Loading...
HomeMy WebLinkAboutExhibit ASPECIFIC PURPOSE SURVEY LOCATION MAP: w �I `F� ¢ z IJGTy 4th S NW 4th ST w NW 4th ST a z Q LLJ z NW 3rd ST z NW 3rd ST I Z 92i z NW and ST Q z f = NW 2ND ST NW and ST �r u O r L 1� NE 1st ST z m f a � z NW 1st ST a z f 3 z W ST FLAGLE ST EE W ES FLAG ER STR ET a 41 SW 1st ST SW 1st S SW and ST W and S wY Q W 3r ST � N SW 3rd ST ` SW 4th S W t w z SW 4th ST S > a Q S U O 1 a ¢ s SW 5th ST P� w 9 m OD � w � N Sa P, Z w s 4� v Ln + SW 6 h S Q ti v H 4- 3 n N ¢ Z SW 7th S s L Z (h s E 8 ST F W 8th ST �> O 3 a SE 9th ST Ir r ¢ a SW 9th ST 1 U 41 SW loth ST N s g SW loth ST 3 ti s + 41 4� Ln SW llth ST m m rn a 30 SW llth ST SURVEYOR'S CERTIFICATION : I HEREBY CERTIFY THAT TH15 SPECIFIC PURPOSE SURVEY WAS PREPARED UNDER MY DIRECT SUPERVISION AND THAT IT 15 TRUE AND CORRECT TO THE BEST OF MY KNOWLEDGE AND BELIEF. Carlos E Alonso Digitally signed by Cados E Alonso Date: 2021.08.0610.02.23-04'00' CARLO5 E. ALON50 PROFESSIONAL SURVEYOR AND MAPPER No. GGG9 STATE OF FLORIDA NOT VALID WITHOUT THE SIGNATURE AND THE ORIGINAL RAISED SEAL OF A FLORIDA LICENSE SURVEYOR AND MAPPER. LICENSED BUSINESS No.2439 PROJECT NUMBER: 16-659 MANUEL G.VERA AND ASSOCIATES, INC. TYPE of PROJECT: SPECIFIC PURPOSE SURVEY ENGINEERS -SURVEYORS � MAPPERS PROJECT NAME: DOSE MAKTI PARK 139GO S.W. 47th 5T. MIAMI, FLORIDA 331 75 DATE: 04-26-2021 SCALE SHEET PHONE: (305) 22 1 -G2 10 e-mail: 5nuin@mcjvera.com DRAwN BY: DH N.A. I of 5 SPECIFIC PURPOSE SURVEY KEY MAP: RIPARIAN LINE 1B N. SUMERGED LANDS 2B LEASE AREA S.W. 2nd W a STREET 9 1922 US HARBOR LINE 3B 1 4B \ \ v' T 1922 SHORE c� LINE 6B 'B p O BISCAYNE BAY EXISTING MHwL 6M a1M ) �� AQUATIC PRESERVE �P 2M 2 N � � 4M 3M 2 S.W. 3rd Z STREET Q �� y 2H 3 2 1H 0 Z 1 1Mc 3L B 0 E q RIPARIAN LINE w Q 6 )8 aB 't 1L NOT a PLRBOUNDARY of THE a BOUNDARY SURVEY B T A FDOT LEASED AREA `n S.W. 4th STREET a� 3 9saF0 10 9 8 i 6 y 2`s 1G m L z zG o tix Nm°O MAP OF MIAMI DADE CO. FLA. .t 3G P.B. B, PG. 41) 14 ti Zg 0 BLOCK 28' ?