachment B) The proposed on -site sanitary sewer system for the property can be connected to the either of the existing mains abutting the property. However, connecting to the existing l 0-inch mains is preferable, provided that they have the capacity to handle existing flows plus the additional flows contributed by the proposed project. A letter of availability and further coordination with MDWASD is recommended to verify proposed sanitary sewer service connection points for this project. Major Use Special Permit Site Utility Study Royal Atlantic, Tract ` A ", Sportman Park, Section `A" City of Miami, Florida Page 5 • The flows from the existing MDWASD sanitary sewage mains abutting the property are received by MDWASD Regional Pump Station #1, which is a major County regional pump station located at 390 NW North River Drive. As of July 30, 2003, this pump station time is operating at an average yearly NAPOT of 4.36 hours, which is approximately 44% of the maximum capacity allowed by the USEPA. A copy of the Pump Station Monthly Reporting Information provided by Miami -Dade County DERM is provided in Attachment C. It is not anticipated that improvements to the regional pumping and/or transmission systems will be required to handle sewage flows from the proposed project. However, a final determination regarding the status of the existing transmission system and the need for possible improvements will not be made until construction plans are submitted to the Miami -Dade County DERM Wastewater Section and a Sanitary Sewage System Capacity Certification Letter is issued. The additional flows created by these projects have been determined and are shown in Table 3. Table 3: Water & Sewer Flow Generation yry�yyryy [[hh `n JJ �i.rb {iA Nfi4(�.•P- ,...;_ .-:..Y��[" " " am- 4 • f s`r. ..H,.., F �u y� 4 4. '�✓' l `� ^.. b£ �} y��py,,, `C. ✓.'� �'7 e g` C :,� �y Town home 30 units 250 gpdit 7,500 Condominium 714 units 200 gpd/unit 142,800 Retail 9,400 sf 5 gpd/ 100 sf 470 Office 560 sf 10 gpoll00 sf 56 Total Average Daily Flow (gpd) 150,826 Major Use Special Permit Site Utility Study Royal Atlantic, Tract "A", Sportman Park, Section "A" City of Miami, Florida Page 6 • • • IV. Solid Waste Generation Solid waste generated by this project will be collected in standard on -site containers for refuse and recyclables. Regular pick-up service will be provided either by private hauling companies and/or by the City of Miami Solid Waste Department, who will transport the waste to Miami -Dade County's or private disposal and recycling facilities. The volumes of solid waste projected to be generated by the project are shown in Table 4, below. Table 4: Solid Waste Generation .�6�✓ u[ai# t a�..✓'*t r om iv sag Rate \4t `,r" r' ..`7'r" Ki. d �t � e e �- G4ne�-��xid .'� G. V J'" - Y"'T .._ S'..` pc @ {x .�2'x5 Town home 30 units 5lbs/unitlday 150 Condominium 714 units 5lbs/unitiday 3,570 Retail 9,400 s.f 6lbs/1000 sf /day 56.4 Office 560 s.f 6lbs/1000 sf/day 0.09 Total Solid Waste Generated (tons/day) 1.89 Major Use Special Permit Site Utility Study Royal Atlantic, Tract "A", Sportman Park, Section "A" City of Miami, Florida Page 7 o • • Attachment A Drainage Well Calculations Major Use Special Permit Site Utility Study Royal Atlantic, Tract "A", Sport/nanPark, Section "A" City of Miami, Florida Page 8 • • Royal Atlantic