Loading...
HomeMy WebLinkAboutSite Utility StudyFLS FORTIN, LEA VY, SKILES, INC. CONSULTING ENGINEERS, SURVEYORS & MAPPERS 180 NE 168 Street/North Miami Beach, FL 33162 Telephone: (305) 653-4493 Facsimile (305) 651-7152 e-maile fls@flssurvey.com THE GABLES MARQUIS Site Utility Study May 6, 2003 Prepared By: Fortin, Leavy, Skiles, Inc. Job No. 27063 By: P.E. Florida Reg. No. 1 617 O:AArchives120021Eng.3obs127O63GablesMarquisSiteUtilityStudy.ks.doc FLS FORTIN, LEA VY, SKILES, INC. CONSULTING ENGINEERS, SURVEYORS & MAPPERS 180 NE 168 Street/North Miami Beach, FL 33162 Telephone: (305) 653-4493 Facsimile (305) 651-7152 e-mail: flsaJlssurvey.com SITE UTILITY STUDY LOCATION The site is located at the east end of the block bounded by S.W. 22" d Street (Coral Way, State Road 972) on the north, S.W. 32nd Avenue on the east, and S.W. 22na Terrace on the south. II. PERMITS In addition to City of Miami approvals, permits will be required from the Florida Department of Transportation for the driveway connection to Coral Way and for site drainage improvements, and from DERM for site drainage. The developed site will have less than 2.0 acres of impervious surface and an Environmental Resource Permit will not be required. III. DRAINAGE Existing site elevations vary from a low elevation of 10.5 N.G.V.D. to a high of 14.8 N.G.V.D. Exfiltration trenches are being used for on -site drainage. Drainage for the proposed development will be provided by exfiltration trenches. Drainage Data for Proposed Site: Net Area Pervious Area Impervious Area 71,800 S.F.+ 10,350 S.F. 61,450 S.F. = 1.41 Acres The exfiltration trenches will be sized to meet the more stringent of the following criteria: • To retain the first inch of run-off from the net site area. • To exfiltrate the peak run-off from a 5 year — 1 hour storm. • To exfiltrate an amount of run-off to meet FDOT criteria. Based on an expected hydraulic conductivity coefficient of 5 x 10(-4), about 120 L.F. of exfiltration trench will be required to retain all run-off on the site. The DERM water quality criteria will be included in the design of the drainage system, for the paved areas, roof areas and interior garage area. O:IArehives12OO21Eng„ Iobs127063GablesMarquissiteUtilitystudy.ks.doc FLS 1rgaimPrP- FORTIN, LEA VY, SKILES, INC. CONSULTING ENGINEERS, SURVEYORS & MAPPERS 180 NE 168 Street/North Miami Beach, FL 33162 Telephone: (305) 653-4493 Facsimile (305) 651-7152 e-mail: fls@llssurvey.com IV. WATER DISTRIBUTION Domestic water requirements are: Item 11,700 S.F. Retail 8 Townhouses 169 Apartments Demand Total Demand 5 GPD/100 S.F. 585 GPD 250 GPD/Each 200 GPD/Each Peak Demand _ 63 GPM± 2,000 GPD 33,800 GPD 36,385 GPD Existing Miami -Dade Water & Sewer Department water lines adjacent to the site: • Coral Way - 24" CIP • S.W. 33rd Avenue - 16" CIP • S.W. 22"d Terrace - 4" CIP Domestic and Fire connections can be made to either the 24" line in Coral Way or the 16" line in S.W. 32"d Avenue. Depending on fire protection requirements, the 4 inch line in S.W. 22"d Terrace may have to be upgraded to a larger size line. Additional fire hydrants may also be required to be installed adjacent to the site, V. SANITARY SEWERS The average sewage flow from the project will be the same as the average water demand, as calculated above, 36,385 GPD. The peak flow will be 101 GPM±. Existing Miami -Dade Water & Sewer Department sanitary sewer lines adjacent to the property are: • Coral Way - • S.W. 32nd Avenue - • S.W. 22"d Terrace - 10" Gravity Line 8" and 36" Gravity Lines 8" Gravity Lines Existing sanitary laterals are available for connections to all of the existing lines. O:lA.rch ives12002\Fng.Jobs\27063Gab1esMarquissiteUtil itystudy.Ics.doc ipj F LS FORTIN, LEA VY, SKILES, INC. CONSULTING ENGINEERS, SURVEYORS & MAPPERS 180 NE 168 Street/North Miami Beach, FL 33162 Telephone: (305) 653-4493 Facsimile (305) 651-7152 e-mail: fis@fissurvey.com VI. SOLID WASTE GENERATION Solid waste generated by this project will be collected in standardized on -site containers for refuse and recyclables. Regular pick-up service will be provided by either private hauling companies and/or The City of Miami Solid Waste Department, who will transport the waste to Metro -Dade County's Disposal or Recycling facilities. The projected daily volumes of solid waste generation are shown below. Residential Apartments and Townhomes (177 Units @ 1.42 tons/unit x 2,000 lbs/ton)/365 days = 1,378 lbsiday Retail (11,700 ft2 @ 3.08 lbs/ ft2)/365 days 99 lbs/day Total = 1,477 lbs/day O:1Archives120021Eng.lobs127O63Gab1esMarquissiteUtilityStudy. ks.doc