HomeMy WebLinkAboutSubmittal-Hector Badia-PowerPoint PresentationSubmitted into the public
record for item(s) RE.3
on 4/13/2023 . City Clerk
Morningside Park Baywalk/Shoreline Improvements
k
Vlf
OL
st`'. �,,
. o; f.
!fit
Ir
1 3352-Submittal-Hector Badia-PowerPoint Presentation
Curtis + Rogers Design Studio, Inc.
Morningside Park Waterfront Improvements
Coastal Systems International
toe
-Ao
PROPOSED DESIGN BASED ON CRITERIA FROM COMMUNITY WORKSHOP
Submitted into the public
record for item(s) RE.3
on 4/13/2023 . City Clerk
Enhanced Kayak Ramps
72' from center of Boywolk Water Access to Proposed
to Edge of Water Floating Pier 65' from center of Baywalk
; to Edge of Water
t
LEGEND l7.!
• Resilient Components
- - *Viewing outlook • Stabilized and increased softtrail
- - i Water Access • Elevated baywalk
• Enhanced and accessible viewing outlooks
Unobstructed Views to be Preserved . Increased sitting areas
Sodded Areas • Increased ADAAccessibility
ADA Accessible Baywalk • Increased natural shade ( Tree Canopy)
• Nightime Security Lighting
ADA Accessible Picnic Tables • Drainage Improvements
t� v. • Pedestrian and VehicularManagement
City of Miami I Morningside Park
Waterfront Improvements
01/2023
Morningside Park Waterfront Improvements
Total Project Site Area: 393,303 SF 19 Acres
Total (Proposed + Existing) Canopy Area: 196,429 SF = 5Vo
Area without Canopy: 196.874 SF = 50%
e
Y
50 PO
y� pp / s
1 i
I �
t&�Mv,
1
f
f � g
Total IPropasetl' Uialiog) Canopy Area {50%) NeW Proposed CWoAy Area t29%1
• Area without Canopy f!50%1 • EcisYng Canopy Area to ha RoloCaged (1%)
■ Ewsting Canopy Area 1n Ramain )20%)
■ Area*Ihoul Canopy t 50%)
L�
u•a
Existing
Viewing Outlook
Unobstructed views to be preserved.
ADA Accessible Baywalkj�llllAlllllllj
VII,
Ale- ®R i
.g
-rum . I--
T4 '�i, 4y. Y �. 9F Y.'� i4" �. . � = f �� �z. � .ice^=� � _ ?� J!r 6u� 4 ''6
X_
Existing
Vi
ewing Outlook
Vol
Raised -foot -wide wa . i g . oat h aligned with trees to provide s
and surface change to pervious m aterial to improve drainage
ADA Accessible pathway along wAeT'_-
L?
First Tier Attenuator
PROJECT ASSETS '
• Maintains general park character '
• Provides 1 st and 2nd Stage attenuators protecting '
park and neighborhood .
• Storm surge waters return to Bay •
• Pedestrian and vehicular traffic is separated
• Baywalk meanders around exisfingtrees
Submitted into the public
record for item(s) RE.3
on 4/13/2023 . City Clerk
Shoreline grass protects surface from erosion
Bay view opportunities are preserved
Enhances existing open space utilization for general public
enjoyment
ADA accessibility throughout baywalk and shoreline
Design will assist City in reclassifying flood zone of park
from VE to AE ( subject to FEMA approval)
Drainage installation will reduce flooding duration
AERIAL VIEW RENDERING Connecting Morningside Park Waterfront Improvements
NATURE PEOPLE WATER
CHALLENGES CREATING A SEAWALL AT WATERS EDGE
Existing Edge Conditions- nativevegetation&mangroves
Existing Edge Conditions- boat launch area
AERIAL VIEW RENDERING
Submitted into the public
record for item(s) RE.3 ,
on 4/13/2023 . City Clerk
• Impactto existing native vegetation & mangroves,
requiring significant mitigation
• Removal and significant mangrove impacts
• Storm surge waters return to Bay
• Regulatory agency permitting would require
significant resources and years to approve if at
all.
• Backwash from storm surges creates scouring along
bulkhead undermining uplands
• Restricts storm surges from flowing to bay
• FDEP has stated that vertical seawalls may not always be
the best option for shoreline stabilization.
