Loading...
HomeMy WebLinkAboutM-88-0426It o—=33 T11r=0011;� t d I=-V Si_lt•at4l=L W"Nr fi tlr dItY OP MIAMI. F LORIOA tb. t�1lg�la R. l�ellafny DAtE May Assistant. city MAnpger sue�tct. estua samplo6 OPAOM REf-ERENCE9 Rene Larrieu, r. Aaeistant Director Department of Personnel Management IENCLOSURF9 The purpose of this memorandum is to provide you with a status report can the City Commission's request for the Department of Personnel Management to obtain a proposal. to evaluate the cost of having asbestos samples taken of all City buildings with possible asbcstos-containing material. As you are aware, the Safety Coordinator, Alberto J. Rodrigue.z, made a preliminary presentation on this topic at a City Commission meeting in April. At that City Commission meeting it was decided that we should cost out this project prior to Implementation. Rs you can see in the attached proposal, it will cost the City of Miami $375.00 to have 25 samples taken of four City buildings. 'The �I cost is reduced as Alberto has negotiated a flat fee of $15.00 per sample instead of the going rate of $25.00 per sample. Please advise if you wish tie to proceed to have the samples taken ' as outlined in the attached proposal. Also, please advise as to ,? which account should be charged for this project-. RPL:vbd Attachment t111`r'-- 1►�— n. tLJIE S 54-r V`��0f4f4L-L h `T' Advanced 1I�d�istt'�sil Hygiene Services, Inc. _ All Faepts of Industrial Hygiene Ser%flce ,r Albetlo J. itodrigutz Aptil 28r 1900 Safety Coordinator Department of personnel Management City of Miami P,O. hox 330708 Miami, Florida 33233-0708 lZet Proposal for the collection and analysis of air samples for <--'f fiber cbni 6iit' T'Ol 74-0-met1iod)'and- saWOIi ig and •• ana-lysia - of bulk materials for asbestos content (polarized light/dispersion staining microscopy) in the following four (4) city owned and operated buildings: 1. Stephen Clark Building 1650 N.W. 37th Avenue Miami, Florida ?; 2, parks and Recreation Main Office 1390 N.W. 7th Street r' Miami, Florida 3. City of Miami police Department 400 N.W. 2nd Avenue Miamir Florida rE: 4 2600 South sayshore DriveaTll Miami, Florida •�• s= _ AIHS Project c_1026-002• Advanced Industrial Hygiene Services, inc. is pleased to submit the following proposal for bulk suspect asbestos containing building materials sampling in the above listed buildings. The bulk sampling regimen proposed here would constitute Part i of a two Part project. The second part deals with air monitoring in those areas where the bulk sampling indicated the presence of friable asbestos and will be proposed based on the results of Paxt I. 9S-42F 21.31 SAV. 2nd Avenue a Miami, Florida 33129 a (305) 854.7554 1 0- -+ }.1q`i.- i ice- e t 1_i : 48 1`E:iZc0t4t49=U t•100-i- bulk Sampling Ptolocol Fart Y f Y " 4 building 1!1 Stephen Clark building -- This building has a sprayed -on acoustical. cef lag. RPM► recommends that 9 bulk samples be collected in order to account for irregularities in the composition of the sprayed -on material. Tothl''number of bulk sam'pZes= ....4 .., . building A2 Parks and Recreation Mein office - This building also has a sprayed -on acoustical ceiling on both of it's two floor.". rn many areas, Especially on the first floor, the sprayed -on material is hidden by a drop ceiling of acoustical boiling tiles. Again, 9 bulk :samples are recommended with an additional three samples of representative acoustical ceiling tiles (since these, may also contain asbestos). Total number of bulk samples: 12 Muilding S3 City of Miami Police Department -- This building has friable sprayed -on fire proofing applied on the underside of each floor. As with muilding #2, much of this material is concealed by )acoustical ceiling tiles in a suspended ceiling. This material is visible and exposed in th6 .basement_ floor weight room and in the air, -hatfd1cY''r66fns. rt is rec4mmenzied that 2 bulk samples of: this material be Collected as well as 2 samples of representative acoustical ceiling tiles. Total number of bulk samples: 4 i� Hui1dinq #4 2600 south bayshore Drive - This building has suspect acoustical ceiling tiles in a suspended ceiling. Damage to several of the tiles caused concern to some of the employees of the affected area, t his recommende3d that a sample of a representative the be collected. Total number of bulk samples; ^1 1 �f o 111 4 */M !q ,S ' P1 V ;' — i r_a — : t i_I t '� s 4 9 1— tF P to r'1 L r�''� \T Tgta1 number of bUik gdmp1e5 proposed in Part I:21e 25 Total cost of implementation of pant i:.�� a Ql ea Please dote that the cost of $15.00 per sample with no additional sample/travel time charges is a special rate offered to the City of Miami as a preferred and very valued client. It is recommended that Part II, Air Monitoring, b6 de6lgned following the..results.of_Part. I_.._Ai.r.mo.nitor-ing;will-also be offered to the City of Miami at a rat e of"$15.ii0 per.'sampl�..�rith... no additional sample/travel time charges. Advanced Industrial Hygiene Services, Inc. is tileased to offer this proposal. Please contact this office should you haveany G: questions or comments concerning this proposal or any related �; matter.