City of Miami, Florida )RAA.LCULATION 1. Site Data: A. Control Water Table Elevation F. Proposed drainage inlet grate elevation = 2. Total Site Area (A) = A. Impervious Areas: a) Asphalt and concrete pavement = b) Roof areas = Total Impervious Area (Al) = 0. NGVD (Mean High Tide elev. per MLW Bay Datum) .00 NGVD 6.310 Acres (see Drainage Areas Map in Appendix B) 70. Acres .696. Acres 4.430 Acres (70%) B. Pervious areas: a) Green Areas (NW 2nd Street) = 18$O' Acres (30%) 3. Weighted Runoff Coefficient (C): Runoff Coefficient Impervious (C1) _ Runoff Coefficient Pervious (C2) = C=[(A1 xC1)+(A2xC2)]/A; C= C x A= Total Contributing Area; C x A = 0.721 4.55 Acres 4. Time required to generate one inch of runoff (per DERM Water Control Section D-4) Rainfall Intensity (I) = 308.5 / [(48.6 x F"°'t t) - t (0.5895 + F-2/3)] Frequency (F) . S years - Frequency Curve Q = CIA, V = Qt; V(i in.) ` Qt(1 in.)to in.) Time to generate 1 inch of runoff V{tin.) = CIAt(t in.) 1" x A = CIAt(1 in.) Solving for t(t in_), t(t i,,.) = 1" / (IC) Time to Generate one inch of run-off t(in) Time to reach the inlet (tc.) Total Time required to generate 1 in of runoff: = 14.66 Min. = 10.00 Min. 24.66 Min. H:1042145000 (sportsman Park)1DrainagelDrainCaics.xls BASIN • • • 8. Excess storm water runoff excluding well structure storage: • 8 10 15 24.66 30 40 50 60 90 120 180 480 600 900 1,4751.72 1800 2400 3000 3600 5400 7200 10800 45.12 45.12 45.12 45.12 45.12 45.12 45.12 45.12 45.12 45.12 45.12 +ccun1LiTated Fe11 Discharge 21,658 27,072 40,608 66,766 81,217 108,289 135,361 162,433 243,650 324,866 487,299 Aecptr�ulated 8tiin Runoff ...................................................... (CF) 13,991 16,838 23,106 32,621 36,807 43,214 48,253 52,320 60,872 66,289 72,765 -7,666 - 10,234 -17,503 -34,145 - 44,409 -65,075 -87,108 -110,113 -182,778 - 258,577 -414,535 9. Excess storm water runoff including well structure storage: Safety Factor 1"iCGtu It is Well Y " f Aectttnula torag a 17ischarge Ta - Verllow. torm R nof1 e11 Structure Vo c l m 8 480 13,991 2,025 21,658 -9,691,45 10 600 16,838 2,025 27,072 -12,259.32 15 900 23,106 2,025 40,608 -19,527.51 24.66 1,479.72 32,621 2,025 66,766 -36,170.11 30 1800 36,807 2,025 81,217 -46,434.23 40 2400 43,214 2,025 108,289 -67,100.07 50 3000 48,253 2,025 135,361 -89,133.19 60 3600 52,320 2,025 162,433 -112,138.09 90 5400 60,872 2,025 243,650 -184,803.07 120 7200 66,289 2,025 324,866 -260,602.25 180 10800 72,765 2,025 487,299 -416,559.54 2.05% Safety Factor 2.18% H 1042195000 (sportsman Park]1[3rainagetDracnCaks xls WELLS • • • 5. Cumulative Runoff (Inflow Mass Diagram) (mi (Sec.) Accutnulated. tt3nn Runoff 8 10 15 24.66 30 40 50 60 90 120 180 480 600 900 1480 1800 2400 3000 3600 5400 7200 10800 4.551 4.551 4.551 4.551 4.551 4.551 4.551 4.551 4.551 4.551 4.551 6.405 6.166 5.641 4.844 4.493 3.956 3.534 3.193 2.477 2.023 1.480 29.15 28.06 25.67 22.05 20.45 18.01 16.08 14.53 11.27 9.21 6.74 13,991 16,838 23,106 32,621 36,807 43,214 48,253 52,320 60,872 66,289 72,765 6. Drainage Well Design Discharge Rate: Based on well discharge rate of: `ry 15p. GPM/ft. Head E 4 «� r"4 :- t o {�ly�u S ...' e� �% q G 'Di�r. earilcts IE44. tgh rS �o f e x x �G ft ft.)'� fix Well Strunne cture 13nstons pry.. 11 trtt4,4: r .sue` �:. t ge n �We traito' #. 3 �y' U ( y �5- .