• Change of Park Character
• Restrict access to water
• Ladders or ramps required to access bay
Alice Wainwright Park Shoreline
Morningside Park Waterfront Improvements
Submitted into the public
record for item(s) RE.3
on 4/13/2023 . City Clerk
A RESTORATIVE & INCLUSIVE LANDSCAPE
Connecting
NATURL PEOP11 WATER
AERIAL VIEW RENDERING Connecting Morningside Park Waterfront Improvements
NATURE PEOPLE WATER
Morningside
Park I [design
Benefits
+223
6 d
u u
Peaches (ea)
+60
Outdoor Tables (ea) nit
+253
Accessible
Paywalk (lf)
+125%
Net Trees
+109%
Canopy Area (sf) At
Submitted into the public
record for item(s) RE.3
on 4/13/2023 . City Clerk
Existing 13
Proposed 42
Existing 10
Proposed 17
Existing 1,380 -
Proposed 4,867 -
Ex -Is L1rtj 359
Proposed 806 -
Existing 94,167 -
Proposed 196,42.9 -
Morningside Park Waterfront Improvements
UPDATE SINCE 3-10-2022
• Commission approved R-22-0116 with
an Action Plan to commence with the
following:
✓ Pool Complex
Submitted into the public
record for item(s) RE.3
on 4/13/2023 . City Clerk
i��1 rat r,
w�rM
Miami oDO:X1
0,1'IOIVfS)
e
FL M
9_11,
+
l
Resolution
! ,
R-22 0116
A RESOLUTION OF THE MIAMI CITY COMMISSION, WITH ATTACHMENT(S), APPROVING
THE CONCEPTUAL DESIGN PARK MASTER PLAN TO IMPROVE MORNINGSIDE PARK
PRESENTED BY THE ADMINISTRATION, ATTACHED AND INCORPORATED AS EXHIBIT w-,
demolished. SUBJECT TO FURTHER REVIEW BY THE CITY COMMISSION OF THE DESIGN AND
LOCATIONS OF THE POOL AND LOOP ROAD; RESCINDING ANY AND ALL PRIOR
CONFLICTING RESOLUTIONS.
✓ Baywalk and Shoreline project
design in accordance with Exhibit
"A" and presented to Commission.
✓ LOMR application submitted to
FEMAfor flood zone reclassification.
✓ To further discuss the location of the
new aquatic pool
of LOMR.
based on outcome
Information
Department: Department of Parks and Sponsors: Commissioner Ken Russell
Recreation
Category: Other
Attachments
Agenda Summary and Legislation
11198 Exhibit A
11198 Submittal -Elvis Cruz-Pou:erPoint Presentation
11198 Submittal -Parks and Recreation Department-PowerPoint Presentation
11198 Submittal - Daniel hialaid - Morningsde Park Survey
11198 Submittal - Elvis Cruz - Petitions for Momingside Park
11198 Submittal - EIVis Cruz - Pac;erPoint Presentation 3-16-2022
Body/Legislation
WHEREAS, the City of Miami ("City") is in the process of designing improvements to Momingside Park
located at 5215 Northeast 7Avenue, Miami, Florida: and
WHEREAS, the Administration has presented a conceptual design park master plan to improve
Morningside Park, attached and incorporated as Exhibit 'A::: and
WHEREAS, it is in the best interest of the City to approve the conceptual design park master plan
presented by the Administration and rescind any and all prior conflicting resolutions;
NOW, THEREFORE, BE IT RESOLVED BY THE COMMISSION OF THE CITY OF MIAMI, FLORIDA:
11
Section 1. The recitals and findings contained in the Preamble to this Resolution are adopted by
reference and incorporated as if fully set forth in this Section.
Section 2. The conceptual design park master plan to improve Morningside Park presented by the
Administration, attached and incorporated as Exhibit `A," is hereby approved subject to further review by the
City Commission of the design and locations of the pool and loop road.
Section 3. Any and all prior conflicting resolutions are hereby rescinded.
Section 4. This Resolution shall become effective immediately upon its adoption and signature of the
Mayor[i]
Building Height Related to rioon r nnip
(Current FFM® Flnnil 7nnp nPezi ,nnrinnS 1
1mmnrnvP mPnrC. I
• Under FEMA current flood maps, there are 3
flood zones in the park.