� O RIVERSIDE WATERFRONTS ]1 12 ]3 O Oa (P.B. 25, PG. 72) O NOT A PART OF THE BOUNDARY SURVEY 4G O 1 19 20 S.W. 5th STREET w MAP OF MIAMI DADE CO. FLA.z (P. B. B, PG. 41 w BLOCK 3T5 - 1 ' 2 Q 10 9 3 > MAP OF f.IIFIT- 6 DADE f+l NOT A PART 7 � q CO. OF HE U FDOT LEASED AREA m (P.B. B, PG. 41) OUNIASURVEY - O BLOCK 37, ul 12 V U BASEBALL FIELD O U - _ 17 18 19 29 S.W. 6th STREET LICENSED BUSINESS No.243e PROJECT NUMBER: i G-G53 SPECIFIC PURPOSE SURVEY ABBREVIATIONS: LEGEND: (M,) =DENOTES MEASURED (R.) =DENOTES RECORD MONUMENT LINE (L.D.) =DENOTES LEGAL DESCRIPTION CLi CENTERLINE M.H.W.L. =DENOTES MEAN HIGH WATER LINE R PROPERTY LINE UTIL. ESMT. =DENOTES UTILITY EASEMENT =DENOTES UTILITY CATCH BASIN UTIL. F.H. =DENOTES FIRE HYDRANT CURB INLET ENCRO. =DENOTES ENCROACHMENT rs DRAINAGE R/W =DENOTES RIGHT OF WAY ,. ,..' =DENOTES SIDEWALK O MANHOLE SANITARY SEWER SWK M.H. =DENOTES MAN HOLE iTEi) MANHOLE TELEPHONE =DENOTES SQUARE FEET. w SQ. j MANHOLE FIRE HYDRANT =DENOTES PARKWAY PKY =DENOTES LIGHT POLE O GUARD POLE L.P. PVMT =DENOTES PAVEMENT GUY ANCHOR =DENOTES CATCH BASIN C.B. SIGN =DENOTES WATER METER W M =DENOTES WATER VALVE ® CONCRETE W.V. =DENOTES SANITARY SEWER MANHOLE 7 LIGHT POLE S.S.M.H. =DENOTES TEMPORARY BENCH MARK WV T.B.M. X WATER VALVE =DENOTES FLORIDA POWER AND LIGHT FPL =DENOTES BELLSOUTH BOX EV ELECTRIC VALVE BELL S0. C.B.S. C & =DENOTES CONCRETE BLOCK & STUCCO =DENOTES CURB AND GUTTER G TREE =DENOTES CONCRETE CONC. FD.P.K. =DENOTES FOUND P.K. NAIL =DENOTES FOUND 1/2" IRON PIPE (NO I.D.) PALM FD.I.P. SET I.P. =DENOTES SET 1/2"(18" LONG) IRON PIPE WITH CAP NO. 2262 FD. N&D =DENOTES FOUND NAIL AND DISC SET N&D =DENOTES SET NAIL AND DISC 2262 T-XXX NUMBER OF TREE or PALM Fd DH =DENOTES FOUND DRILL HOLE P.O.B.=DENOTES POINT OF BEGINNING LINE TYPES: P.O.C. =DENOTES POINT OF COMMENCEMENT CHAIN LINK FENCE FD. =DENOTES FOUND WOOD FENCE BLDG =DENOTES BUILDING F.F.ELEV.: =DENOTES FINISH FLOOR ELEVATION CONCRETE WALL PG =DENOTES PAGE IRON FENCE p B =DENOTES PLAT BOOK GUARD RAIL np =DENOTES TYPICAL OVER HEAD WIRE SLLA =DENOTES SUBMERGED LANDS LEASE AREA RIGHT OF WAY LIMITS SURVEY TIE LINE r^ ......;.. CONCRETE PROPOSED LIVING SHORELINE PLANTER LICENSED BUSINESS No.2439 SPECIFIC PURPOSE SURVEY LEGAL DESCRIPTION SUBMERGED LAND LEASE AREA: A PORTION OF RIVERSIDE WATERFRONTS, ACCORDING TO THE PLAT THEREOF, AS RECORDED IN PLAT BOOK 25 AT PAGE 72 OF THE PUBLIC RECORDS OF MIAMI-DADE COUNTY, FLORIDA, LYING IN SECTION 1, TOWNSHIP 54 SOUTH, RANGE 41 EAST, MORE PARTICULARLY DESCRIBED AS FOLLOWS: COMMENCE ATTHE CENTERLINE INTERSECTION OF SW 