HomeMy WebLinkAboutR-80-0636I RFC/bbb 9/15/80 RESOLUTION NO. 8 0- 6 3 6 A RESOLUTION APPROVING THE DESIGN DEVELOPMENT AND WORKING DRAWINGS OF THE PARKING GARAGE TO BE CONSTRUCTED BY MIAMI CENTER ASSOCIATES, INC. PURSUANT TO THE AGREEMENT ENTERED INTO BY THE CITY OF MIAMI AND MIAMI CENTER ASSOCIATES, INC. ON JULY 11, 1980; FURTHER SETTING FORTH THE AGREED FINAL CONTRACT PRICE AND ACKNOWLEDGING THAT THE CITY HAS GIVEN WRITTEN NOTICE TO THE DEVELOPER THAT FUNDS ARE AVAILABLE FOR PAYMENT OF SAID CONTRACT PRICE; AND AUTHORIZING AND DIRECTING THE CITY MANAGER TO ISSUE THE NOTICE TO PROCEED PURSUANT TO PARAGRAPH 4.1 OF THE SAID AGREEMENT. WHEREAS, Section 4.1 of the Agreement between the City of Miami and Miami Center Associates, Inc. entered into on July 11, 1980,provides: '.'SUPPORTIVE DP�OCUMEN . FFOLLOW. and "Notice to proceed with the construction shall not be given later than September 1, 1980, provided that in no event shall such notice be given until (i) the City has approved the Developer's plans, including design development, working drawings and specifications completed to the extent provided in Setion 5.1.1 hereof, which approval shall not be unreasonably withheld, (ii) the Parties have agreed upon the final Contract Price, and (iii) the City has given written notice to the Developer that funds are available to the City to pay the Contract Price as provided in subparagraph 3.2.4 of the Con- ditions of the Contract." WHEREAS, all conditions in the quoted paragraph have been met by the parties to the Agreement, although the final working drawings and specifications have not yet been fully completed; and WHEREAS, the City Manager and his staff, including the Executive Director of the City's Off -Street Parking Authority, have recommended the Design Development Plans submitted by Miami Center Associates, Inc. be approved by the City Commission; and WHEREAS, the City of Miami is most anxious for construc- tion of the project to commence as quickly as possible; NOW, THEREFORE, BE IT RESOLVED BY THE COMMISSION OF THE CITY OF MIAMI, FLORIDA: "DOCUMENT INDEX �,'� � 11 Section 1. The City of Miami hereby �i ove0s a Design Development Plans of Miami Center Associates, Inc. for the parking garage,including the requirements but not the "wishes" contained in the letter from Conrad Associates Easti• da+,& ___ September 9, 1980. CITY COMMISSION MEETING OF SEP1 5 wo REsoumoN,8 0 - 6 3 i 00N Sectin 2. The City of Miami hereby approves the working drawings and specifications which are not yet in final form but which have been completed to the extent provided by Section 5.1.1 of the Contract. Section 3. Miami Center Associates, Inc. has agreed that the Contract Price for the Turnkey Project shall not exceed $15,000,000, including a contingency allowance. Section 4. The City of Miami has given written notice to Miami Center Associates, Inc. that funds are available to the City to pay the Contract Price as provided for in the Agreement. Section 5. The City Manager is hereby authorized and directed to issue the notice to proceed to Miami Center Associ- ates, Inc., pursuant to the provisions of Paragraph 4.1 of the aforesaid Agreement of July 11, 1980. PASSED AND ADOPTED this 15th day of September , 1980. Maurice A. Ferre MAURICE A. FERRE M A Y 0 R ATTEST; ?� ALPH JV. ONGIE, CITY CLER S PREPARED AND APPROVED BY: a0C,,,%I 1A,.4 N c ROBERT F. CLARK ASSISTANT CITY ATTORNEY 0VED AS 0 FORK AND CORRECTNESS; E CE F. KNOX, JR.,\CITY ATTORNEY -2- 80-636 � MIAMI CITY COMMISSION September 15, 1980 REQUEST APPROVAL FOR THE CONVENTION CENTER PARKING GARAGE BY MIAMI CENTER ASSOCIATES, FERENDINO/GRAFTON/SPILLIS/CANDELA This Garage: 1. Accommodates 1450 cars. 2. Construction of the parking garage for the $15,000,000 budget. 3. Is capable of supporting a 600,000 square feet Trade Center Office Tower above. 4. Will accommodate the Downtown People Mover Station in its present alignment and design. 5. Will be capable of starting construction October 1, 1980, for completion, together with the Convention Center, February, 1982. 6. Has been approved by both the permanent and construction lenders, Massachusetts Mutual and Continental Illinois National Bank. "SUPPORTIVE DOCUMENTS FOLLOW" IN Ferendino/Grafton/Spillis/Candela architects engineers planners N 8 3 6 -M M "SUPPORTIVE DOCUMENTS FOLLOW TRADE CENTER TOWER Miami, Florida Ferendino/Graf ton /Spill is /Candela Architects t 80,p 6 3,6 r) •ry'; •"SUPPORTIVE DOCUPAENT$ FwL ' JY FYB#Midi 11 ~ 7�, k..", MY 7.{ mi Sr' "SUPPORTIVE DOCUMEN"I 3 MLLOW lN RwOff"Mm"m j -- — - - — _— _ _— -- „a � - vTit` TRADE CEN MIAMI, FL BUILDING GARAGE: PARKI PARKING LEVELS RETAIL SPACE LOADING DOCKS GARAGE ELEVATORS TRANSFER ELEVATORS GARAGE EFFICIENCY COMPACT CARS TRADE CENTER TOWER: 9 20000 SQ.FT. 6 6 AT 500 FT. PER MIN. 4 AT 500 FT. PER MIN. 345.9 SQ. FT. PER CAR 37.5% TOTAL GROSS SQ. FOOTAGE 610,457 SQ. FT. TYPICAL FLOOR 22,600 SQ. FT. EFFICIENCY* LOW RISE - FLOORS 12 THRU 26 - .934 HIGH RISE - FLOORS 27 THRU 41 - .965 FLOOR TO FLOOR HT. 12' ELEVATORS 12 REQUIRED LOW RISE - 6 SERVING FLOORS 12 THRU 26 HIGH RISE - 6 SERVING FLOORS 27 THRU 41 ELEVATOR CAPACITY LOW RISE - 6-3,500 LBS. AT 800 F.P.M. HIGH RISE - 6-31500 LBS. AT 1,200 F.P.M. AVERAGE HALL CALL WAITING TIME LOW RISE - 16.7 SECONDS HIGH RISE - 18 SECONDS * Note: Efficiency based on B.O.M.A. Standards.