` "� ' DW-1 8.00 2.00 1.50 4.50 7.52 = �� )2.5 '' 15` 337.5 337.5 DW-2 8.00 2.00 1.50 4.50 7.52� u` DW-3 8.00 2.00 1.50 4.50 7.52 f . 5: 337.5 DW-4 8.00 2.00 1.50 4.50 7.52 „ 6 0 12.5 x 337.5 DW-5 8.00 2.00 1.50 4.50 7.52 6.0: 12.5 337.5 DW-6 8.00 2.00 1.50 4.50 7.52 O 1' :' 337.5 Well Discharge Rate (CFS) 45.12 7. Detention Time: Total Storage (CF) 2025.0 The drainage well structure must be designed to detain runoff for a minimum of 90 seconds prior to discharge. Qd = Design Runoff Rate (CFS) = Vd = Detention Volume (CF) = Qd x 90 sec. Vdi = Detention Volume Per Well (CF) W = Width of Well Structure (ft.) L = Length of Well Structure (ft.) 22.05 CFS 1984.05 CF 330.68 CF 6.0 ft. 12.5 ft. is the minimum depth required from the top of well casing to the floor of the well box to achieve 90 second detention time: Hm,n. (ft) = Vd, i (W x L) = 4.50 ft. Top of Well Casing Elev. = 4.00 (Approximately 4 feet below rim elevation) Elevation at Floor of Well Box (NGVD) = Top of Well Casing Elev. - H;,,. =-0.50 H.1042195Q00 (sportsman Paek}lhrainagelikainCaksxls WELLS • • Attachment B Existing Utility Records Major Use Special Permit Site Utility Study Royal Atlantic, Tract "A", Sportman Park, Section "A" City of Miami, Florida Page 9 INSTALLATION WATER MA .;'°: • 155Z3 7 • 413_9 • 312 4 2 " 313 NW7 S311 307 42" "314 �r \\315 5667 2 326 / 3567 • 327 328 3568 `1 NWasT 302 304 306 / 43D4 330 wrr17 � 303 300 5667 3472 \1 / 89 3 58 7 \1i NOTE: ALL GRAVITY SEWERS ARE 8" UNLESS OTHERWISE DES 31 299 298 22 3 58 6 �1 3534 7 - . • • 1-5W/t/k- ,_. . vk ,•-j ,,,, _, c- ,.- '1 .1--.„. o q1 ck 1,....7 L. 4-1 i\14\16 5 RAVER. ORM/E. Ni:km.. 11bAuE— ki . "1" • • • Attachment C Pump Station Monthly Information Major Use Special Permit Site Utility Study Royal Atlantic, Tract "A", Sportman Park, Section "A" City of Miami, Florida Page 10 Itation 30 -000 Pump Station Monthly Atlas Pg..F14 ''TIAMI DADE WATER & SEWER DEPARTMENT of ormat ion <Plan Review> Moratorium..OK ddr..390 NW NORTH RIVER DR ec-Township-Range 1-54-41 4nr._ ET clock.Y Telm.Y #Pumps. 8 p Type.A Stn Class.M Speed 2 Hrspwr.+ m Res ' Plans.. Plats.. Extens. flow(gpd) 7,546,564 0 Proj Napot 5.72 hrs 4.36 hrs 4.36 hrs Cap 57.20 43.60 43.60 Date Mo.NAPOT Avg Daily Flows 6/25/2003 '05/27/2003 ..04/25/2003 R3/27/2003 2/26/2003 01/27/2003 2/23/2002 95 GOLD/M HiOLD/D OLD/G 5.95 5.24 4.19 4.63 3.93 41.63 36.66 29.31 32.41 27.54 Moratorium effective since / / Yearly NAPOT (hrs) 4.36 Stn Gross Capacity(gpd)..221,760,000 Station Reduction Factor 0.60 Stn Net Cap Certif(gpd).. 0 Stn Net Capacity(ypd)....133,056,000 Indicated Flows(gpd) 24,171,840 Rgd # Fig Pmp 0.00 Y 8 0.00 Y 8 0.00 Y 8 0.00 Y 8 0.00 Y 8 Y_ 8 Y 8 3.81 26.70 0.00 3.72 26.05 0.00 Signature..LEALG Station I<m>provement GOLD/S <D>ownstream Station Codes & Cata<g>ories GOLD/T Comments Sign Date. <S>tation Inform. .04/09/2003 14:12:16.50 GOLD/U <U>pstream Statior. GOLD/P <P>ump Informatior Sewer Cer<t>ification �2003073011525832*DEAR MM * This ±.s not an official docurn nt_ - * M Stat Station Station Current Delta Projected iType Owner Number ET (Hrs) ET (Hrs) ET (Hrs) roposed Number of gallons (gpd): 500 t *************************** Downstream Stations ***************************** A52M+ 30 0001 5.72 0.00 5.72 N 30 CD 1002.16 0.00 1002.16 AC 30 RS 1002.01 0.00 1002.01 JN 30 RS95APR 1001.74 0.00 1001.74 N 30 RS94MAR 1001.87 0.00 1001.87 A 4 1 nt