4th AVENUE AND SW 2nd STREET; THENCE N 87°45'07" E ALONG THE CENTERLINE OF SAID SW 2nd STREET AND ITS EASTERLY EXTENSION, FOR A DISTANCE OF 25.00 FEET TO THE POINT OF INTERSECTION WITH THE EASTERLY RIGHT-OF-WAY LINE OF SAID SW 4th AVENUE; THENCE N 021453" W, ALONG THE EASTERLY RIGHT-OF-WAY LINE OF SAID SW 4th AVENUE FOR A DISTANCE OF 21.24 FEET TO THE POINT OF INTERSECTION WITH THE SOUTH LINE OF THE NORTH 2O.00 FEET OF THE SOUTH 1/2 OF LOT 2B AS RECORDED IN SAID PLAT BOOK 25 AT PAGE 72 OF THE PUBLIC RECORDS OF MIAMI-DADE COUNTY; THENCE N 87°43'50" E ALONG SAID SOUTH LINE OF THE NORTH 2O.00 FEET OF THE SOUTH 1/2 OF LOT 2B AS RECORDED IN SAID PLAT BOOK 25 AT PAGE 72 OF THE PUBLIC RECORDS OF MIAMI-DADE COUNTY FOR A DISTANCE OF 150.31 FEET; THENCE S 00°4748" E FOR A DISTANCE OF 5.65 FEET TO THE POINT OF BEGINNING OF THE HEREINAFTER DESCRIBED PARCEL; THENCE S 09°19'06" E FOR A DISTANCE OF 26.58 FEET; THENCE N 86°45'58" E FOR A DISTANCE OF 5.74 FEET; THENCE S 15°28'20" E FOR A DISTANCE OF 115.29 FEET TO THE POINT OF INTERSECTION WITH THE 1951 SHORELINE OF THE MIAMI RIVER AS TAKEN FROM AN AERIAL IMAGE; THENCE ALONG THE PREVIOUSLY DESCRIBED 1951 SHORELINE OF THE MIAMI RIVER FOR THE FOLLOWING TWO (2) COURSES; (1) THENCE N 29°58'24" W FOR A DISTANCE OF 35.63 FEET; (2) THENCE N 24°02'21" W FOR A DISTANCE OF 101.78 FEET; THENCE N 03°5740" W FOR A DISTANCE OF 10.08 FEET; THENCE N 80°40'54" E FOR A DISTANCE OF 19.42 FEET TO THE POINT OF BEGINNING. CONTAINING 1,904 SQUARE FEET MORE OR LESS SURVEYOR'S REPORT: THIS IS NOT A BOUNDARY SURVEY, THIS IS A SPECIFIC PURPOSE SURVEY TO DELIMIT THE SUBMERGED LAND LEASE AREA. THIS IS A FIELD SURVEY. THIS SPECIFIC PURPOSE SURVEY WAS PREPARED IN ACCORDANCE WITH THE STANDARDS OF PRACTICE SET FORTH BY THE FLORIDA BOARD OF LAND SURVEYORS AND MAPPERS PURSUANT TO SECTION 472.027 FLORIDA STATUTES AND TO CHAPTER 5J-17 OF THE F.A.C. BEARINGS ARE BASED ON THE STATE PLANE COORDINATE SYSTEM, FLORIDA EAST ZONE, NORTH AMERICAN DATUM OF 1983, ADJUSTMENT OF 2011 (NAD83/11). A BEARING OF N 02°1453" W WAS ESTABLISHED ALONG THE CENTERLINE OF SW 4TH AVENUE. NO EXCAVATION WAS MADE AS TO SHOW THE SUBJECT PROPERTY IS SERVED BY UTILITIES.SUBSURFACE UTILITIES, INCLUDING, BUT WITHOUT LIMITATION TO PIPES, WIRES, VAULTS, BOXES, DRAIN TILES, VOIDS, CABLES