• Zone VE requires lowest horizontal structures
to be built above the Base Flood Elevation of
10' (i.e., FFE= 10'BFE + 1' freeboard).
• Zone AE requires structures associated with
habitable floor areas must be built above the
Base Flood Elevation of 9' (i.e., FFE= 9' BFE+
1' freeboard)
• VE Zone —New pool building height will be 24'
• AE Zone — New Pool building height will be 17'
• A7' height difference between locations.
VE ZONE
EXISTING GROUND ELEVATION = 5.8'
Submitted into the public
record for item(s) RE.3
on 4/13/2023 . City Clerk
AE ZONE
Submitted into the public
record for item(s) RE.3
on 4/13/2023 . City Clerk
Building Height Related To Flood Zones (With Baywalk ai._
Seawall Improvements
• City applied for a Letter of Map Revision
(LOMR) and provided engineering studies,
engineering improvements and analysis to
reclassify the park potentially into an AE
Zone.
• The LOMR is requesting a Zone AE at 10'
BFE.
• If approved by FEMA, Zone AE Zone —
New Pool building height will be 17'
VE &t Coastal AE ZONE
-------- ---I ---- 1
BATH AND P-P HOUSE
-i- ------------------ 17' BFE+ 1' = 11' (AEZone - LOMR)
5 (8'-O'DEEP)
-- __-f -_. __------ EXIS-nNGGROUND ELEVA-nON= 5.8'
I i
Types of Flood Zones
• Zone VE: waves and fast-moving water
can cause extensive damage. Wave
heights of 3 feet or higher are expected
• Coastal Zone AE: waves and fast-
moving water can cause extensive
damage. Wave heights of 3 feet or less
are expected.
• VE Zone Standards - Buildings must be
elevated on pile, post, pier, or column
foundations, and must be adequately
anchored to the foundation. Structural
fill is prohibited. The bottom of the
lowest horizontal structural member be
at or above Base Flood Elevation (BFE).
Submitted into the public
record for item(s) RE.3
on 4/13/2023 . City Clerk
LIMWA
COASTAL COASTAL HIGH
A ZONE HAZARD AREA
AE AE VE
Wave Height < 1.5ft 3ft > Wave Height >_ 1.5ft Wave Height >_ 3ft
Flood Zone Reclassification Activities
LIMWA Management
• LIMWA— Limit of Moderate Wave
Action. Post -storm damage shows that
even 1.5' waves can cause significant
damage to buildings that were not built
to withstand them. To highlight this risk
on flood maps, it is shown as black
line with arrows.
• Due to the higher risk of wave damage
to structures, FEMAencourages VE
Zone floodplain managements
standards in Coastal AE Zones.
• These require buildings in the Coastal
Zone to meet Zone VE standards.
• Adopting higher construction and
floodplain management standards in the
Coastal AE Zone may also reduce flood
insurance premiums.
Submitted into the public
record for item(s) RE.3
on 4/13/2023 . City Clerk
LIMWA
COASTAL COASTAL HIGH
A ZONE HAZARD AREA
AE AE VE
Wave Height < 1.5ft 3ft > Wave Height >_ 1.5ft Wave Height >_ 3ft
Submitted into the public
record for item(s) RE.3
on 4/13/2023 . City Clerk
Building Height Related To Flood Zones (Proposed FEMA Floc,_
Zone DesignatR __
• FEMA's proposed changes, if approved, the park area
will have one designated flood zone
• Coastal Zone AE requires lowest horizontal structures
to be built above the Base Flood Elevation of 8' (i.e.,
FFE= 8' BFE+ 1' freeboard).
• Coastal Zone AE requires structures associated with
habitable floor areas must be built above the Base
Flood Elevation of 9' (i.e., FFE = 9' BFE + 1'
freeboard)
• FEMAdid not make changes to the flood zones in
Morningside Park. FormerAquatic Pool Complex is
still in VEZone; The Community Center is in AE Zone.
• Zone AEZone —New Pool building height will be 22'
• No change in building height regardless of location
VE 8t Coastal AE ZONE
BATH AND PUMP HOUSE
t
WIMMING POOL
0
BFE+ 1' = 9' (Coastal AE Zone)
-------------------------------------------------------
EXISTING GROUND ELEVA-nON = 5.8'