AND OTHER MATERIALS ANCILLARY TO THE DELIVERY AND/OR DISPOSAL OF WATER, WASTEWATER, SEWAGE, ELECTRICITY, GAS, TELEPHONE SERVICE, CABLE TELEVISION OR AS THEY MAY EXIST WITHIN, UPON, ACROSS OR ABUTTING THE SUBJECT PROPERTY WERE NOT PHYSICALLY LOCATED. OTHER SUBSURFACE STRUCTURES AS THEY MAY EXIST WITHIN, UPON, ACROSS OR ABUTTING THE SUBJECT PROPERTY WERE NOT LOCATED UNLESS OTHERWISE SHOWN ON THE SURVEY MAP OR ACCOUNTED FOR IN THE PRECEDING STATEMENT OF THIS SECTION.THIS NOTICE IS REQUIRED BY THE STANDARDS OF PRACTICE FOR LAND SURVEYING IN THE STATE OF FLORIDA," PURSUANT TO RULE 61 G17-6 OF THE FLORIDA ADMINISTRATIVE CODE. THE SURVEY MAP IS INTENDED TO BE DISPLAYED AT THE STATED GRAPHIC SCALES IN ENGLISH UNITS OF MEASUREMENT AS DEPICTED ON THE SURVEY MAP.ATTENTION IS DIRECTED TO THE FACT THAT SAID SURVEY MAP MAY BE ALTERED IN SCALE BY REPRODUCTION AND MUST BE CONSIDERED WHEN OBTAINING SCALED DATA. THERE MAY BE UNDERGROUND UTILITIES CROSSING THIS PROPERTY. UTILITY COMPANIES MUST BE NOTIFIED BEFORE ANY DIGGING OR CONSTRUCTION BEGINS ON THIS PROPERTY. MEAN HIGH WATER ELEVATION (+)0.01' (NAVD88) WAS PROVIDED BY THE DEPARTMENT OF ENVIRONMENTAL PROTECTION (DEP). 1922 HARBOR LINE TAKEN FROM RECORDED PLAT WATERSIDE RIVERFRONT AS RECORDED IN PLAT BOOK 25 AT PAGE 72 IS FOR INFORMATION PURPOSE ONLY. THE DEPARTMENT OF ENVIRONMENTAL PROTECTION RECOMMENDED TO USE THE 1922 HARBOR LINE PROVIDED BY THE US ARMY CORPS OF ENGINEERS.SEE SKETCH OF SURVEY. DATE OF FIELD SURVEY: 03/03/20 CERTIFIED TO -BOARD OF TRUSTEES OF THE INTERNAL IMPROVEMENT TRUST FUND OF THE STATE OF FLORIDA -CITY OF MIAMI LICENSED BUSINESS No.2439 N87'43'32"E o S.W. 2nd STREET SPECIFIC PURPOSE SURVEY N - N M_ \ � �O N G G � fV N CD z 7.0'617.94' N 87'45'07" E 25.00' a m ai N I � 15.0 25.00 I I I m z I 0 o Lu m � I a I4-J a 7j- N 0 w w = w N F O � oLu of w w w w z o O o -N CD 0,0 Lr)w O w = z = 15031' N 87'43'50" E N PROPOSED _ m INCH 5.48' TO RIPARIAN LINE TO THE NORTH TW +6.00' \ 1 BW -9.00' . E Fi1PPR p� \ S00 47'48' \ 5.65' E\ \ N O w - P.O.B._ 1 W E SLLA \ � S \ 15.00 1 1 \ N \ 1 0 m \p m w z Lu Q iw w W w LL 2w z0 s d cc O w 'n y W N � W w 1 � O J�O --- - - - - -- -- -- �- LICENSED BUSINESS No.2439 \ \ O \ r� -n O O 1 �n \ NS O \ �➢ 1 Om t 20,00 �m 1 447.61' TO RIPARIAN LINE TO THE SOUTH